Energy and Compressed Air Supply
DC/DC Converter Vision Section 2 Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
185
5.2.7 DC/DC Converter Vision Section 2
This DC/DC converter is only used for generating 48 V for P&P camera illumination as well as the power
distribution for PCB camera (5/24V) and component camera (24V).
5-11: DC/DC converter section 2
5.2.7.1 Power Supply Tape Cutter
The tape cutters are arranged both in parallel and serial mode. The tape cutters in sector 2 and sector
3 are serial, tape cutters in sector 1 and sector 4 are also arranged in serial mode.
5-12: Power supply for tape cutter
Energy and Compressed Air Supply
Power supply DC/DC Converter Vision Section 2
Student Guide (FSE) SIPLACE X Series and X4I
Energy and Compressed Air Supply Edition 01/2009 EN
186
5.2.7.2 Voltage Supply for Hood Fans
The increase in placement performance, optimization of travel paths, rotated gantry and the overlapping
of individual axes leads to increased heat generation inside the machine. This heat can affect the
placement accuracy and the MTBF times. For this reason, each machine hood has been equipped with
four fans for cooling the processing areas.
5-13: Voltage Supply for Hood Fans
The fans are supplied with 24V from the computer unit by the DC/DC converter and are switched via the
safety circuit.
Energy and Compressed Air Supply
Safety and Signaling Circuit Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
187
5.2.8 Safety and Signaling Circuit
5.2.8.1 Emergency STOP Circuit (Safety Circuit)
Following contacts are switched in serial and build the safety loop:
4 protective cover switches (main cover).
conveyor cover switch.
Contact on changeover table
The emergency STOP button may not be pressed (input and output conveyors)
5-14: Safety loop
Description of emergency STOP circuit:
When the emergency STOP circuit is closed, there is 24 V present at K5, contact 3. A further 24 V signal
is sent as
EMERGENCY STOP loop OK
Sent to each CAN I/O module, indicating that the covers are
all closed and that the changeover tables are connected.