00196044-05 - sg x und x4i fse_en.pdf - 第626页
Measuring Equipment and Tools Calibration Tool [03010565-01] Scope of Delivery S tudent Guide (FSE) SI PL ACE X Series and X4I Measuring Equipment and T ools Edition 01/2009 EN 630 15.1 1 Calibration T ool [03010565-01] …

Measuring Equipment and Tools
Scope of Delivery Adjustment Aid for C&P DLM [00327005-01]
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Measuring Equipment and Tools
629
15.10 Adjustment Aid for C&P DLM [00327005-01]
Complete set: Art. No. 00327005-01
1. Gauge for star [00326164-01]
2. Test probe 1.4 mm [00326160-01]
3. Test probe 1.5 mm [00326161-01]
4. Test probe 1.6 mm [00326162-01]
5. Test probe 1.0 mm [00376656-01]
6. Distance gauge [00325445-01]
Measurement tools Application type
Gauge for star Setting the zero point correction for the star
Test probe 1.4 mm Setting the distance between the DP station incremental encoder and the glass for
the sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance from the Z axis light barrier down to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star

Measuring Equipment and Tools
Calibration Tool [03010565-01] Scope of Delivery
Student Guide (FSE) SIPLACE X Series and X4I
Measuring Equipment and Tools Edition 01/2009 EN
630
15.11 Calibration Tool [03010565-01]
15.12 Calibration Tool [003034148-xx]
Application:
The calibration tool [003010565-xx] is used for
calibration of the C&P6/12, CPP, P&P and
Twin Head (for X-series) placement heads.
Application:
The calibration tool [003034148-xx] is used for
the C&P20A placement head.
It is used in X series machines for calibration
of the component camera SST23.

Measuring Equipment and Tools
Scope of Delivery Calibration Nozzle for Twin Head [03008862-xx]
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Measuring Equipment and Tools
631
15.13 Calibration Nozzle for Twin Head [03008862-xx]
15.14 Setting Gauge for Board Clamping [00369202-01]
15.15 Setting Gauge for Conveyor Laser Light Barrier
Application:
The calibration nozzle is used to calibrate the
D axis of the Twin Head or P&P head.