YAMAHA 报警资料.pdf - 第7页
Comparison Table ( English - Chinese ) VGOS V2.46STD R1.000 7 / 237 Copyright (C) 2009 Y amaha Motor Co.,Ltd. All Rights Reserved. Code Code Code Code Englis h Englis h Englis h Englis h Chinese Chinese Chinese Chinese P…

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 6 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Comment
Feeder set position
Table/Head
送料器安装位置 号
工作台/Head
Ea00047 EDGE DETECTION ERROR(code 71)
Laser detection error: Too many edges detected.
Component may be incorrectly positioned.
Mount data
Component data Name
Comment
Feeder set position
Table/Head
出 (code 71)
不能出元件的。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
工作台/Head
Ea00048 PICK UP ERROR
Failed to pick up the component from the Vacuum Check.
Please check if the feeder or tray is empty.
Mount data
Component data Name
Comment
Feeder set position
Pallet set position
Table/Head
元件吸附
元件吸附出了真空异常。
可能元件用完或送料堵塞。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
料架抽出位置 号
工作台/Head
Ea00049 NOZZLE PLUGGED ERROR
Possible causes :
1. The value of [Low level] of current head is
too small.
2. There is a component under the current nozzle.
3. Current nozzle is plugged.
Please remove cause.
吸嘴堵塞
可能由以下原因造成。
1.当前使用的装[吸附]的数太小。
2.吸嘴上附有元件。
3.所使用的吸嘴确已堵塞。
并解决。
Ea00050 DETECT THE PICK ERROR BY LAM
Detected the component that has been picked up
incorrectly.
Mount data
Component data Name
Comment
Feeder set position
Table/Head
元件立出
通激光出元件吸附异常。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
工作台/Head
Ea00051 MARK DETECTION ERROR
Failed to detect fiducial mark.
出
不能出基准。
Ea00052 MARK AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter
is out of tolerance.
面/周
在指定的面或周的公差范之内,
无法出基准。
Ea00053 MARK DETECTION ERROR
A part of the fiducial mark is located out of
the specified search area or the fiducial
correction angle is too large.
出的基准的一部分越出了搜索区域。
或者,基准的校正角度大。
Ea00054 MARK SHAPE ERROR
Failed to detect a fiducial mark of the
specified shape
形状
不能出指定形状的基准。
Ea00055 MARK AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter
is out of tolerance (Special)
面/周
在指定的面或周的公差范之内,
无法出基准。(特殊形状)
Ea00070 BOARD TRANSFER ERROR
Unexpected board is on the conveyor.
基板送
入送装置的基板超了定数量。
Ea00071 BOARD TRANSFER ERROR
The board detected before transfer is not detected
after transfer. The board should be
on the conveyor.
Set the board to its normal position manually.
基板送
送前出的基板,送后没有被出。
可能送上有基板存在。
太危,将基板放置在正确的位置上。
Ea00072 Machine is unable to start running
because the conveyor width is not ready.
Misalignment of PUSH_UP PINS or board on
conveyor may damage machine.
Ensure safety and change conveyor width
by [Unit] [Width] button, then start again.
送度没有,不能始运行。
因未整的位置或送上有基板,很危,
确安全后,在[装置]的[送度]画面中
送度后,重新启机器。
Ea00073 BOARD TRANSFER ERROR
Board is detected on the edge of the moving
conveyor. Set the board to its normal position
manually.
基板送
在可送中部了基板。
太危,将基板放置在正确的位置。
Ea00074 BOARD FIXING ERROR
Board trans-unit, locate pin or push-up unit
does not respond to command.
基板固定
基板送装置、定位、等没有正常作。
Ea00075 DUMP STATION FULL
Dump station is filled with components.
弃站
弃站中已装了弃元件。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 7 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Please remove the components manually from
the dump station, then start again.
用手方法清除弃站上的元件后,重新始运行。
Ea00076 COMPONENT COUNT STOP
Component counter has reached the specified number.
Refill components and run again.
Component data Name
Feeder set position
元件数停止
使用的元件数量已达到指定的数量。
在充下列元件后重新始运行。
元件数据 号 名称
送料器安装位置 号
Ea00077 COMPONENT COUNT STOP
Component counter reached specified number.
Refill the components and run again.
Component data Name
Tray start No.
Tray end No.
元件数停止
使用的元件数量已达到指定的数量。
在充下列元件后重新始运行。
元件数据 号 名称
托始号 号
托束号 号
Ea00079 BOARD TRANSFER ERROR
The board was not able to exit from fixed conveyer
on board exit side. Maybe the board stopped on edge
of fixed conveyer on board exit side. Put the board on its
normal position manually.
基板送
生了,基板没有送到下个工序。
出口固定送的出口基板被卡住而停止了送。
Ea00080 BOARD TRANSFER ERROR
1. Moving conveyor cannot move, because there
is a board on the edge of the moving conveyor.
Put the board on its normal position manually.
2. A head may be at a location where a board sensor
can detect it. Please move the head manually to
a location away from board sensors
基板送
1. 因可送中部上有基板,所以不能移可送。
太危,将基板放置在正确的位置上。
2. 感器可能装有感。
将装移至感器不感的位置上。
Ea00083 BOARD TRANSFER ERROR
Board is detected at the entrance sensor, while the
convey out function is active.
The machine can not accept new boards.
Please remove the board detected at the entrance
sensor, and run again.
基板送
然了基板送,但入口感器仍然出了下一个基板。
施基板送的作,不能放入新的基板。
取出入口感器出的基板后,重新始运行。
Ea00084 BOARD TRANSFER ERROR
Board is detected at the entrance sensor, although
maximum number of boards has already been loaded into
the machine.
