YAMAHA 报警资料.pdf - 第26页

Comparison Table ( English - Chinese ) VGOS V2.46STD R1.000 26 / 237 Copyright (C) 2009 Y amaha Motor Co., Ltd. All Rights Reserved. Code Code Code Code Englis h Englis h Englis h Englis h Chinese Chinese Chinese Chinese…

100%1 / 237
Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 25 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Because the mount height offset is large.
If all are OK, please continue.
󲡹后,如果没󳋃󳕭󲣌󱮼󱯂
󲨉装高度偏差量󲲜大,元件可能干
Ea00444 DATA CHECK ERROR
Unknown error.
程序󰖕󰒺󳇮󲣄
󲲮是原因不明的󳇮󲣄
Ea00445 BOARD DATA ERROR
Too many mount data.
基板程序󳇮󲣄
󲨉装数据数多于󲚙定数。
Ea00446 BOARD DATA ERROR
Too many dot-dispense data.
基板程序󳇮󲣄
正式点胶数据数多于󲚙定数。
Ea00447 BOARD DATA ERROR
Too many pre-dispense data.
基板程序󳇮󲣄
󳕙点胶数据数多于󲚙定数。
Ea00449 BOARD DATA ERROR
The nozzle selected in component info. is not
available for stamping action.
Select appropriate one.
Component data Name
基板程序󳇮󲣄
在元件信息中指定使用的吸嘴,
不能󲲰󳅝浸胶作。
󲣌󲳞适用󳅝浸胶的吸嘴。
元件数据 名称
Ea00452 DATA CHECK ERROR
Current Board data has some data error.
Please read same Board data, and correct wrong data.
程序󰖕󰒺󳇮󲣄
当前󲣐入的基板程序,没有󲲰行程序󰖕󰒺
󲣌重新󲣐入基板程序,修改程序󳇮󲣄
Ea00453 SPECIAL DUMP BACK WARNING
The function "Sp. Dump Back" cannot be used for
Ext. Tray Changer like YTF80W.
Please check "Dump Way" in Component Information.
特殊返󲲭󳇮󲣄
YTF80W 等外部托󱎭󰀷器不能使用[特殊返󲲭理]的弃方法。
󲣌更改元件信息中弃方法的󲢓置。
Ea00454 BOARD DATA ERROR
CO-PLANARITY CHECK is available only when the datum
angle is 0 degree.
Mount data
Component data Name
基板程序󳇮󲣄
形状基准角度在 0 度以外的状下,
不能施引脚󱲭󰖕出。
󲨉装数据
元件数据 名称
Ea00455 Board DATA ERROR
Fiducial skip function can not be used
with tray changer unless it is accompanied
with the all fiducial check function.
基板程序󳇮󲣄
只要基准󰓜󲢅󲲜功能不与全基准󰓜󲢅功能并用,
就不能同󰋋使用托󱎭󰀷器。
Ea00456 BOARD DATA ERROR
At the following head,
the vision type of the dispense nozzle is not defined.
Please set the type.
Head Number No.
基板程序󳇮󲣄
没有󲢓置下列点胶󱓖的点胶嘴的校正󱥐型。
󲣌󲢓置校正󱥐型。
点胶󱓖
Ea00457 BOARD DATA ERROR
At the following head,
the vision type of the dispense nozzle is illegal.
The dispense vision data for the type does not exist.
Please change to the correct type.
Head Number No.
基板程序󳇮󲣄
下列点胶󱓖的点胶嘴的校正󱥐型不正确。
󲢓置的校正󱥐型用的点胶校正数据不存在。
󲣌更改正确的校正󱥐型。
点胶󱓖
Ea00458 TRAY PRECEDE ERROR
In case of component supply from ATS,
if the Dump way set to [Sp.Dump Back],
the Tray Precede function cannot be used.
Please set Tray Precede to [Not Use].
󱎭󳇮󲣄
ATS 元件的弃方法󲢓特殊返󲲭󰋋
不能使用托󱎭先功能。
󲣌把托󱎭󲢓[不行]。
Ea00459 CONFIRMATION OF BLOW MODE
Blow Mode is not set to "Normal".
