00196044-05 - sg x und x4i fse_en.pdf - 第502页
Calibration Additional Functions Fast Head Exchange S tudent Guide (FSE) SI PL ACE X Series and X4I Calibration Edition 01/2009 EN 506 12.6.5 Fast Head Exchange See also: J 13 Head Modularity [ J 517] 12.6.5.1 General …

Calibration
Configuring the Conveyor Additional Functions
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Calibration
505
X Select the fixed conveyor side (1) (
Left
,
Right
,
Outer
).
X Select the position of the fixed conveyor side
(2).
X Select the conveyor mode (3).
X Click on
Adjust configuration
(4) button to
adjust the conveyor sides.
NOTE:
This menu appears for both single and
dual conveyors.
X Use the
User Defined
button to set the fixed
conveyor side.
The values are Y values, referring to the
machine coordinate system.
The outer sides of the conveyors are the standard
fixed sides for quad lane conveyor configurations.

Calibration
Additional Functions Fast Head Exchange
Student Guide (FSE) SIPLACE X Series and X4I
Calibration Edition 01/2009 EN
506
12.6.5 Fast Head Exchange
See also:
J
13 Head Modularity [
J
517]
12.6.5.1 General
The fast head exchange is a new function which enables you to change a placement head in 15 minutes.
The first version of this function with software 702 only supports rapid head changing between placement
heads of the same type.
Requirements:
SW 702 and the latest eSW versions
The placement heads in the machine have the calibration data stored in the EEPROM.
Fast head changing is not possible if the CPP with stationary camera is to be changed.
Fast head changing is not possible for the Twin Head.
If these requirements are fulfilled, the heads can be changed and will be ready for operation after a brief
calibration run.
This brief calibration procedure covers the following points:
Calibration of the component camera on the head (determination of head rotation angle to board
camera)
Determination of the segment offset with the reference segment (determination of the global
segment offset (head offset) to the board camera and the positioning over all stationary cameras)
12.6.5.2 Hardware Changes
Head plate with hook, placement head with eyelet
Screws as torx screws
Screws are fastened to head with loss proof fixture
Reduction of compressed air connections on compressed air distributor, T piece between pressure
control valve and return unit
NOTE:
These hardware changes apply only to C&P20A and CPP heads.

Calibration
Fast Head Exchange Additional Functions
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Calibration
507
12.6.5.3 Software Changes
A differentiation can be made between a complete head exchange and a spare parts replacement on
the head, and between the precalibrated heads (data in EEPROM) and calibrated heads in the machine
(no data in EEPROM).
When using calibrated heads in the machine, the
head data needs to be written to the EEPROMs (1)
after performing a software update to SW702.
These placement heads are now prepared for the