Head Modularity Calibration Head Modularity Twin Head to CPP/C&P S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Head Modularity 525 13.5 Head Modularity T win Head to CPP/C&P 13-5: Procedure fo…

100%1 / 632
Head Modularity
Head Modularity CPP/C&P to Twin Head Calibration
Student Guide (FSE) SIPLACE X Series and X4I
Head Modularity Edition 01/2009 EN
524
13.4 Head Modularity CPP/C&P to Twin Head
13-4: Procedure for head exchange CPP/C&P to TwinHead
Head Modularity
Calibration Head Modularity Twin Head to CPP/C&P
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Head Modularity
525
13.5 Head Modularity Twin Head to CPP/C&P
13-5: Procedure for head exchange TwinHead to CPP/C&P
Head Modularity
Head Modularity C&P20A to CPP Head Calibration
Student Guide (FSE) SIPLACE X Series and X4I
Head Modularity Edition 01/2009 EN
526
13.6 Head Modularity C&P20A to CPP Head
Preparation:
X Place the nozzles from all heads, even those which were not exchanged, in the nozzle changer.
X Back up the machine data with
Save machine data
.
X Switch off the machine.
X Dismantle the C&P20A placement head.
Protect the component sensor by fitting the red rubber hose onto the prisms and removing the
changeover table.
Remove the black compressed air hose from the distributor and from the head.
Loosen the flat ribbon cable from the head adapter but leave it on the head.
X Prepare the head plate as follows.
Preparing the X motor plate (head plate)
X Remove the cable holders (1).
NOTE:
After conversion, a new autoconfiguration file will be compiled when the machine is switched