00196044-05 - sg x und x4i fse_en.pdf - 第64页

Overview Overview of Components Axis Unit with A364 S tudent Guide (FSE) SI PL ACE X Series and X4I Overview Edition 01/2009 EN 64 3.2.5.2 Axis Controller Board A364

100%1 / 632
Overview
Axis Unit with A364 Overview of Components
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Overview
63
3.2.5 Axis Unit with A364
The axis unit contains the servo boards, axis controller boards, power supplies (+/-15V,+5V) and ballast
circuit. The flexible axis unit is equipped with the correct servo and axis boards for the machine type and
head configuration concerned. Depending on the machine type, there will be either one or two axis units
in the machine.
See also:
J
13.9 Slots in the Axis unit [
J
533]
3.2.5.1 Axis Unit A364
See also:
J
13.9.1 Axis Unit A364 [
J
533]
3-13: Configuration of axis unit X4I with C&P20A heads
Legend
1. Power supply +/- 15, +5 V
2. Ballast circuit, only in axis unit PA2
3. Power supply +/- 15V
4. Fan unit (blows downwards)
5. Axis card A364 for gantry 1/2
6. Axis card A364 for gantry 4/3
7. Servo amplifier X axes
8. Servo amplifier Y axes
9. Brake board for each X axis and Y axis
10. Servo star axis (2x)
11. Servo Z axis (2x)
12. DC/DC converter DP drives (2x)
13. Placement area 1 gantry 1 (top half)
14. Placement area 1 gantry 4 (bottom half)
Overview
Overview of Components Axis Unit with A364
Student Guide (FSE) SIPLACE X Series and X4I
Overview Edition 01/2009 EN
64
3.2.5.2 Axis Controller Board A364
Overview
Changeover Table Components Overview of Components
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Overview
65
3.2.6 Changeover Table Components
SIPLACE X machines with SW70x only support the new generation of X feeders and X component
changeover tables. This changeover table does not have any electronic assemblies, such as the
communication unit for feeder supply and control in the previous tables. The power supply for the feeders
is without contact, via an inductive interface on the docking unit, directly to the feeders. Control and
communication between the feeder control unit (FCU) and the feeders is provided via two optoelectronic
channels (light conductors). The FCU is connected to the computer unit in the machine via the machine
CAN Bus. Only X tables can be used on the machines.
3.2.6.1 Docking and Undocking
Each X feeder table has 40 slots for 8 mm X feeders, giving a total capacity of 160 individual tracks on
4 changeover tables.
3-14: Shows the button for docking and undocking changeover tables
Legend
1. Button for docking and undocking changeover
tables
T = transport direction
The changeover table is automatically docked at
the machine, with two pneumatic cylinders. For
docking, the changeover table is moved up to the
docking unit, the hood is closed and the button is
pressed. For undocking, the cover is opened and
the button is pressed again.
NOTE: From software 70x
X machines from software 70x only support X tables.
NOTE: X4I
Due to the rotated gantries, there are only 34 tracks available at locations 2 and 4 of the X4I.