MTC2 MTC2 Calibration and Settings Adjustments feed axes S tudent Guide (FSE) SI PL ACE X Series and X4I MTC2 Edition 01/2009 EN 592 X Set the minimum position of the limit switch above its limit switch ho lder until the…

MTC2
Adjustments feed axes MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
591
X Turn the adjusting screw of the drive belt as far as it will go. Before doing this you will need to loosen
the lock nut.
X Loosen the two clamping screws on the mounting block of the motor.
X Use the adjusting screw to raise the belt tension (by turning in a clockwise direction) or lower it (by
turning in an anticlockwise direction), until the nominal frequency is achieved. Tighten the lock nuts
each time you measure the belt tension.
X Firmly tighten the clamping screws and varnish them with red screw locking varnish.
X Check the belt tension again.
X Secure the cover plates and dock the MTC2 onto the SIPLACE station (see the User Manual).
X Check the zero offset of the feed axis -> „Teach the zero point", if you have changed the belt tension.
Checking and setting the toothed belt
X Carry out the relevant preparations (see Section ( Preparations
J
590 ) ).
X Measure the belt tension with the belt frequency measuring device in the following way:
X Make the toothed belt oscillate and measure the frequency - from the underside of the belt - in the
middle, between the outer deflection pulley and the first deflection pulley of the drive (for the
measuring point, see Section ( Tools and Equipment
J
590 ) ). Make sure that the driver is
approximately in its reference position.
X You must set the belt tension if the measured frequency deviates from the nominal value (70 Hz ± 2
Hz):
X Place the open-ended wrench on the setting flats of the eccentric axis.
X Loosen the clamping screw on the eccentric axis and maintain the position of the axis with the open-
ended wrench.
X Raise or lower the belt tension with the open-ended wrench (turning it in a direction depending on
the position of the eccentric axis), until the nominal frequency is achieved. Firmly tighten the
clamping screw each time you measure the belt tension and varnish it with red screw locking varnish.
X Check the belt tension again and make sure the screws are varnished with red screw locking varnish.
X Secure the cover plates and dock the MTC2 onto the SIPLACE station (see the User Manual).
X Check the zero offset of the feed axis -> „Teach the zero point", if you have changed the belt tension.
See also:
J
Tools and Equipment [
J
584]
14.3.4.2 Limit switch
Tools and accessories
1 set of Allen keys,
1 set of screwdrivers
Preparations
X Check the zero offset -> "Check the zero point".
X Check the transfer position -> "teach transfer position".
Setting the limit switches
X Move the feed axis into the transfer position (see Section ).
X Set the maximum position of the limit switch above its limit switch holder until there is a distance of
approximately 1 mm between the driver in the transfer position and the contact roller of the limit
switch.
X Move the feed axis into the zero position --> „Check the zero point“.
ATTENTION:
Before the limit switches are set, the zero offset and the transfer position must be checked (see
Section (14.3.2.2 Feed axis
J
575 ) ).

MTC2
MTC2 Calibration and Settings Adjustments feed axes
Student Guide (FSE) SIPLACE X Series and X4I
MTC2 Edition 01/2009 EN
592
X Set the minimum position of the limit switch above its limit switch holder until there is a distance of
approximately 1 mm between the driver in the zero position and the contact roller of the limit switch
(approximately 10 mm on tower 2).
X Check the feed axis end positions --> „Check and calibrate the travel range end positions".
14-54: Setting the maximum and minimum positions of the limit switches (shown here for tower 1)
Legend
1 Driver at the transfer position 5 Limit switch holder
2 Driver at the zero position 6 Contact area driver/limit switch at maximum
position
3 Limit switch maximum position with contact
roller
7 Contact area driver/limit switch at minimum
position
4 Limit switch minimum position with contact roller

MTC2
Adjustments feed axes MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
593
14.3.4.3 Light barriers
14-55: Light barriers on the feed axes
Legend
Tools and Equipment
Adjustment gauge, crash light barriers (03021679-01)
1 set of Allen keys
Preparations
X Move the feed axis into the zero position --> „Check the zero point“.
WARNING:
You may only check and calibrate the light barriers of the feed axis with the correct zero
positions, transfer positions and removal positions of the lifting and feed axes.
1 Handle sensor 3 Crash light barriers
2 WTC safety query