YAMAHA 报警资料.pdf - 第66页
Comparison Table ( English - Chinese ) VGOS V2.46STD R1.000 66 / 237 Copyright (C) 2009 Y amaha Motor Co., Ltd. All Rights Reserved. Code Code Code Code Englis h Englis h Englis h Englis h Chinese Chinese Chinese Chinese…

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 65 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Failed to delete SchedleTaskLastDate.ini "SchedleTaskLastDate.ini"的除失了。
Ea02648 FILE WRITE ERROR
Failed to write SchedleTaskLastDate.ini
度程序任最行文件 写入
"SchedleTaskLastDate.ini"的写入失了。
Ea02649 FILE READ ERROR
Failed to read SchedleTaskLastDate.ini
度程序任最行文件 入
"SchedleTaskLastDate.ini"的入失了。
Ea02650 CONVEYOR MOTOR ALARM
Control board of conveyor motor detected error.
Motor No.
出送达异常
已出送达控制基板异常。
达号
Ea02651 CONVEYOR TIMEOUT ERROR
Conveyor table axis can not move.
送装置送超
不能移送工作台的。
Ea02652 INTERLOCK ERROR
You can't move X ,Y ,R or W axis,
because Z axis is not in safe position.
Please check Z axis position.
因 Head 的高度在危的位置,
所以不能移 X、Y、R、W 。
将 Head 移到安全的高度。
Ea02653 INTERLOCK ERROR
Z axis is not in a safe position.
Please check Z axis position.
Head 的高度在危的位置。
将 Head 移到安全的高度。
Ea02654 INTERLOCK ERROR
Moving conveyor cannot move.
The cause is which the following:
1. There is a Board on the edge of the moving conveyor.
2. Sensor reacts to the Head.
Please remove the problem.
可送无法移。
<原因>:
1. 可送中部上有基板。
2. Head 感器有反。
排除原因。
Ea02655 PS-FEEDER TIMEOUT ERROR
Timeout error occurred, because PS-Feeder was busy.
Please check feeder.
Feeder No.
PS 送料器超
因 PS 送料器在忙碌状,而生了超。
送料器。
送料器号 号
Ea02656 DATA CHECK ERROR
Some components can not be recognized,
because there is no camera with side light.
Component No.
程序
然元件信息中存在使用面照明的元件,
但机器没有面照明功能,所以不能使用。
元件数据号 号
Ea02657 DATA CHECK ERROR
Conveyor Spec : Manual Return
Conveyor Direction : L->R
It must be such setting for Cell Production.
Please reconfirm machine setting.
程序
送送方法:手 U 形
送送方向:左→右
在元生中需置成上所示。
确机器置的置内容。
Ea02658 BOARD DATA ERROR
No nozzle is available.
基板程序
没有可以使用的 Nozzle。
Ea02659 BOARD DATA ERROR
A nozzle interferes in the conveyer when mount is carried out
in the specified mount coordinate.
For this machine, in the Y-axis direction, the range of 5mm
from the edge of the Board can't carry out mounting.
Please modify a mount coordinate.
Mount Data
Block Data
基板程序
如在指定装坐上行装,
送和吸嘴将相互碰撞。
此机器, Y 方向,从基板的
端起 5mm 的范内不能装。
修改装坐。
装数据 号
拼数据 号
Ea02700 FORCE CONTROL UNIT ERROR
Because it has not finished initializing the force control
unit, the machine cannot start running.
Please check the unit, and try 'Origin' again.
荷控制装置
荷控制装置的初始化未完成。
状下机器是不能运行的。
确装置,重新行返回原点。
Ea02701 NOZZLE STATION MACS ERROR
Failed to read MACS for Nozzle Station.
Please check mark database number in machine data,
and mark data in mark database.
Database No.
吸嘴交站 MACS
吸嘴交站 MACS 的入失了。
机器置的数据号确正确?
确在数据中登了有效的数据?
数据号 号
Ea02702 NOZZLE STATION MACS ERROR
Failed to execute Nozzle Station MACS.
Please check the machine data,
and mark data in mark database.
吸嘴交站 MACS
吸嘴交站 MACS 的作中失了。
吸嘴交站 MACS 相的机器置、
正在参照的数据是否有?
Ea02703 NOZZLE STATION MACS ERROR
Failed to detect Nozzle Station MACS.
Does the MACS look dirty?
or check mark data in mark database.
吸嘴交站 MACS
吸嘴交站 MACS 的失了。
吸嘴交站 MACS 是否有垢?
正在参考的数据是否正确?
Ea02704 NOZZLE STATION MACS ERROR
No mark data for Nozzle Station MACS has read.
