00196044-05 - sg x und x4i fse_en.pdf - 第596页

MTC2 MTC2 Calibration and Settings Machine Data S tudent Guide (FSE) SI PL ACE X Series and X4I MTC2 Edition 01/2009 EN 600 14.3.6 Machine Data 14.3.6.1 General machine p arameters Software vers ion: Date 11.2004 Serial …

100%1 / 632
MTC2
Converting the power supply MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
599
14.3.5.3 Voltage distributor terminal X01
14.3.5.4 Motor Circuit Breaker
14-61: Voltage distributor terminal X01
Legend
1. Bridges on the voltage distributor terminal X01
X Removing the three bridges between 2-3, 6-7
and 10-11.
X Connect the six bridges between 1-2, 3-4, 5-6,
7-8, 9-10 and 11-12.
14-62: Motor Circuit Breaker
Legend
1. Rotary regulator of the motor protection switch
X It is always 3.5 A.
MTC2
MTC2 Calibration and Settings Machine Data
Student Guide (FSE) SIPLACE X Series and X4I
MTC2 Edition 01/2009 EN
600
14.3.6 Machine Data
14.3.6.1 General machine parameters
Software version: Date 11.2004
Serial number, MTC2: 214
Delta fiducial transfer position: 10000
14.3.6.2 Machine parameters for tower 1
Machine parameters for the lifting axis on tower 1
Positions
Offset, zero position: -500.300 mm
Position of operator removal position, cassette 1: 0 mm
Position of operator removal position, cassette 2: 103.150 mm
Position of operator removal position, cassette 3: 206.250 mm
Position of operator removal position, cassette 4: 309.450 mm
Position of operator removal position, cassette 5: 412.600 mm
Position of WTC removal position, cassette 1: 28.300 mm
Position of WTC removal position, cassette 2: 131.500 mm
Position of WTC removal position, cassette 3: 234.500 mm
Position of WTC removal position, cassette 4: 337.800 mm
Position of WTC removal position, cassette 5: 440.950 mm
Minimum position: -3.233 mm
Maximum position: 573.472 mm
Service position: 165.000 mm
Travel parameters
Default speed, WTC: 50
Default acceleration, WTC: 50
Acceleration, lower threshold value: 1
Acceleration, upper threshold value: 50
Acceleration, axis command: 50
Acceleration, axis command: 50
NOTE:
The machine parameters listed are only an example of a data record. The individual values can
be different for each MTC2 .
WARNING:
Incorrectly set machine data can result in a crash between the lifting and feed axes or at the limit
positions of these axes.
MTC2
Machine Data MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
601
Machine parameters, feed axis, tower 1
Positions
Position of WTC removal position, cassette 1: 0 mm
Position of WTC removal position, cassette 2: -0.180 mm
Position of WTC removal position, cassette 3: -0.220 mm
Position of WTC removal position, cassette 4: 0.230 mm
Position of WTC removal position, cassette 5: -0.320 mm
Offset, zero position: -11.350 mm
Component transfer position: 646.500 mm
Minimum position: -3.389 mm
Maximum position: 652.548 mm
Service position: 249.999 mm
Travel parameters
Default speed, moving WTC out: 150
Default speed, moving WTC in: 150
Default acceleration, WTC: 100
Acceleration, lower threshold value: 1
Acceleration, upper threshold value: 150
Acceleration, axis command: 50
Acceleration, axis command: 50