Please remove the board detected at the entrance
sensor, and run again.
基板送
达到定生枚数的基板已入了片机内的送上,
但入口感器仍然出了下一个基板。
取出入口感器出的基板后,重新始运行。
Ea00085 BOARD TRANSFER ERROR
There is an unexpected board on the conveyor.
If production is continued, more than maximum
number of boards will be completed.
Please remove the board near the entrance.
基板送
超定生枚数的基板,已入了送。
如果装将超出生定数,所以不能生。
取出入口感器出的基板后,重新启运行。
Ea00087 NO COMPONENT FOR USE
All components in alternative loop are no longer
available.
The followings may be the causes:
- Pick-up or recognition error occurred.
- Component counter reached the specified number.
Refill components or check feeders and run again.
Component data
Feeder set position
替代元件循的所有元件已呈不能使用的状。
原因如下。
·吸附或生了。
·使用的元件数量已达到指定的数量。
在充以下元件后,重新始运行。
元件数据 号
送料器安装位置 号
Ea00088 NO COMPONENT FOR USE
No feeder/tray for the component is available.
Supply component if the component is empty,
and check the switch of quick-changer, door of tray units.
Mount data
Component data Name
Feeder set position
下列元件或呈供停止,或呈不能使用状。
如元件用完,充元件,并确一次性料的、
托供装置的柜等。
装数据 号
元件数据 号 名称
送料器安装位置 号
Ea00089 NO COMPONENT FOR USE
Some components are not available.
This can be caused by the followings:
- Pick up or recognition error happened.
- Component counter reached specified number.
- Front or Rear feeder bar is not ready.
Please remove causes and run again.
存在不可使用的元件。
原因如下。
- 生了吸附或。
- 使用的元件数量已达到指定的数量。
- 前或后送料器架脱离。
采取相策,并重新始运行。
Ea00090 ILLEGAL VISION DATA ERROR
Vision recognition aborted because of illegal data.
Possible cause :
Top head and last head of machine pick too big
size component.
Please stop production and change Board data.
数据异常
系因异常数据,而中止了理。
可能由以下原因所致。
·装两端的吸嘴吸附了尺寸大的元件,
并行了。
中断自运行,并修改数据。
Ea00091 CO-PLANARITY CHECK LEAD DETECT ERROR 引脚起出 引脚出

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 8 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
A reflective object was detected at the start
position of scanning.
Please check Body Size in Component Info.
Mount data
Component data Name
Comment
Feeder set position
Pallet set position
Table/Head
描始点存在反光体。
可能元件信息中的外形尺寸有。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
料架抽出位置 号
工作台/Head
Ea00092 CO-PLANARITY CHECK LEAD DETECT ERROR
Failed to detect the end of edge on the last lead.
Please check Body Size in Component Info.
Mount data
Component data Name
Comment
Feeder set position
Pallet set position
Table/Head
引脚起出 引脚出
未能出最后引脚的端。
可能元件信息的外形尺寸的数有。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
料架抽出位置 号
工作台/Head
Ea00093 CO-PLANARITY CHECK LEAD NUMBER ERROR
Failed to detect the specified number of leads.
Mount data
Component data Name
Comment
Feeder set position
Pallet set position
Table/Head
出引脚起 引脚数量
未能出指定数量的引脚。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
料架抽出位置 号
工作台/Head
Ea00094 CO-PLANARITY CHECK LEAD GAP ERROR
The gap between the adjacent leads is out of the
threshold.
Mount data
Component data Name
Comment
Feeder set position
Pallet set position
Table/Head
出引脚起 相引脚高差
相引脚之的高差超出了容。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
料架抽出位置 号
工作台/Head
Ea00095 CO-PLANARITY CHECK LEAD CO-PLANARITY ERROR
Co-planarity level is out of the threshold.
Mount data
Component data Name
Comment
Feeder set position
Pallet set position
Table/Head
出引脚起 引脚起量
引脚起量超出了容。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
料架抽出位置 号
工作台/Head
Ea00096 NO VISION RESULT ERROR
There is no result of recognition from
vision system.
果出
未能出系的果。
Ea00097 NOZZLE RECOGNITION ERROR
Intensity of Component pole is not enough at threshold
level. Nozzle is recognized as a component.
Please check nozzle and clean it.
Mount data
Component data Name
Comment
Feeder set position
Table/Head
吸嘴
像的果,元件极部的亮度
没有达到元件亮度的要求。
可能把吸嘴当成元件了。
并清装的吸嘴。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
工作台/Head
Ea00099 VISION SYSTEM TIMEOUT ERROR
The result of recognition is TIMEOUT.
Mount data
Component data Name
Comment
Feeder set position
Table/Head
系超
因等待像理的果,而致系超。
装数据 号
元件数据 号 名称
注
送料器安装位置 号
工作台/Head
Ea00100 EMERGENCY STOP FUNCTION IS ACTIVE.
Check for safe conditions and
press the READY button to
re-enable the machine.
The "EMERGENCY STOP" light will go off.
<Check items for READY>
"EMERGENCY STOP"s, Covers of Machine/Tray Changer,
Area sensors of Machine/FES, etc
急停机功能于有效状。
在确安全的基上,按解除急停机按。
如解除急停机成功,亮着的色指示灯会熄。
<解除急停机需确的目>
急停机、主机/托交器的机盖、
主机/一次性料的区域感器等。
Ea00101 Please make sure that the "EMERGENCY STOP" is ON.
When you wish to turn off the power,
按下急停机按。
在切断源前,使机器于急停机状。