YAMAHA 报警资料.pdf - 第221页
Comparison Table ( English - Chinese ) VGOS V2.46STD R1.000 221 / 237 Copyright (C) 2009 Y amaha Motor Co.,Ltd. All Rights Reserved. Code Code Code Code Englis h Englis h Englis h Englis h Chinese Chinese Chinese Chinese…

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 220 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Although production of a stock-in-hand kind cannot be continued
when auto plan mode is changed, do you want to chage auto plan mode?
更改切模式后,不能当前品的生。
需要更改切模式?
Ea25636 THERE IS NO BOARD ID INFOMATION.
Board ID information doesn't exist in sub stopper position.
Automatic plan operation can't be continued.
Remove the board of sub stopper position.
无基板 ID 信息
待机位置不存在基板 ID 信息。
在此状下无法用自切生品功能行运行。
取出待机位置的基板。
Ea25637 THERE IS NO BOARD ID INFOMATION.
Board ID information doesn't exist in upper buffer conveyor position.
Automatic plan operation can't be continued.
Remove the board of upper buffer conveyor position.
无基板 ID 信息
上冲送位置上不存在基板 ID 信息。
在此状下无法使用自切生品功能行运行。
取出上冲送装置上的基板。
Ea25638 THERE IS NO BOARD ID INFOMATION.
Board ID information doesn't exist in main stopper position.
Automatic plan operation can't be continued.
Remove the board of main stopper position.
无基板 ID 信息
印刷位置不存在基板 ID 信息。
在此状下无法使用自切生品功能行运行。
取出印刷位置上的基板。
Ea25639 Auto plan start error
The error occurred during the automatic plan change.
The current board data differs from the program name
contrasted from production kind information.
Production of as it is present is uncontinuable.
When you resume production, please cope with it as follows.
1.Automatic plan use mode is changed into "No Use."
2.Board data is reread from a Setup screen.
3.Automatic plan use mode is changed into "Use."
4.Automatic operation is resumed and
production kind information is reread.
自切生品功能始
在切自切生品功能中生了。
当前入的基板程序与生品信息所的程序名称不一致。
无法当前的生。
如重新始生,按照如下行。
1.将自切生品功能的使用模式更改[不使用]。
2.在生画面重新入基板程序。
3.将自切生品功能的使用模式更改[使用]。
4.重新始自运行,重新入生品信息。
Ea25640 Auto plan warning
The error occurred during automatic plan operation.
Please cope with it as follows and
check the contents of an error displayed.
-It stands by until all the Board in a machine are conveyed.
-Auto running is stopped.
自切生品警告
使用自切生品功能行运行的程中生了。
按照如下方法之一,确示的内容。
·使机器置于待机状,直至机器内的基板全部出止。
·停止自运行。
Ea25641 NO BOARD DATA
Although automatic reading of a dummy board was performed,
the specified Board data does not exist.
BOARD DATA %s
无基板程序
行了虚基板的自入,但指定的基板程序
没有登在机器中。
基板程序 %s
Ea25642 Auto Plan start error
In the state where there is no production kind information,
Auto plan was started.
Auto plan cannot be started with this.
Since production kind information is reread, please start production.
自切生品功能始
在没有生品信息的状下,始了自运行。
在此状下无法始自切生品功能。
重新入生品信息后,再始生。
Ea25643 KANBAN ID READOUT ERROR
KANBAN ID cannot be read.
Cause
It is an auto plan "Not Use."
Please change to an auto plan "Use".
条板 ID 取
不能取条板 ID。
原因
自切生品功能于[不使用]状。
将自切生品功能切[使用]。
Ea25644 KANBAN ID READOUT ERROR
KANBAN ID cannot be read.
Cause
Next ASSY information has already been registered.
Please cancel registered information when you want to
register ASSY information again.
Please reset it when you want to cancel.
条板 ID 取
不能取条板 ID。
原因
已登了下个品信息。
重新登品信息,
将已登品信息取消。
若要取消,先初始化。
Ea25645 KANBAN ID READOUT ERROR
KANBAN ID cannot be read.
Cause
The error occurred during automatic plan operation.
Please cope with it as follows and
check the contents of an error displayed.
-It stands by until all the Board in a machine are conveyed.
-Automatic operation is stopped.
条板 ID 取
不能取条板 ID。
原因
使用自切生品行运行的程中生了。
按照下列方法之一,确所示的内容。
·置于待机状,直至机器内的基板全部送完止。
·停止自运行。
Ea25646 KANBAN ID READOUT ERROR
KANBAN ID cannot be read.
Cause
KANBAN ID cannot be read at a present operator level.
