YAMAHA 报警资料.pdf - 第102页
Comparison Table ( English - Chinese ) VGOS V2.46STD R1.000 102 / 237 Copyright (C) 2009 Y amaha Motor Co.,Ltd. All Rights Reserved. Code Code Code Code Englis h Englis h Englis h Englis h Chinese Chinese Chinese Chinese…

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 101 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Ea03924 DISPENSE PROTECT
The data of dispense which is less than the appointed restriction
value exists. Check the quantity of dot(pre)dispense in board data,
and rate of nozzles in machine data.
Kind
1:Predispense 2:Dotdispense 3:Sequence
Dispense data No.
Quantity
Nozzle(Type)
Rate
Dispense Low Limit(ms)
涂胶量限制保
存在比指定的限制量低的涂胶量数据。
确基板程序中的正式()点胶数据的涂胶量,
以及机器置画面中使用点胶嘴的系数数据。
1:点胶 2:正式点胶 3:作流程
点胶数据 No.号
胶液量
使用 Nozzle(型)
系数
涂胶量限制(ms)
Ea03926 DATA CHECK ERROR
Wait Point(Y) exceeds Safety Pos.for Camera(Machine Y Axis).
Please set it to less than Wait Point(Y) minus Head Offset(Y).
Please correct the machine settings and read same Board data.
Wait Point(Y)
[Setting][Machine Data][Mechanical][Position]
Safety Pos.for Camera(Machine Y Axis)
[Setting][Machine Data][Tray Changer][Position]
Head Offset(Head1-2 Y)
[Setting][Machine Data][Head][Head Offset]
数据
待机位置(Y)超出了相机安全位置(主机 Y 坐)。
在相机安全位置(主机 Y 坐) - Head 偏移量(Head Y)内置。
正确置[机器置]画面后,重新入基板程序。
待机位置(Y)
[机器置][机器数据][机械坐][位置坐]
相机安全位置(主机 Y 坐)
[机器置][机器数据][托交器][位置坐]
Head 偏移量(Head 1-2 Y)
[机器置][机器数据][Head][Head 偏移量]
Ea03927 DATA CHECK ERROR
Discard Point(Y) exceeds Safety Pos.for Camera(Machine Y Axis).
Please set it to less than Discard Point(Y) minus Head Offset(Y).
Please correct the machine settings and read same Board data.
Discard Point(Y)
[Setting][Machine Data][Mechanical][Position]
Safety Pos.for Camera(Machine Y Axis)
[Setting][Machine Data][Tray Changer][Position]
Head Offset(Head1-2 Y)
[Setting][Machine Data][Head][Head Offset]
数据
弃位置(Y)超出了相机安全位置(主机 Y 坐)。
在相机安全位置(主机 Y 坐) - Head 偏移量(Head Y)内置。
正确置[机器置]画面后,重新入基板程序。
弃位置(Y)
[机器置][机器数据][机械坐][位置坐]
相机安全位置(主机 Y 坐)
[机器置][机器数据][托交器][位置坐]
Head 偏移量(Head 1-2 Y)
[机器置][机器数据][Head][Head 偏移量]
Ea03928 DATA CHECK ERROR
Dump Station(Y) exceeds Safety Pos.for Camera(Machine Y Axis).
Please set it to less than Dump Station(Y) minus Head Offset(Y).
Dump Station No.
Please correct the machine settings and read same Board data.
Dump Station(Y)
[Setting][Machine Data][Mechanical][Position]
Safety Pos.for Camera(Machine Y Axis)
[Setting][Machine Data][Tray Changer][Position]
Head Offset(Head1-2 Y)
[Setting][Machine Data][Head][Head Offset]
数据
弃位置(Y)超出了相机安全位置(主机 Y 坐)。
在相机安全位置(主机 Y 坐) - Head 偏移量(Head Y)内置。
弃站 号
正确置[机器置]画面后,重新入基板程序。
弃站(Y)
[机器置][机器数据][机械坐][位置坐]
相机安全位置(主机 Y 坐)
[机器置][机器数据][托交器][位置坐]
Head 偏移量(Head 1-2 Y)
[机器置][机器数据][Head][Head 偏移量]
Ea03929 DATA CHECK ERROR
Dipping Area(Y) exceeds Safety Pos.for Camera(Machine Y Axis).
