Communication and Control Reading the Board IDs out of the EEPROM Board IDs S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Communication and Control 161 4-61: Head interface board type recognition ID 0…

Communication and Control
Board IDs Reading the Board IDs out of the EEPROM
Student Guide (FSE) SIPLACE X Series and X4I
Communication and Control Edition 01/2009 EN
160
4-59: Subsystem control center
X Double-click on
Gripper
and the following dialog box will open:
4-60: Dialog head processor gripper
X Select the board to be checked
Off
then select the button
Get EEPROM.

Communication and Control
Reading the Board IDs out of the EEPROM Board IDs
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Communication and Control
161
4-61: Head interface board type recognition ID 01
X The ID will appear in the
memory cell
12, the ID 01 for the head interface C500.
4-62: Head adapter board type recognition ID 22 for the C&P20A head
4-63: C&P20A board ID 30
4-64: C&P20A board ID 31 vacuum sensor, hold circuit

Communication and Control
Board IDs Reading the Board IDs out of the EEPROM
Student Guide (FSE) SIPLACE X Series and X4I
Communication and Control Edition 01/2009 EN
162
Assembly ID 01 is digital pressure control valve
Assembly ID 02 is analog pressure control valve
4-65: Device number pressure control valve digital C&P20A
NOTE:
The digital pressure control valve (C&P20A) and the analog pressure control valve (Twin head)
do not have a board ID or it is currently 00.
NOTE:
Both pressure control valves will be recognized via a device number. This assembly ID is at
memory cell 14 in the EEPROM.