Please read any Board data again.
吸嘴交站 MACS
没有吸嘴交站 MACS 用的数据。
在生画面中重新入基板程序。
Ea02705 NOZZLE HEIGHT INCOMPLETE
The machine cannot start auto-running.
吸嘴高度量未完成
因吸嘴高度的量未完成,
所以不能始自运行。
Ea02706 NOZZLE STATION MACS ERROR
Nozzle Station MACS position from the original
吸嘴交站 MACS
吸嘴交站 MACS 的校正异常。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 66 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
is over the limitation.
Does the MACS look dirty?
Pos X (mm)
Pos Y (mm)
有的可能,。
校正 X (mm)
校正 Y (mm)
Ea02707 VERIFICATION UN-COMPLETED
There is a part that is not verified during setup.
Start auto-running again after you complete
the setup verification.
校未束
存在未校的元件。
确校后,再次启运行。
Ea02708 START RUNNING WITH THE UN-SAVED DATA
This board data is being edited.
To start auto running, please save the PCB data.
This message is shown in "Setup Check" and "Traceability" function.
正准用未保存的基板程序行自运行
基板程序正在。
如要始自运行,保存基板程序。
本信息在使用送料器安装位置或跟踪功能才示。
Ea02709 FAILED TO SAVE TRACEABILITY LOG
Failed to save a traceability log specifiedpath and
also to the spare path.
This message is shown in IT option "Traceability" function.
跟踪日志保存失
跟踪日志的保存失了。
本信息在 IT 跟踪功能使用才示。
Ea02710 INTERLOCK ERROR
You can't change conveyor width,
because push-up unit is up.
因装置正在上升,所以不能改基板幅。
Ea02711 OPERATION ERROR
Machine can not start auto-running,
because head is down.
Please check head unit.
启始危
因 Head 下降状,所以不能始运行。
确 Head 的状。
Ea02712 OPERATION ERROR
Machine can not start auto-running.
The cause is which the following:
1. There is a Board on the edge of the moving conveyor.
(between entrance and upper-stage)
Please move the Board to safety position.
2. It has the possibility that the sensor detects a head.
Please move the head to the position
where the sensor does not detect it.
启始危
不能始运行。
<原因>
1. 入口、上流基板台的送中部上有基板。
将基板移到安全的位置上。
2. Head 可能感器有反。
将 Head 移到不感感器的位置上。
Ea02713 OPERATION ERROR
Machine can not start auto-running.
The cause is which the following:
1. There is a Board on the edge of the moving conveyor.
(between upper-stage and lower-stage)
Please move the Board to safety position.
2. It has the possibility that the sensor detects a head.
Please move a head to the position
where the sensor does not detect it.
启始危
不能始运行。
<原因>
1. 上流、下流基板台的送中部上有基板。
将基板移到安全的位置上。
2. Head 可能感器有反。
将 Head 移到不感感器的位置上。
Ea02714 OPERATION ERROR
Machine can not start auto-running.
The cause is which the following:
1. There is a Board on the edge of the moving conveyor.
(between lower-stage and exit)
Please move the Board to safety position.
2. It has the possibility that the sensor detects a head.
Please move a head to the position
where the sensor does not detect it.
启始危
不能始运行。
<原因>
1. 下流基板台、出口的送中部上有基板。
将基板移到安全的位置上。
2. 装可能感器有反。
将基板装移到不感感器的位置上。
Ea02715 HALFWAY CONTINUE ERROR
Machine can not find Board on mount stage.
This machine needs existing Board on mount stage when
it execute Halfway continue.
Please set Board on mount stage correctly and start
auto run.
中途装装位置
行中途装的基板,不在装位置上。
机器行中途装,基板必在装位置上。
将象基板正确安置在装位置上,然后重新启
运行。
Ea02716 Failed to calibrate Spring force.
Failed to get the parameters for Calibration.
Check the force control specification.
簧荷校正
簧荷的校正已失。
未取得荷校正所必需的参数。
修改荷控制格信息。
Ea02717 CARIBTATION STATION ERROR
detected breakdown from the load cell on the calibration station.
The cause is which the following:
1. calibration station isn't attached to the machine.
2. calibration station is broken.
荷校正站
校正站上的元件的入异常。
可能由以下原因造成。
1. 校正站未接。
2. 校正站坏等。
Ea02718 FORCE VALUE ERROR
The measurement result of the load value exceeded the tolerance.
