Operational Safety
Switches and Buttons on the Placement Machine Safety Features
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Operational Safety
43
2.4.1.3 Function Description
Main power switch in the OFF position
The main power switch disconnects the three phases L1, L2, and L3 from the power supply.
Cable connection terminals L1, L2, and L3 of the Q1 main power switch
Z1 line filter
Service socket X102
F1 automatic circuit breaker for the service socket
The color of all individual wires, which still carry potentially lethal voltages even if the main power
switch is switched off, is brown.
– Death, serious injury or considerable damage may result if these automatic placement systems
are handled incorrectly.
– Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1) and the applicable regulations in your own country.
– The safety door to the power supply must ONLY be opened by appropriately qualified and
trained personnel.
EMERGENCY STOP pushbutton, latching, with override protection to EN 418
The emergency stop button is red and latches in the ON position when pressed. When you press the
emergency stop button, the switching contact of the emergency stop circuit opens and the protective
contactor combination (SSK K6) trips. The intermediate circuit voltage (250 VDC) for the gantry axes and
the intermediate circuit voltage (145 VDC) for the star axes is switched off. The servo amplifiers for the
DP and Z axes are still supplied with 40 VDC. The signaling contact of the EMERGENCY STOP button
will open and the message
EMERGENCY STOP operated
will be shown on the screen. The following
assemblies will be disabled:
PCB conveyor
PCB clamping
Width Adjustment
PCB stopper
Empty tape cutter.
See also:
J
2.4.3.1 Safety Circuit Function [
J
45]
DANGER:
The following components still carry potentially lethal voltages even if the main power switch is
switched off:
NOTE:
Placement will be interrupted and can then be continued or canceled once the machine is
functional again.

Operational Safety
Safety Features Position of Pushbutton for Docking and Undocking the Component Trolley
Student Guide (FSE) SIPLACE X Series and X4I
Operational Safety Edition 01/2009 EN
44
2.4.2 Position of Pushbutton for Docking and Undocking the Component Trolley
2-19: Pushbutton for docking and undocking the component trolley
Legend
1 Pushbutton for docking and undocking the component trolley

Operational Safety
Safety and Signaling Circuit Safety Features
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Operational Safety
45
2.4.3 Safety and Signaling Circuit
2.4.3.1 Safety Circuit Function
The following conditions must be fulfilled in order to start and operate the placement machine:
All four component trolleys must be docked in and connected.
All protective covers must be closed.
The two cover flaps over the PCB conveyor must be closed.
Both emergency stop buttons must be released.
The cover flaps (option) over the feeder modules must be closed.
The minimum operating pressure must have been reached.
The "software enable" signal must be active. This ensures that the safety circuit is closed.
The power supply must be sending 24 V to the Start buttons and the protective contactor
combination.
If one of the Start buttons is now pressed, the protective contactor combination SSK K6 will switch
and activate the following components:
– 250 VDC intermediate circuit voltage for the servo amplifiers for the gantry axes
– 145 VDC intermediate circuit voltage for the star axes
– The axis unit receives a "servo enable" signal for the servo amplifier
– 48 V for X tables (34 V for S tables, not for X4I) – operating voltage is switched through to
component trolleys
– 24 VDC operating voltage is switched to the used tape cutters.
– The PCB conveyor control receives the enable signal for the PCB clamping, the PCB stopper
and the lifting table control.
The machine is then ready for use.