Please operate it by the operator to whom the readout
of KANBAN ID is permitted.
条板 ID 取
不能取条板 ID。
原因
当前的操作不能取条板 ID。
由允取条板 ID 的操作者行操作。
Ea25647 KANBAN ID READOUT ERROR
KANBAN ID cannot be read.
Cause
A Board or Board ID information exists in equipment.
Please reset it after removing all Board and Board ID information
in equipment.
条板 ID 取
不能取条板 ID。
原因
内存在基板、或 ID 信息。
将内的基板、或 ID 信息全部除。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 221 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Ea25648 KANBAN ID READOUT ERROR
KANBAN ID cannot be read.
Cause
Emergency Stop Function Is Active.
Check for safe conditions and
press the READY button to
re-enable the machine.
条板 ID 取
不能取条板 ID。
原因
急停机正在作用。
确安全,并按急停机解除按。
Ea25650 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
The Board program name and current Board program name of a take over File differ
from each other.
Please, check the following data.
Board name in take over file %s
自切生品功能 坏板信息送
移交文件的基板程序名和当前的基板名不一致。
确移交文件。
移交文件的基板程序名:%s
Ea25651 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
The number of BLOCK BADMARK of a take over file is not in agreement with the
contents registered into the board.
Please, check the following data.
BLOCK BADMARK data in take over file.
自切生品功能 坏板信息送
移交文件的拼坏板数和基板登内容不一致。
确移交文件。
Ea25652 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
The number of LOCAL BADMARK of a take over file is not in agreement with the
contents registered into the board.
Please, check the following data.
LOCAL BADMARK data in take over file.
自切生品功能 坏板信息送
移交文件的局部坏板数和基板登内容不一致。
确移交文件。
Ea25653 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
No BADMARK transmission data in take over file.
Please, check the following data.
BADMARK data in take over file.
自切生品功能 坏板信息送
移交文件中不存在坏板送信息。
确移交文件。
Ea25654 The Board has been lost.
The Board on the lower buffer conveyer has been lost at the following position.
[Check position]
Please return the Board to former position according to the
position of ID information.
Please delete ID information when you remove the Board as it is.
ID information on the conveyer can be confirmed by the ID monitor.
失了基板
在下位机冲送装置的下列位置上,失了基板。
[位置]
根据 ID 信息的位置,将基板放回原来的位置。
如立即取出基板,除 ID 信息。
送装置上的 ID 信息,可在 ID 控屏行确。
Ea25655 Illegal Board was detected.
An illegal Board was detected on the lower buffer conveyer at the following position.
[Check position]
Please remove an illegal Board without ID information.
ID information on the conveyer can be confirmed by the ID monitor.
出的基板不正确
在下位机冲送装置的下列位置上,出了基板。
[位置]
取出没有 ID 信息的基板。
送装置上的 ID 信息,可在 ID 控屏行确。
Ea25656 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
Failed to get Board BADMARK data.
自切生品功能 坏板信息送
基板坏板信息的取失了。
Ea25657 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
Failed to get BLOCK BADMARK data.
自切生品功能 坏板信息送
拼坏板信息的取失了。
Ea25658 AUTO PLAN BADMARK INFORMATION TRANSMISSION ERROR
Failed to get LOCAL BADMARK data.
自切生品功能 坏板信息送
局部坏板信息的取失了。
Ea25659 Put In Board
It puts in the following Board removed in the past.
Lot Num:%d
Serial Num:%s
Board Count:%d
Mounting Status:%s
Removed Time:%s
Removed Equipment:%s
Please check a Board and put in %s.
基板的中途投入
中途投入以前曾取出的下列基板。
批号 :%d
序列号 :%s
定生枚数:%d
装状 :%s
取出 :%s
取出 :%s
确基板并投入到%s。
Ea25660 Removed Board Id Delete
Do you want to delete Removed Board Id of the line chosen now?
除取出基板 ID
除当前所行的取出基板 ID ?
Ea25661 Put In Board Error
Removed Board Id chosen now does not already exist
by the deletion from other equipment, or automatic deletion.
中途投入
当前的取出基板 ID 已被其他或自除功能
所除,已不存在了。
Ea25662 Kind Mismatch of The Board Id To Put In
The Board to put in was detected as production kind information differed.
Assy:%s
Surface Information:%s
Program Name:%s
Does it plan from this information?
中途投入基板的品不一致
出了与生品信息不一致的中途投入基板。
Assy 号 :%s
生面信息 :%s
生程序名 :%s
用信息行生品切?
Ea25663 Auto Plan Invalid Path Error
The following automatic plan setting path is an invalid path.