The cause is which the following:
1. Nozzle is broken.
2. Head wasn't be able to reach the load cell.
3. Position XYZ of the calibration station are wrong.
Please check the state of nozzle or
荷
荷果已超出容范。
可能由以下原因造成。
1. 吸嘴坏。
2. 行了,但未得到吸嘴高度。
3. 校正站坐(XYZ)。
修改吸嘴状或者荷控制格信息。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 67 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
force control specification.
Table No.
Head No.
工作台号
Head 号
Ea02719 NOZZLE HEIGHT DISPLACEMENT ERROR
Nozzle height measurement failed.
Before starting the measurement, a
Touch-Sensor signal was received.
Please check:
- the Touch-Sensor connection
- if the Touch-Sensor is broken etc...
吸嘴高度
吸嘴高度失了。
·吸嘴高度之前,触摸感器已做出感。
—〉触摸感器没有接或已坏等。
Ea02720 NOZZLE HEIGHT DISPLACEMENT ERROR
Nozzle height measurement failed.
The result that as measured is very different
from the standard value.
Q) Check the XYZ position of Touch-Sensor.
Check the head offset value.
Check specified nozzle length
Check if the nozzle is plugged.
Error Distance mm
吸嘴高度
吸嘴高度失了。
·果与目相差太大。
—〉触摸感器坐 Z
Head 偏移量
吸嘴格中吸嘴度
吸嘴前端堵塞
量差 mm
Ea02721 NOZZLE HEIGHT DISPLACEMENT ERROR
Nozzle height measurement failed.
The signal from the Touch-Sensor is not good.
Q) Is Touch-Sensor connected ?
Is Touch-Sensor active ? etc...
Machine couldn't get result by moving head.
Q) Check the XYZ position of Touch-Sensor.
Check the head offset value.
Check the nozzle length of nozzle spec.
吸嘴高度
吸嘴高度失了。
·触摸感器的入异常。
—〉触摸感器没有接或已坏等。
·行了,但未到吸嘴高度。
—〉触摸感器坐 Z
Head 偏移量
吸嘴格的吸嘴
Ea02722 DON'T YOU NEED HALFWAY CONTINUE?
A board that is not finished to mount exist on the mounting position.
If you continue auto running, a halfway board may be transferred.
Please confirm the board condition and execute halfway continue command
if necessary.
运行始确
装位置上存在没有正常完成装的基板。
如照旧自运行,没有装的基板可能会至下流。
确装位置上的基板状,如没有完成装的状,
用中途始运行的指令完成装。
Ea02723 PCB DATA ERROR
Ext.TC or AutoTC is not available, because
both of them are not exist on this machine.
Component Name
基板程序
因未装外部托交器或自托交器
所以不能使用。
元件数据 名称
Ea02724 LASER HEIGHT DISPLACEMENT ERROR
Failed to write parameters to the laser amplifier.
During startup the parameters are written
automatically.
Please reboot the machine.
激光高度
向激光放大器的参数写入已失。
机器启,将自行参数的写入。
重新启源。
Ea02725 NOZZLE STATION UP ERROR
Failed to move up for nozzle changing.
The cause is which the following:
1.The Valve to move nozzle station is broken.
2.The sensor of upper side is OFF.
吸嘴站上升
吸嘴站的上升作失了。
可能由以下原因造成的。
·吸嘴站升降作不良。
·吸嘴站上升端无反。
Ea02726 NOZZLE STATION DOWN ERROR
Failed to move down for nozzle changing.
The cause is which the following:
1.The Valve to move nozzle station is broken.
2.The sensor of lower side is OFF
吸嘴站下降
吸嘴站下降作失了。
可能由以下原因造成的。
·吸嘴站升降作不良。
·吸嘴站下降端探无反。
Ea02727 FLYING NOZZLE CLUTCH POSITION ERROR
Failed to exchange flying nozzles,
because clutch sensor condition is off.
The cause is which the following:
1.Clutch position of R axis is wrong.
2.Initial position of R axis is wrong.
Head.No
FNC 离合器位置
下列 Head 中的某个离合器感器生感,
所以不能行吸嘴交。
可能由以下原因造成。
1.象 Head 的离合器角度歪斜。
2.R 初始位置的整不良。
Head 号
Ea02728 FLYING NOZZLE EXECHENGE TIMEOUT ERROR
Failed to exchange flying nozzles.
Please check failed head condition.
行式吸嘴交超
不能行行式吸嘴交。
确 Head 的状。
Ea02729 PICK POSITION SOFTLIMIT ERROR
Pick-up position of follows component is outside
moving area.
In case of Tray supplied component, check the pick
吸附位置极限溢出
下列元件的吸附位置在作范外。
在元件信息中确吸附位置。
于托元件,确是否托上的全部元件在吸附范之内。