Cor. amount
Min. Cor.
Max. Cor.
校正量
最小校正
最大校正
Ea00413 DISPENSE CORRECTION ERROR
The amount of Min and Max correction of dispense
correction is inaccurate.
When correction is "1.0000", the value which becomes
an error is contained in Min and Max correction of
dispense correction.
Please adjust the value of Min and Max correction of
machine setting-dispense correction to straddle "1.0000".
Head number
Cor. type
点胶校正
点胶校正的最小校正、最大校正不正确。
点胶校正的最小校正、最大校正的校正 1.0000 ,
含有引起的。
整[机器置]-[点胶校正]画面的最小校正、最大校正,
使其跨越 1.0000。
Head 号 号
校正型
Ea00414 DISPENSE CORRECTION ERROR
The amount of Min and Max correction of dispense
correction is inaccurate.
The value with the larger Min correction is contained
from Max correction.
Please adjust Min and Max correction of machine setting.
Head number
Cor. type
点胶校正
点胶校正的最小校正、最大校正不正确。
最小校正比最大校正大。
整[机器置]-[点胶校正]画面的最小校正、最大校正。
Head 号 号
校正型
Ea00434 Board DATA Dot Dispensing Pos. Warning!
Dot dispensing position is outside Pcb.
If you start production in this condition,
a head unit may be broken. Please check Pcb data again.
Dot Dispense data
基板程序 正式点胶位置 警告
正式点胶位置偏离了基板。
如行,点胶与送装置生干,
可能会造成破。
重新确数据。
正式点胶数据 号
Ea00435 BOARD DATA Pre Dispensing Height Warning!
Pre dispensing Height is too low.
If you execute auto-running in this condition,
a head unit may be broken. Please check data again.
1)Lower end position is below the normal height + 0.5mm.
2)Z height for next job is below the normal height - 0.5mm.
3)Lower end position is above Z height for next job.
4)Z height for next job is above upend position.
Pre Dispense data
基板程序 点胶高度 警告
点胶的高度太低。
如行,点胶可能会破。
重新确置。
·下降目位置,低于基准高度+0.5mm 。
·下次作容高度,低于基准高度-0.5mm。
·下降目位置,高于下次作容的高度。
·下次作容高度,高于上升目位置。
点胶数据 号
Ea00436 BOARD DATA Dot Dispensing Height Warning!
Pre dispensing Height is too low.
If you execute auto-running in this condition,
a head unit may be broken. Please check Pcb data again.
1)Lower end position is below the pcb height + 0.5mm.
2)Z height for next job is below the pcb height - 0.5mm.
3)Lower end position is above Z height for next job.
4)Z height for next job is above upend position.
Dot Dispense data
基板程序 正式点胶高度 警告
正式点胶的高度太低。
如行,点胶可能会破。
重新确置。
·下降目位置, 低于基板面高度+0.5mm 。
·下次作容高度,低于基板面高度-0.5mm。
·下降目位置,高于下次作容的高度。
·下次作容高度,高于上升目位置。
正式点胶/作流程数据 号
Ea00437 BOARD DATA ERROR
Illegal setting of "Retry Seq." in Board Info.
If you want to use "Part Group No." in Part Info.,
change "Retry Seq." to "Group" or "Block".
基板程序
重新行方式"自"。
使用元件号,把基板信息的
重新行方式置""或是"拼"。
Ea00438 BOARD DATA ERROR
Board Size Z is an illegal value.
Please check it and input the correct value.
基板程序
基板外形 Z(基板厚度)的置异常。
按照基板,置正确的基板厚度。
Ea00439 BOARD DATA ERROR
Trans Height is outside moving area.
Axes
基板程序
基板送高度在作范外。
名称
Ea00441 BOARD DATA ERROR
Only 'STOP 'Error Sequence of mark data are
available for Board Fiducial.
Please check and correct the mark data.
基板程序
基板基准不能指定停止以外的理。
修改数据。
Ea00442 BOARD DATA ERROR
Only 'STOP 'Error Sequence of mark data are
available for Point Fiducial.
Please check and correct the mark data.
Mount data
Fiducial data
Mark data
基板程序
点基准不能指定停止以外的理。
修改数据。
装数据 号
基准数据 号
数据 号
Ea00443 PLEASE CHECK FOR ANY ILLEGAL RUNNING CONDITION
There is possibility that hits components.