Please set it to less than Dipping Area(Y) minus Head Offset(Y).
Dipping Station No.
Please correct the machine settings and read same Board data.
Dipping Area1-2(Y):Station Origin + Station Size
[Setting][Machine Data][Station][Dipping Station]
Safety Pos.for Camera(Machine Y Axis)
[Setting][Machine Data][Tray Changer][Position]
Head Offset(Head1-2 Y)
[Setting][Machine Data][Head][Head Offset]
数据
浸胶范(Y)超出了相机安全位置(主机 Y 坐)。
在相机安全位置(主机 Y 坐) - Head 偏移量(Head Y)内置。
浸胶站 号
正确置[机器置]画面后,重新入基板程序。
浸胶范(Y): 浸胶站原点 + 浸胶站尺寸
[机器置][机器数据][站装置][浸胶站]
相机安全位置(主机 Y 坐)
[机器置][机器数据][托交器][位置坐]
Head 偏移量(Head 1-2 Y)
[机器置][机器数据][Head][Head 偏移量]
Ea03930 DATA CHECK ERROR
Dispense Area on Dot Station(Y) exceeds Safety Pos.for Camera(Y).
Please set it to less than Dispense Area on Dot Station(Y)
minus Head Offset(Y).
Please correct the machine settings and read same Board data.
Dispense Area on Dot Station(Y):Station Datum(Y) + Size(Y)
[Setting][Machine Data][Station][Dot Station]
Safety Pos.for Camera(Machine Y Axis)
[Setting][Machine Data][Tray Changer][Position]
Head Offset(Head1-2 Y)
[Setting][Machine Data][Head][Head Offset]
数据
打点站上的涂胶范(Y)超出了相机安全位置。
在相机安全位置(主机 Y 坐) - Head 偏移量(Head Y)内置。
正确置[机器置]画面后,重新入基板程序。
打点站上的涂胶范(Y): 打点站基准(Y) + 尺寸(Y)
[机器置][机器数据][站装置][打点站]
相机安全位置(主机 Y 坐)
[机器置][机器数据][托交器][位置坐]
Head 偏移量(Head 1-2 Y)
[机器置][机器数据][Head][Head 偏移量]
Ea03931 A PARTS NUMBER IS ABNORMAL
The parts number registered with mount data is
abnormal. It occurs for the time when data after a
ASCII change is used just as it is. Please use the
board data of the line distribution and the
optimization execution ending.
Mount data
元件号异常
登在装数据上的元件号异常。
使用 ASCII 后的数据生。
使用已行生分配、最化的基板程序。
机器 号
元件 号
可以登在装数据上的元件号是 1-255。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 102 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Component number
The parts number by which registration is possible
is 1-255 in mount data.
Ea03934
The code scanning data exists more than a regulated number.
存在定数以上的条描数据
Ea03935 Please correct the mark data.(Pcb CodeScan)
Mark information corresponding to the Pcb CodeScan doesn't exist or,
there is no mark data for the code scanning.
Mark No
修改数据(基板条描)
不存在符合基板条描的信息,
或数据不是条描用数据。
号 号
Ea03936 Please correct the mark data.(Block CodeScan)
Mark information corresponding to the Block CodeScan doesn't exist or,
there is no mark data for the code scanning.
Mark No
修改数据(拼条描)
不存在符合拼条描的信息,
或数据不是条描用数据。
号 号
Ea03937 Please correct the Pcb CodeScan position.
The following axis coordinates are outside range of motion.