This could have a negative influence on production.
Please confirm the Blow mode setting.
󲨉󰋋的排气方式确󲡹
[机器󲢓置]1 画面中󲨉󰋋的排气方式不是"普通"。
可能无法在最佳条件下󲲰行生
Ea00460 Multi-Macs Data Error
Multi-Macs data in Machine Data is not correct.
This condition is not good for mounting accuracy.
Please adjust Multi-Macs data in Adjust Utility.
Multi-MACS 数据󳇮󲣄
[机器󲢓置]画面所󲢓置的 Multi-MACS 的校正基准异常。
󱮼󱯂运行,不能正常生
󲣌在[机器󲢓置]画面重新󲣘 Multi-MACS 校正基准
Ea00461 PLEASE CHECK FOR BOARD SIZE HEIGHT
Board Size Height is "0".
If OK, please continue.
注意: 基板厚度数据异常
在基板程序中所󲢓置的基板厚度的数"0"。
󲡹后,如没有󳋃󳕭󲣌󱮼󱯂运行。
Ea00462 BOARD DATA Pre-Dispensing Pos. Warning!
Pre-Dispensing position is outside the Pcb or Dot-Station.
If you start production in this condition,
a head unit may be broken. Please check Board data again.
Pre-Dispense data
基板程序 󳕙点胶位置 警告
󳕙点胶坐󰓜在基板或打点站上的范外。
󱮼󱯂󲲰行,点胶可能与送装置等生干,造成破󰀴
󲣌重新确󲡹数据。
󳕙点胶数据
Ea00463 BOARD DATA Pre-Dispensing Pos. Warning!
Pre-Dispensing position added Y+20mm for checking is
outside the Dot-Station.
If you start production in this condition,
a head unit may be broken. Please check Board data again.
基板程序 󳕙点胶位置 警告
校正量确󲡹作用的󳕙点胶坐󰓜在打点站上的范外。
󱮼󱯂󲲰行,点胶送装置等可能生干,造成破󰀴
󲣌重新确󲡹数据。
󳕙点胶数据
Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 26 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Pre-Dispense data
Ea00464 BOARD DATA ERROR
In Pre-dispense data,
"Feedback" and "Exec." are inputted at the same line.
"Feedback" should be inputted with "Check" or "Skip".
Pre-Dispense data
基板程序󳇮󲣄
󳕙点胶数据中,同󰋋指定了[校正]和[行]。
如指定[校正]󰋋󲣌指定[󰖕󰒺]或[跳󲲜]。
󳕙点胶数据
Ea00465 STATIC COMPONENT WARNING
Static Components are not supported on VGOS,
default parts data will be used instead.
This parts data may not be the same as
the intended Static Components definition.
Please check the components data is correct.
Comp number No.
Comp Name
注意: 固定元件使用警告
元件信息中存在使用固定元件的元件。
Xg 系列中,因不支持固定元件,
所以󲱁󰀷󲡹数据。
󲣌󲡹下列元件信息。
元件号󱓖
元件名称
Ea00466 BOARD DATA ERROR
Illegal component shape data.
Body Size or Body Height or Search Area is 0.
Mount data
Component data Name
基板程序󳇮󲣄
元件形状信息的外形尺寸 X、Y、元件高度、
󰖕出范"0""。
󲨉装数据
元件数据 名称
Ea00467 BOARD DATA ERROR
Too many Height Correction Data.
基板程序󳇮󲣄
内存的分配已失󲧺
高度校正数据的数量󲲜多。
Ea00471 TIMEOUT ERROR
Cannot receive a signal from SEQUENCE UNIT;
( Waffle Tray Changer, Special Feeder etc... )
UNIT No.