注意: 运行条件异常
运行条件置不适合生。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 25 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Because the mount height offset is large.
If all are OK, please continue.
确后,如果没,。
因装高度偏差量大,元件可能干。
Ea00444 DATA CHECK ERROR
Unknown error.
程序
是原因不明的。
Ea00445 BOARD DATA ERROR
Too many mount data.
基板程序
装数据数多于定数。
Ea00446 BOARD DATA ERROR
Too many dot-dispense data.
基板程序
正式点胶数据数多于定数。
Ea00447 BOARD DATA ERROR
Too many pre-dispense data.
基板程序
点胶数据数多于定数。
Ea00449 BOARD DATA ERROR
The nozzle selected in component info. is not
available for stamping action.
Select appropriate one.
Component data Name
基板程序
在元件信息中指定使用的吸嘴,
不能行浸胶作。
适用浸胶的吸嘴。
元件数据 号 名称
Ea00452 DATA CHECK ERROR
Current Board data has some data error.
Please read same Board data, and correct wrong data.
程序
当前入的基板程序,没有行程序。
重新入基板程序,修改程序之。
Ea00453 SPECIAL DUMP BACK WARNING
The function "Sp. Dump Back" cannot be used for
Ext. Tray Changer like YTF80W.
Please check "Dump Way" in Component Information.
特殊返理
YTF80W 等外部托交器不能使用[特殊返理]的弃方法。
更改元件信息中弃方法的置。
Ea00454 BOARD DATA ERROR
CO-PLANARITY CHECK is available only when the datum
angle is 0 degree.
Mount data
Component data Name
基板程序
形状基准角度在 0 度以外的状下,
不能施引脚起出。
装数据 号
元件数据 号 名称
Ea00455 Board DATA ERROR
Fiducial skip function can not be used
with tray changer unless it is accompanied
with the all fiducial check function.
基板程序
只要基准跳功能不与全基准功能并用,
就不能同使用托交器。
Ea00456 BOARD DATA ERROR
At the following head,
the vision type of the dispense nozzle is not defined.
Please set the type.
Head Number No.
基板程序
没有置下列点胶号的点胶嘴的校正型。
置校正型。
点胶号 号
Ea00457 BOARD DATA ERROR
At the following head,
the vision type of the dispense nozzle is illegal.
The dispense vision data for the type does not exist.
Please change to the correct type.
Head Number No.
基板程序
下列点胶号的点胶嘴的校正型不正确。
所置的校正型用的点胶校正数据不存在。
更改正确的校正型。
点胶号 号
Ea00458 TRAY PRECEDE ERROR
In case of component supply from ATS,
if the Dump way set to [Sp.Dump Back],
the Tray Precede function cannot be used.
Please set Tray Precede to [Not Use].
托先
ATS 元件的弃方法置特殊返理,
不能使用托先功能。
把托先置[不行]。
Ea00459 CONFIRMATION OF BLOW MODE
Blow Mode is not set to "Normal".
This could have a negative influence on production.
Please confirm the Blow mode setting.
装的排气方式确
[机器置]1 画面中装的排气方式不是"普通"。
可能无法在最佳条件下行生。
Ea00460 Multi-Macs Data Error
Multi-Macs data in Machine Data is not correct.
This condition is not good for mounting accuracy.
Please adjust Multi-Macs data in Adjust Utility.
Multi-MACS 数据
[机器置]画面所置的 Multi-MACS 的校正基准异常。
如运行,不能正常生。
在[机器置]画面重新整 Multi-MACS 校正基准。
Ea00461 PLEASE CHECK FOR BOARD SIZE HEIGHT
Board Size Height is "0".
If OK, please continue.
注意: 基板厚度数据异常
在基板程序中所置的基板厚度的数"0"。
确后,如没有,运行。
Ea00462 BOARD DATA Pre-Dispensing Pos. Warning!
Pre-Dispensing position is outside the Pcb or Dot-Station.
If you start production in this condition,
a head unit may be broken. Please check Board data again.
Pre-Dispense data
基板程序 点胶位置 警告
点胶坐在基板或打点站上的范外。
如行,点胶可能与送装置等生干,造成破。
重新确数据。
点胶数据 号
Ea00463 BOARD DATA Pre-Dispensing Pos. Warning!