Axis name
Please correct positional coordinates of the Pcb CodeScan
in range of motion.
修改基板条描位置
以下的坐在工作范外。
名称
把基板条描的位置坐修改到工作范内。
Ea03938 Please correct the Block CodeScan position.
Please correct the Pcb CodeScan position.
Axis name
Please correct positional coordinates of the Block CodeScan
in range of motion.
修改拼条描位置。
以下坐在工作范外。
名称
把拼条描的位置坐修改到工作范内。
Ea03939 Please correct the mark data.(Pcb CodeScan)
The height of recognition of the Pcb CodeScan
is outside range of motion.
Please confirm mark information.
Mark No
修改信息
基板条描的高度在工作范外。
确信息。
号
Ea03940 Please correct the mark data.(Block CodeScan)
The height of recognition of the Block CodeScan
is outside range of motion.
Please confirm mark information.
Mark No
修改信息
拼条描的高度在工作范外。
确信息。
号
Ea03942 DATA CHECK ERROR
Force Calibration Station Position(Y) exceeds Safety Pos.for
Camera(Machine Y Axis).
Please set it to less than Force Calibration Station Position(Y).
Please correct the machine settings and read same Board data.
Force Calibration Station Position(Y)
[Setting][Specification Information][Force Control Specification]
[Basic/Convert]
Safety Pos.for Camera(Machine Y Axis)
[Setting][Machine Data][Tray Changer][Position]
程序
荷校正站基准(Y)超出了相机安全位置(主机 Y 坐)。
置在相机安全位置(主机 Y 坐)以内。
正确置[机器置]画面,并重新入基板程序。
荷校正站基准(Y)
[机器置][格信息][荷控制格]
[基本/]
相机安全位置(主机 Y 坐)
[机器置][机器数据][托交器][位置坐]
Ea03959 MACS DATA ERROR
There is wrong parameter in mark database for Wafer Thermal MACS.
because of following reasons;
- Mark Type is not "Wafer Fiducial".
- Algorithm Type is "PTRN ?".
Database No.
MACS 数据
晶片校正 MACS 用数据异常。
可能是因下列原因所致。
- 型没有置"晶片基准"。
- 型的置"匹配"。
数据 号
Ea03962 DATA CHECK ERROR
3A Correction cannot work under the current condition.
Please check the following items.
[Print][Board][Board Fiducial] must not be [Not Use].
程序
使用当前的置,无法行 3A 校正。
确以下目。
[印刷]-[基板]-[基板基准]的置不是[不使用]。
Ea03963 DATA CHECK ERROR
3A Correction cannot work under the current condition.
Please check the following items.
[Print][Board][Fiducial Type] must be [2 Points].
程序
使用当前的置,无法行 3A 校正。
确以下目。
[印刷]-[基板]-[基准型]的置[2 点]。
Ea03964 DATA CHECK ERROR
3A Correction cannot work under the current condition.
Please check the following items.
[Print][Mask][Mask Fiducial] must not be [Not Use].
程序
使用当前的置,无法行 3A 校正。
确以下目。
[印刷]-[网板]-[网板基准]的置不是[不使用]。
Ea03965 DATA CHECK ERROR
3A Correction cannot work under the current condition.
Please check the following items.
[Print][Squeegee][F.&B.Mask Offset] must be [Same Offset].
程序
使用当前的置,无法行 3A 校正。
确以下目。
[印刷]-[刮刀]-[往返目偏移量]的置[往返同一指定]。
Ea04000 <<<WARNING SENSOR ERROR>>>
Head down sensor or Lower Sensor is OFF in C-table.
Please check sensor and remove the cause of
this sensor being OFF.
If you don't remove the cause, it is impossible
<<<警告 感器异常>>>
在 C 工作台,出了[吸嘴下降状]。
下降端或第 1 下降区域的感器呈 OFF 。
感器,排除原因。
如不排除原因,不能行自运行。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 103 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
to start production.
