5.3.14 Cooling the X Axis Motors
5.3.15 Cooling the Y Axis Motors for Placement Area 1/2
To cool the Y axis motors, an additional pneumatic system is integrated, which sucks the air from the
environment, compresses it in a compressor and conducts its through a hose system to each of the Y
axis motors.
The motor coil temperature is monitored. If this exceeds 110°C, a message will appear on your screen.
This simple cooling system is installed to ensure that the Y axis does not overheat.
5-34: Cooling system X axis motor
The exhaust air from the vacuum generator
(pressure control valve) of the C&P head is used
to cool the X axis motors.
Legend
1. Air distributor
2. Air tube for cooling the X axis
3. Hose via the distributor to the pneumatic unit
4. Silencer
5-35: Cooling system Y axis motor
Legend:
1. Compressor, located in main unit
2. Startup control for the compressor
3. Y axis motor gantry 4/3
4. Y axis motor gantry 1/2
5. air hose for air supply used for cooling the
linear motor
Energy and Compressed Air Supply
Cooling the Y Axis Motors for Placement Area 1/2 Room for Your Sketches and Notes
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
207
5.4 Room for Your Sketches and Notes
Energy and Compressed Air Supply
Room for Your Sketches and Notes Cooling the Y Axis Motors for Placement Area 1/2
Student Guide (FSE) SIPLACE X Series and X4I
Energy and Compressed Air Supply Edition 01/2009 EN
208