Pre-Dispensing position added Y+20mm for checking is
outside the Dot-Station.
If you start production in this condition,
a head unit may be broken. Please check Board data again.
基板程序 点胶位置 警告
校正量确作用的点胶坐在打点站上的范外。
如行,点胶与送装置等可能生干,造成破。
重新确数据。
点胶数据 号

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 26 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Pre-Dispense data
Ea00464 BOARD DATA ERROR
In Pre-dispense data,
"Feedback" and "Exec." are inputted at the same line.
"Feedback" should be inputted with "Check" or "Skip".
Pre-Dispense data
基板程序
在点胶数据中,同指定了[校正]和[行]。
如指定[校正],指定[]或[跳]。
点胶数据 号
Ea00465 STATIC COMPONENT WARNING
Static Components are not supported on VGOS,
default parts data will be used instead.
This parts data may not be the same as
the intended Static Components definition.
Please check the components data is correct.
Comp number No.
Comp Name
注意: 固定元件使用警告
元件信息中存在使用固定元件的元件。
在 Xg 系列中,因不支持固定元件,
所以默数据。
确下列元件信息。
元件号 号
元件名称
Ea00466 BOARD DATA ERROR
Illegal component shape data.
Body Size or Body Height or Search Area is 0.
Mount data
Component data Name
基板程序
元件形状信息的外形尺寸 X、Y、元件高度、
出范"0""。
装数据 号
元件数据 号 名称
Ea00467 BOARD DATA ERROR
Too many Height Correction Data.
基板程序
内存的分配已失。
高度校正数据的数量多。
Ea00471 TIMEOUT ERROR
Cannot receive a signal from SEQUENCE UNIT;
( Waffle Tray Changer, Special Feeder etc... )
UNIT No.
供装置超
供装置(蜂状托交器、其他供装置)没有答信号。
要求更元件(托)的指令,没有答信号。
可能是由于没有供元件(托)而使得无法入 READY 状
等象造成。
装置号
Ea00472 SEQUENCE UNIT ERROR
An error signal was received from SEQUENCE UNIT,
( Waffle Tray Changer, Special Feeder etc... )
Please check it, and solve the problem.
UNIT No.
供装置
从供装置(蜂状托交器、其他供装置),
入了信号。
确供装置是否有。
装置号
Ea00473 BOARD DATA ERROR
In Mount/Sequence Info., there is an illegal mode parameter.
Please, check the following data.
Mount data
基板程序
在[装信息][作流程信息]中指定了异常"方式",确。
装数据 号
Ea00474 BOARD DATA ERROR
There is an invalid mark data referenced from Mount data.
Please, check the following items:
- The mark data does not exist.
- The mark data number is illegal value.
- Mark Type is not Check1 or Check2.
- Src.Offset and Diff.Pos are active at the same time.
Mount data
Mark data Name
基板程序
在[装信息]中指定的数据异常。
可能是由以下原因所致,确。
·使用了不存在的数据。
·指定的号在定外。
·数据的功能在[ 1]和[ 2]之外。
·同使用了数据的[出偏移量]和[位置公差]。
装数据 号
数据 号 名称
Ea00475 BOARD DATA ERROR
There is an invalid Dot-dispense data referenced
from Mount-Info.
Please, check the following item:
- is there Dot-dispense data referenced from Mount data?
Mount data
基板程序
在[装信息]中指定的正式点胶数据异常。
以下可能是造成异常的原因,确。
·使用了不存在的正式点胶数据。
·指定的正式点胶号在定外。
装数据 号
Ea00476 BOARD DATA ERROR
[StationNo] of component info is wrong.
Component data Name
基板程序
在[元件数据]的[浸胶]画面中指定的装置号异常。
以下可能是造成异常的原因,确。
·在装工作台中指定了不存在的装置号。
元件数据 号 名称
Ea00477 BOARD DATA ERROR
Mark position in the mount/sequence data is outside moving area.
Mount data
Axes
基板程序
在[装信息]或[作流程信息]中所指定的/位置
在作范外。
装数据 号
名称
Ea00478 BOARD DATA ERROR
There is an invalid head number in Mount-Info or Sequence-Info,
or this head can not do dot-dispense.
Mount data
基板程序
在[装信息]或[作流程信息]中所指定的 Head 异常。
可能由下列原因造成,确。
·指定的 Head 号在定外。