00196044-05 - sg x und x4i fse_en.pdf - 第576页

MTC2 MTC2 Calibration and Settings SITEST Calibration Flow Charts S tudent Guide (FSE) SI PL ACE X Series and X4I MTC2 Edition 01/2009 EN 580 14-44: Overview "calibration of feed axes 1/2"

100%1 / 632
MTC2
SITEST Calibration Flow Charts MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
579
2b. Transfer position of the Tower 2 WTC
Select
Teach transfer position
, the tray will move out and come to a stop approx. 5 mm before the feed
axis ends.
X Open the cover.
X Move the tray in the direction of the machine and stop so that the plastic edge of the tray comes into
line with the frame of the feed axis.
X You must do this in one step.
If the tray has been moved out with the feed axis, push it back in again and try to align it with the feed
axis frame in one step. This eliminates the tolerance between the driver and the tray gap and means
that you do not need to enter a pickup offset in the programming system.
During the production the trays move a different way to her pick up position but the Y Position of the
machinen (pick up postion) of both trays is the same.
ATTENTION:
If you have confirmed the calibration with
OK
in this situation, you will have calculated an
incorrect transfer position, which will lead to an incorrect pickup position for the Twin head.
14-43: Transfer position JEDEC tray
Legend
1. Plastic edge of the WTC
2. Edge of the frame from the MTC
MTC2
MTC2 Calibration and Settings SITEST Calibration Flow Charts
Student Guide (FSE) SIPLACE X Series and X4I
MTC2 Edition 01/2009 EN
580
14-44: Overview "calibration of feed axes 1/2"
MTC2
SITEST Calibration Flow Charts MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
581
14-45: Overview "calibration of feed axes 2/2"