󱮮装置超󰋋󳇮󲣄
󱮮装置(蜂󱝲状托󱎭󰀷器、其他供󱮮装置)没有答信号。
要求更󰀷元件(托󱎭)的指令,没有答信号。
可能是由于没有供󱮮元件(托󱎭)而使得无法󲲰 READY
󱂅象造成。
装置号󱓖
Ea00472 SEQUENCE UNIT ERROR
An error signal was received from SEQUENCE UNIT,
( Waffle Tray Changer, Special Feeder etc... )
Please check it, and solve the problem.
UNIT No.
󱮮装置󳇮󲣄
从供󱮮装置(蜂󱝲状托󱎭󰀷器、其他供󱮮装置),
󲱨入了󳇮󲣄信号。
󲣌󲡹󱮮装置是否有󳋃󳕭
装置号󱓖
Ea00473 BOARD DATA ERROR
In Mount/Sequence Info., there is an illegal mode parameter.
Please, check the following data.
Mount data
基板程序󳇮󲣄
在[󲨉装信息][作流程信息]中指定了异常"方式",󲣌󲡹
󲨉装数据
Ea00474 BOARD DATA ERROR
There is an invalid mark data referenced from Mount data.
Please, check the following items:
- The mark data does not exist.
- The mark data number is illegal value.
- Mark Type is not Check1 or Check2.
- Src.Offset and Diff.Pos are active at the same time.
Mount data
Mark data Name
基板程序󳇮󲣄
在[󲨉装信息]中指定的󰓜󲢅数据异常。
可能是由以下原因所致,󲣌󲡹
·使用了不存在的󰓜󲢅数据。
·指定的󰓜󲢅󱓖󲚙外。
·󰓜󲢅数据的󰓜󲢅功能在[󰖕󰒺 1]和[󰖕󰒺 2]之外。
·󰋋使用了󰓜󲢅数据的[󰖕出偏移量]和[位置公差]。
󲨉装数据
󰓜󲢅数据 名称
Ea00475 BOARD DATA ERROR
There is an invalid Dot-dispense data referenced
from Mount-Info.
Please, check the following item:
- is there Dot-dispense data referenced from Mount data?
Mount data
基板程序󳇮󲣄
在[󲨉装信息]中指定的正式点胶数据异常。
以下可能是造成异常的原因,󲣌󲡹
·使用了不存在的正式点胶数据。
·指定的正式点胶号󱓖󲚙外。
󲨉装数据
Ea00476 BOARD DATA ERROR
[StationNo] of component info is wrong.
Component data Name
基板程序󳇮󲣄
在[元件数据]的[浸胶]画面中指定的装置号󱓖异常。
以下可能是造成异常的原因,󲣌󲡹
·󲢺󲨉装工作台中指定了不存在的装置号󱓖
元件数据 名称
Ea00477 BOARD DATA ERROR
Mark position in the mount/sequence data is outside moving area.
Mount data
Axes
基板程序󳇮󲣄
在[󲨉装信息]或[作流程信息]中所指定的󰓜󲢅󲢛/󰖕󰒺位置
作范外。
󲨉装数据
󲱉名称
Ea00478 BOARD DATA ERROR
There is an invalid head number in Mount-Info or Sequence-Info,
or this head can not do dot-dispense.
Mount data
基板程序󳇮󲣄
在[󲨉装信息]或[作流程信息]中所指定的 Head 异常。
可能由下列原因造成,󲣌󲡹
·指定的 Head 󱓖󲚙外。
Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 27 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Head number ·指定的 Head 不能󲲰行正式点胶。
󲨉装数据
Head 号󱓖
Ea00479 BOARD DATA ERROR
Dot-dispense position in the mount data or sequence data
is outside moving area.
Mount data
Axes
基板程序󳇮󲣄
在[󲨉装信息]或[作流程信息]中所指定的正式点胶位置
作范外。
󲨉装数据
󲱉名称
Ea00480 DISPENSE ERROR
Dispense fluid sensor detects the fluid is used up.
Dispensing can not continue in this condition,
please exchange the fluid.
Head number
胶液余量󳇮󲣄
胶液余量的感器已感出胶液量不足。
不能󱮼󱯂运行,󲣌󰀷胶液。
点胶󱓖
Ea00481 BOARD DATA ERROR
A head can not move on the dipping station referenced
by Component Info.
