00196044-05 - sg x und x4i fse_en.pdf - 第496页
Calibration Additional Functions Head Exchange SIPLACE X S tudent Guide (FSE) SI PL ACE X Series and X4I Calibration Edition 01/2009 EN 500 X Click on Head EEPROM data (1) . The data for the head will be read out of the …

Calibration
Head Exchange SIPLACE X Additional Functions
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Calibration
499
12.6.2 Head Exchange SIPLACE X
Head data
1. Selection button, BIOS application1/2
2. Shows the status of the individual subsystems.
3. Update information about the number of
subsystems which still have to be
downloaded.
4. Starts the download.
After changing the head hardware, the new head
data needs to be made available from the head
EPROM of the software.
X Switch the machine on.
X Select the user level
Service (customer)
(1).
X Switch over to the menu
Check sensors and
functions
(2).
X Click on the
Check sensors and functions of
specific components
(3).
X Click on
CP20 head, gantry x
button for the
gantry concerned (4).

Calibration
Additional Functions Head Exchange SIPLACE X
Student Guide (FSE) SIPLACE X Series and X4I
Calibration Edition 01/2009 EN
500
X Click on
Head EEPROM data
(1). The data
for the head will be read out of the EEPROM
and written in the machine data.
X For checking or manual entries, proceed as
follows.
X Select the Z axis/star axis (1).
X Select
Zero correction data
(2).
This is where the axis data (Z and star axes) can
be written from the head EPROM to the machine
data. You can also write the Z and star axis data
from the machine data to the head EPROM.
X In the
Zero correction data
(1) select the line
Zero point correction
(2).
X ;Move the value out of the head EPROM and
into the machine data (3).
X Select
Write head & machine data
(4).
X The arrow button (5) takes you back one menu
level.

Calibration
Zero Point Correction for Z and Star Axes Additional Functions
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Calibration
501
12.6.3 Zero Point Correction for Z and Star Axes
NOTE:
The function Calibrate zero point correction must be carried out after certain service work to the
C&P20A head.
X This work may only be performed by Siemens service technicians.
This function can be performed with the user level
(1)
Siemens service
.
A referenced head (star, Z axis) is a precondition.
X Switch over to the menu
Check sensors and
functions
(2).
X Click on
Calibrate zero point correction
(3).
NOTE:
This function is only available for the
C&P20A head.