Ea04001 <<<WARNING SENSOR ERROR>>>
Head down sensor or Lower Sensor is OFF in D-table.
Please check sensor and remove the cause of
this sensor being OFF.
If you don't remove the cause, it is impossible
to start production.
<<<警告 感器异常>>>
在 D 工作台,出了[吸嘴下降状]。
下降端或第 1 下降区域的感器呈 OFF 。
感器,排除原因。
如不排除原因,不能行自运行。
Ea04002 FLYING NOZZLE CHECK POSITION ERROR
Current Z position for Flying Nozzle check is abnormal.
Possible causes are:
1.Something prevents the movement to the target Z position
2.In [Machine Data]-[Mechanical]-[Position],
InitPosition of Z axis is wrong.
Head No.
行式交吸嘴位置异常
当前行式交吸嘴的高度异常。
1.因存在干物,而不能移到目的地。
2.[机器置]-[机械坐]-[位置坐]
的 Z 初始移异常。
Head 号 号
Ea04003 FLYING NOZZLE ERROR
The condition of Flying Nozzle can't be confirmed.
It has the possibility of the sensor mis-response.
行式交吸嘴异常
不能确行式交吸嘴的状。
感器的反可能失了。
修感器。
Ea04004 FLYING NOZZLE ERROR
The condition of Flying Nozzle can't be confirmed.
It has the possibility of the sensor mis-response.
行式交吸嘴异常
不能确行式交吸嘴的状。
感器的反可能失了。
修感器。
Ea04005 MACHINE STATUS ERROR
The unusual state of a machine was detected.
Please save a file required for investigation.
机器状异常
到不恰当的机器状。
保存有必要的文件。
Ea04006 OPTIMIZATION ERROR
Failed to start optimization.
Component data
Name
Information No
适当找
适当找始失了。
元件数据 号 名称
No
Ea04007 OPTIMIZATION ERROR
Failed to get the light status from vision system.
Component data
Name
Information No
适当找
从系取得照明条件失了。
元件数据 号 名称
No
Ea04008 OPTIMIZATION ERROR
Failed to get component information from vision system.
Component data
Name
Information No
适当找
从系取得元件信息失了。
元件数据 号 名称
No
Ea04009 OPTIMIZATION ERROR
Failed to send parameter to vision system.
Component data
Name
Information No
适当找
向系的参数送失了。
元件数据 号 名称
No
Ea04010 OPTIMIZATION ERROR
Failed to save image for vision system.
Component data
Name
Information No
适当找
向系保存像失了。
元件数据 号 名称
No
Ea04011 OPTIMIZATION ERROR
Failed to clear the memory of vision system.
Component data
Name
Information No
适当找
系的像内存清除失了。
元件数据 号 名称
No
Ea04012 IONIZER WARNING
An error occurred with the ionizer.
Please confirm a state of an ionizer,
and consult your distributor for further information.
离子生器警告
离子生器生了异常。
确离子生器的状,并向制造厂商咨。
Ea04014 FLYING NOZZLE EXCHANGE ERROR
Unable to exchange flying nozzles.
Please consult your distributor.
Head No.
行式吸嘴交超
行式吸嘴不能行交。
向生厂家咨。
Head No. 号
Ea04015 TIME OUT ERROR TO CONFIRM HEAD UP
When the parts bring back check is executed, the head up was not confirmed
though the head move up.
Nozzle down limit sensor is illegal.(Full Air Machine.)
Nozzle down lower end sensor is illegal. Or it was not possible to move the
movable head height.(Full Servo Machine.)
Please resume operations after confirming the state of each sensor
装上升确超
装后,在回元件的中,然装正在上升,
但却没能确到装的上升作。
可能是由下列原因造成。
下降域的感器异常。(全气机)
下降端的感器异常,或装没有移到足的高度。(全伺服机器)
确各感器和伺服装后,重新始运行。
工作台号