Please, check the following item;
[StationNo] of Component Info.
[Dipping Station ? Origin] or [Size] of MCH_DATA - Position.
Component data Name
基板程序󳇮󲣄
Head 不能到达浸胶站的有效范内。
以下可能是造成异常的原因,󲣌󲡹
·元件信息中的装置号󱓖󲢓置异常
·浸胶站的󲢓置(原点、尺寸)异常
元件数据 名称
Ea00482 BOARD DATA ERROR
A head can not move on the "DIPPING STATION" referenced
by [DIP] of [Component Info].
Please, check the following item;
The parameters in [DIPPING STATION] of Board data.
Component data Name
基板程序󳇮󲣄
Head 不能到达浸胶站的有效范内。
以下可能是造成异常的原因,󲣌󲡹
·基板程序中浸胶站的󲢓置异常
元件数据 名称
Ea00483 PREDIPPING STATION REPORT
Pre-Dipping number met a limit.
Pre-Dipping number is cleared.
Pre-Dipping wipe out a station.
浸胶󲢪打点站
浸胶󲢪打点站上的浸胶󲢪打点数量已达到极限。
清除浸胶󲢪打点数。
󲣌擦拭浸胶󲢪打点站。
Ea00484 TIMEOUT ERROR
Cannot receive a signal of dipping station.
󰋋󳇮󲣄
浸胶站没有答信号。
Ea00487 BOARD DATA ERROR
This machine has no dipping station,
but the Board data requires it.
Please check the parameter of MACHINE DATA.
基板程序󳇮󲣄
󲍒然在[元件信息]中指定了[浸胶作],
但没有装浸胶站。
以下可能是造成异常的原因,󲣌󲡹
·[󲳞󳕎构成]-[浸胶站]的󲢓[没有]。
元件数据 名称
Ea00488 WARNING: DIPPING STATION
The dipping station has been stopped over specified time.
Please check the condition of it, and
if need turn it by manual operation.
浸胶站 警告
浸胶站已停止了一定󰋋󳋉以上。
󲣌󲡹胶液状,如果有必要,
󲣌用手方式󲲰行浸胶站的󲢪运行。
Ea00489 WARNING: DIPPING STATION
There is a head stopped in dipping on dipping station.
The component will be dumped.
浸胶站 警告
有在浸胶站的浸胶作中中断作 Head。
󲢺 Head 吸附的元件将不会󲨉装。
Ea00490 BOARD DATA ERROR
Bottom side clearance is too big.
Axes
This value should satisfy the following equation.
PT + BSC <= IP - IM
PT : Board thickness
BSC : Bottom side clearance
IP : Init. pos of PU axis(Machine data)
IM : Init. move of PU axis(Machine data)
基板程序󳇮󲣄
背面最大元件的高度󲲜高。
󲱉名称
󲢺󳕐󰮶足下列算式。
PT + BSC <= IP - IM
PT : 基板厚度
BSC : 背面最大元件高度
IP : PU 󲱉初始位置([机器󲢓置]-[机器数据])
IM : PU 󲱉初始移([机器󲢓置]-[机器数据])
Ea00492 MARK DETECTION ERROR
Failed to detect marks.
[upper row:Local Bad Number. lower row:Recognize Result.]
󰓜󲢅󲢛󳇮󲣄
未能󲢛下列󲨉装号󱓖所指定的󰓜󲢅
󰒺明原因解决后,󲣌重新行或作上󰓜󲢅
[上行:局部坏板󰓜󲢅󱓖,下行:辨󱮨果]
Ea00493 MARK DETECTION ERROR
Failed to detect marks. Please check and restart.
[upper row:Local Bad Number. lower row:Recognize Result.]
󰓜󲢅󲢛󳇮󲣄
未能󲢛下列作流程数据所指定的󰓜󲢅
󰒺明原因解决后,󲣌重新行。
[上行: 局部坏板󰓜󲢅󱓖,下行:辨󱮨果]