Comparison Table ( English - Chinese ) VGOS V2.46STD R1.000 30 / 237 Copyright (C) 2009 Y amaha Motor Co., Ltd. All Rights Reserved. Code Code Code Code Englis h Englis h Englis h Englis h Chinese Chinese Chinese Chinese…

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 29 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Machine 机器名称
Ea00605 DATA ERROR
The nozzle is not distributed to the head.
Machine
-Some nozzles cannot pick the interfering component.
Check the nozzle type and body size of each component.
- Not enough nozzles are available.
Check the nozzle number and Head Spec. inf..
数据
吸嘴的分配已失。
机器名称
·了可能与近装相干的元件和吸嘴型。
确各元件的吸嘴型。
·因吸嘴数量不足,不能全部装装吸嘴。
确吸嘴数和 Head 格信息的置。
Ea00606 DATA ERROR
The setting of Head Spec. inf. is different from the
one of machine data.
Machine
Head No.
Check the setting of "Head Offset","Nozzle Station"
in "MCH_DATA" and "HEAD SPEC. INF.".
数据
Head 格信息与机器信息的置相互矛盾。
机器名称
装号 号
确机器信息中的装偏移量、吸嘴交站、
以及 Head 格信息的置。
Ea00607 COMPONENT DATA ERROR
The setting of Pos. Definition is different
within one or more multistick feeders.
The multisticks on below set positions should
all be set to same Pos. Definition type [Teaching]
or [Relative].
Feeder Set No.
元件数据
使用多杆式送料器的元件的送料器位置算的置有矛盾。
下列送料器安装位置中存在置[示教]和[相示教]
的元件。当您想移送料器位置,更改[相示教],
不想移送料器位置,更改[示教]。
送料器安装位置 号
Ea00608 DATA ERROR
The settings for nozzle changer in OPTION CONFIG.
and for the heads in HEAD OFFSET do not match.
Machine
If a nozzle changer is present,
at least one head should be AutoNzlChg.
If not, no head should be AutoNzlChg.
数据
在机器构成中的构成的吸嘴交装置和 Head 偏移量
置中的 Head 的置相互矛盾。
机器名称
当吸嘴交装置置有的候,Head 偏移量置中必
有一个以上的自吸嘴交 Head。
如果置没有,不能有自吸嘴交的 Head 存在。
Ea00609 DATA ERROR
The set number of multistick is set to 0.
Set the feeder set number.
Component Name
元件数据
多杆式送料器的安装位置 0。
指定多杆式送料器的安装位置。
元件数据 号 名称
Ea00610 Failed to access feeder data file. 使用送料器个数的数据文件失了。
Ea00611 Failed to access nozzle data file. 使用吸嘴数的数据文件失了。
Ea00612 Failed to execute non stop expansion.
Check points:
1.The feeder set position of "Static Components"
or fixed Board data.
2.The setting of feeder plate setting information.
3.If executed "PRECEDENCE",change to "CONSIDERATION"
and setting the "NON STOP LIST".
4.If executed "CONSIDERATION", check the setting of
the "NON STOP LIST".
替代展中存在未分配的送料器。
要点:
1.固定元件、固定基板内的元件的安装位置。
2.送料器架信息。
3."替代展先",指定"考替代展"
并置"替代展取消列表"。
4."考替代展",修改"替代展取消列表"。
Ea00613 The name of component and one of static component
do not match.
The name of below component and one of
static component that is referenced from it
should be exactly the same.
Machine
Component Name
固定元件与元件名称不同。
下列元件从固定元件中参照了固定元件,
但元件名称不同。
参照固定元件,元件名称必一致。
机器名称
机器信息 号 名称
Ea00614 The Static component data that is referenced from
below component data does not exist.
Machine
Component Name
1.The Static component data is masked
by "FIXED COMP. MASK"
2.The Static component data is not existing.
3.The Static component data is existing,
but component name is deleted.
4.In case of YGOS, It can't use Static component.
Please Set "FixCompReferece 0".