Please change into an effective path.
%s
自切生品功能 置路径无效
以下自切生品功能的置路径无效路径。
更改有效的路径。
%s
Ea25664 Program List File Write Failure
The writing of a file went wrong.
Please check the state of a file and edit again.
程序列写入
程序列的写入失了。
确文件的状,并重新行。
Ea25665 Program List UnSaved 程序列文件未保存

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 222 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Program List is edited.
Do you want to save a Program List file?
[YES] It saves file and the dialog closes.
[NO] The dialog closes without save file.
[CANCEL] It doesn't save, and the dialog doesn't close.
程序列已更改。
保存?
[是] 保存并框。
[否] 不保存,框。
[取消] 不保存,返回框。
Ea25666 Program List File Superscription Confirmation
Do you want to overwrite a present content of the edit to the Program List file?
程序列文件覆盖保存确
是否将更改的部分覆盖保存到程序列?
Ea25667 Program List File Maintenance Confirmation
Kind Information on 3000 lines
or more is registered in Program List file.
The performance of the machine might decrease
when 3000 lines or more are registered.
程序列警告
程序列已登了 3000 行以上的品。
登品超 3000 行,机器的性能可能降低。
Ea25668 Program List File Maintenance Confirmation
Same two or more Kind information
as Program List file is registered.
Please edit Program List file.
程序列警告
程序列中登了数个相同的品。
程序列。
Ea25669 Now reading the File... 正在入文件...
Ea25670 Now writing the File... 正在写入文件...
Ea25671 Program List UnSaved
The Program List file doesn't exist the reference folder.
Do you want to create the Program List file served a current content?
[YES] It saves file and the dialog closes.
[NO] The dialog closes without save file.
[CANCEL] It doesn't save, and the dialog doesn't close.
程序列文件未保存
程序列文件不在参照目的地。
建保存当前内容的文件?
[是] 保存并框。
[否] 不保存并框。
[取消] 不保存并返回框。
Ea25672 Board ID Information Recovery
Board ID information on production exists.
The restoration of board ID information is based on information on production.
%s
基板 ID 信息原确
存在生途中的基板 ID 信息。
以生途中信息基,原基板 ID 信息。
%s
Ea25673 Board ID Reading Result Is Not Input
Please input "Board ID Reading Result".
基板 ID 取果 未入
入基板 ID 取果。
Ea25700 Change traceability log folder
Failed to save a traceability log.
Traceability log folder is changed
to spare path.
更改跟踪日志保存位置
因跟踪日志的保存失了,
所以保存位置已切文件。
Ea25701 Change traceability log folder
Disk free space of traceability log
folder is low.
Traceability log folder is changed
to spare path.
更改跟踪日志保存位置
保存位置的磁空不足。
已切文件了。
Ea25702 Recover traceability log folder
Traceability log folder is recovered.
原跟踪日志保存位置
保存位置已原了。
Ea25703 Disk free space is low
Disk free space of traceability log
folder is low.
Check traceability log folder.
跟踪日志保存位置磁空不足。
保存位置的磁空不足。
确保保存位置的磁空。
Ea25704 Can't save traceability log
Can't save traceability log.
So it can not execute auto running.
Start auto-running again after check traceability log folder.
不能保存跟踪日志
因无法保存跟踪日志,
所以不能行自运行。
确跟踪日志的保存位置,
再重新始运行。
Ea25830 PositionFreeSetup
Are the parts freely arranged?
自由切作确
是否行因剩余数而停止的元件的自由切?
Ea25831 PositionFreeSetup Error
Board data is changed.
Please save the board data to execute the setup check
to the changed board data.
自由切
基板程序已更改。
保存基板程序后,重新入。
Ea25832 PositionFreeSetup Error
The adsorption operation of parts cannot be done at the installed
feeder set position.
Please install those parts in another position.
自由切
已安装的送料器安装位置上无法行元件的吸附作。
安装到其他位置上。
Ea25833 PositionFreeSetup Error
Parts demanded by the substrate data are not installed in the machine.
Please confirm parts installed in the feeder.
自由切
基板程序所要求的元件没有安装在机器上。
确安装在送料器上的元件。
Ea25834 PositionFreeSetup Error
The error message, the alert message or the dialog box is displayed.
It was not possible to begin to optimize automatically,
and to drive automatically.
Begin to shut clearness or the dialog of the message, and to drive.
自由切
因提示、警告提示、或框于示状,
所以未能始自最化、自运行。
清除提示或框后,再始运行。
Ea25835 PositionFreeSetup 自由切作确