下列元件在参照固定元件中的固定元件,但固定元件
并不存在。
机器名称
元件数据 号 名称
要点:
·目的位置的固定元件被固定元件屏蔽程序屏蔽了。
·未登目的地的固定元件(不存在数据)。
·没有固定元件(数据存在,但元件名称已被除)。
·因 YGOS 不能使用固定元件,所以必将固定元件参照置 0。
Ea00620 DATA ERROR
No component data exists.
Machine
Board
Component Name
数据
不存在指定的元件数据。
机器名称
基板名称
元件数据 号 名称
Ea00621 DATA ERROR 数据

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 30 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
No fiducial data exists for the mount data.
Machine
Board
Mount
Fiducial
不存在装数据中所指定的基准数据。
机器名称
基板名称
装数据
基准数据
Ea00622 DATA ERROR
No mark data exists.
Machine
Board
Mark
数据
不存在指定的数据。
机器名称
基板名称
数据
Ea00623 DATA ERROR
No badmark data exists for the mount data.
Machine
Board
Mount
Badmark
数据
不存在装数据中所指定的坏板数据。
机器名称
基板名称
装数据
坏板数据
Ea00624 DATA ERROR
No fiducial data exists for the dispense data.
Machine
Board
dispense
Fiducial
数据
不存在点胶数据中所指定的基准数据。
机器名称
基板名称
点胶数据
基准数据
Ea00625 DATA ERROR
No badmark data exists for the dispense data.
Machine
Board
dispense
Badmark
数据
不存在点胶数据中所指定的坏板数据。
机器名称
基板名称
点胶数据
坏板数据
Ea00630 FIDUCIAL DATA ERROR
The sub-data for 4 point-fiducial is not
shown in mount or dispense data.
Machine
Board
Mount, Dispense
Fiducial
基准数据
在装数据或者正式点胶数据中所指定的基准数据是
4 点基准的子数据。
机器名称
基板名称
装、点胶数据
基准数据
Ea00631 FIDUCIAL DATA ERROR
Mount data shows the main data
for 4 points fiducial.
Next line must be the sub-data.
Machine
Board
Mount
Fiducial
基准数据
在装数据中所指定的基准数据是 4 点基准的
主数据。
机器名称
基板名称
装数据
基准数据
Ea00636 DATA ERROR
Although the nozzle had been defined to be available
in [HEAD SPEC.INF.], the nozzle is not given
for this head in "Nozzle Station" in Machine Data.
Modify spec. definition in [HEAD SPEC.INF.]
Machine
Head No.
Nozzle TYPE
数据
Head 格信息中置可使用的吸嘴不在吸嘴交站上,
在 Head 格信息中将其更改不可使用。
机器名称
Head 号 号
吸嘴 型
Ea00642 Dispense machine does not exist. 不存在有点胶功能的机器。
Ea00643 Failed to open dispense information. 点胶信息文件的打失了。
Ea00645 CAUTION:
Now going to convert the data
from "Note" to "Exec" in Mount, Block repeat,
Local fiducial and Local badmark.
"Exec" data will be deleted.
Press the [ENTER] key to execute.
Press the [ESC] key to cancel this operation.
警告:拼原,或者拼再展。
将基板信息、装信息、拼制、局部基准、
局部坏板的"参考"数据成"行"。
注意,将除以前所的"行"数据。
拼原、或者拼再展
行,按[ENTER]。
中止,按[ESC]。
Ea00647 "Note" data needed to execute the convert
from block converted data to original data does not
exist.
Machine
不存在拼原所必需的"参考"数据。
机器名称
Ea00648 POINT DATA NUMBER ERROR
Amount of point data obtained as a result of block
conversion exceeded .
Too many data.
Reduce the amount of data.
Allowed amount of data for 'Mount Data',
'Component Info.', Mark Information', 'Block Repeat',
坐数据数
算的果,坐数据已超。数据多。
因自运行可能会造成数据入,所以减少数据。
装信息、拼制、基准、局部坏板、点胶、
正式点胶等的合上限。

Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 31 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
'Fiducial Mark', 'PreDispense' and 'DotDispense'
is limited to .
Ea00649 There is only one "Exec" data in Block repeat. 在拼原数据中,存在一个"行"数据。
Ea00650 BOARD DATA ERROR
No alignment module for the component.
Machine
Board
Component Name
基板程序
不存在适合元件的装置。
机器名称
基板名称
元件数据 号 名称
Ea00651 BOARD DATA ERROR
No dump station for the component.
Or the table of the dumpstation is different from
the one for the component.
Machine
Board
Component Name
基板程序
在元件数据中指定的弃站不存在、或安装在并非元件所安装的
工作台上。
机器名称
基板名称
元件数据 号 名称
Ea00653 DOT DISPENSE SORT TIMEOUT ERROR
Dispense sort was interrupted by time out error.
Dispense sort was finished,
but it contains data that stopper
may interfere with other dispense data.
Please check the following:
*Illegal Diameter, Stopper and Pitch data
of the nozzle spec.
点胶排序 超
因点胶排序程序超而中止了理。
数据,有可能造成板干已涂好的胶粘。
由下列原因之一所致
·吸嘴格信息的直径、板、距的置不适当。
·存在有可能造成板干已涂好的胶粘的数据。
Ea00654 DISPENSE GENERATOR ERROR
The recognition type of the following component
number is not suitable for this function.
On this function using SOLDER, please select the
recognition type which can define the LEAD POSITION
and LEAD WIDTH.
Comp. Data No.
<Unsuitable type>
Sp.Quad, AsMark, Gravity
膏点胶展
下列元件的型,不适合膏点胶的展。
行膏点胶的展,能定引脚位置、
大小的型。
元件数据 号
<不能的型>
特殊方形、型、重心出
Ea00658 COMMAND ERROR
1.[ADJUST ASSISTANT] command is not available
for a component that uses "FixCmpRef."
2.[DRAW THE SHAPE(CMP)] command is not available
for a component that uses "FixCmpRef."
指令
使用固定元件参照的元件不能行下列指令。
1.[助整]
2.[定形状示(元件)]
Ea00659 Impossible to quote component details
from Database.
CheckPoints:
1.[SET FROM DATABASE] is not available
for a component that uses "FixCmpRef."
2.[SET FROM DATABASE ALL] is not available
for STATIC_COMPONENTS__.
3.[SET FROM DATABASE] is impossible for
components with Database No. "0"
不能从数据制信息。
要点:
1.使用固定元件参照的元件不能行数据
信息制。
2.于固定元件信息=STATIC_COMPONENT,禁止
全部制数据信息。
3.不入数据号,不能从数据制信息。
Ea00660 DATA ERROR
Failed to quote component details
from Database.
Component
specifies an illegal database number.
CheckPoint:
DataBase Number
数据
从数据制数据失了。
元件数据 号的
数据号的数据无法入。
要点:
数据号
Ea00661 DATA ERROR
Failed to quote mark details
from its Database.
Mark
specifies an illegal database number.
CheckPoint:
DataBase Number
数据
从数据制数据失了。
数据 号的
数据号的数据无法入。
要点:
数据号
Ea00662 DATA ERROR
Failed to set up component or mark information from
Database. MAIN WINDOW should be component info. or
mark info. Or indicated database may not exist.
Or failed to set up component or mark information
into Database. The indicated record may be protected
by pass word level.
数据
从数据制信息或将信息制至数据的作失了。
可能是由以下原因所致。
1.主画面在元件信息或信息之外。
2.指定的数据信息不存在。
3.因密原因,禁止写入数据。
Ea00663 FILE ERROR
Failed to read Board data.
文件
基板程序的入失了。
Ea00664 DATA ERROR
Failed to set up Fixed feeders at set position.
Component Name
固定送料器的置有。
元件数据 号 名称
元件因有固定元件参照、或不行最化、或分配条件由送料器固定,