Ea01311 MULTI-MACS ERROR
Multi-Macs recognition error was
happened during auto-running.
It is possible to continue auto-running,
but this error condition is not good for
mounting accuracy.
Please check recognition condition of
Multi-Macs in Adjust window.
Multi-MACS 󲢛󳇮󲣄
运行中生了 Multi-MACS 󲢛󳇮󲣄
在此状下可以󱮼󱯂运行,但是
󲨉装精度可能会降低。
󲣌󲱚󲣘整确󲡹 Multi-MACS 的状
Ea01314 LASER HEIGHT DISPLACEMENT TIMEOUT ERROR
Fail to get the result of laser height
displacement.
激光高度󰨠量超󰋋󳇮󲣄
激光高度󰨠量已失󲧺
Ea01315 LASER HEIGHT DISPLACEMENT ERROR
A = B - C
B : the maximum result
C : the minimum result
The A value is over the limit.
Local Height
激光高度󰨠󳇮󲣄
󰨠󱮨果(最大·最小的差)已超󲲜󲢍的范
高度校正数据
Ea01316 LASER HEIGHT DISPLACEMENT ERROR
The average of results is over the limit.
Local Height
激光高度󰨠󳇮󲣄
󰨠󱮨果(平均)已超󲲜󲢍的范
高度校正数据
Ea01317 BOARD DATA ERROR
There is a wrong local height number referenced
from sequence data.
Sequence Info.
Local Height
基板程序󳇮󲣄
作流程信息中指定的高度校正号󱓖异常。
可能由以下原因造成,󲣌󲡹
·参照了不存在的高度校正数据。
作流程信息
󰓜󲢅󱓖
Ea01318 NOZZLE HEIGHT DISPLACEMENT ERROR
Fail to measure the nozzle height.
The input of Touch-Sensor is not good.
Q) Is Touch-Sensor connected ?
Is Touch-Sensor active ? etc...
Machine couldn't get result by moving head.
Q) Check the XYZ position of Touch-Sensor. etc...
吸嘴高度󰨠󳇮󲣄
吸嘴高度󰨠量已失󲧺
·触摸式感器的󲱨入异常
→触摸式感器没有󲲳接。
触摸式感器已󰀴
·󲍒󰨠量,但未能󰨠到吸嘴高度。
→触摸式感器的坐󰓜(XYZ)󳇮󲣄
Ea01343 BOARD RELEASE ERROR
Failed to release the Board.
基板固定解除󳇮󲣄
定位󳅝󳕋󳅝等不能正确作。
Ea01347 DIP TEST ERROR
Can not execute "Dip Test",
because of following reasons;
vacuum valve is OFF on the head.
No use the turn blader in option config.
Not the mount head.
浸胶󰨠󲢪󳇮󲣄
未能浸胶。
可能由下列原因所致,󲣌󲡹
·要在未做吸气的 Head 󲲰行浸胶。
·󲢓置旋󲱁浸胶装置。
·要在󲨉装以外的 Head 󲲰行浸胶。
Ea01352 ERROR! Failed to write "TRACKING-DATA".
Code %d
0 to 8: Failed to convert any data.
( 0:HEADER, 1:VERSION, 2:POSITION, 3:ACTIVE,
4-5:XY COUNTER, 6:COR., 7:FLAGS, 8:HOOTER )
10 : The Number of area is different between
BOARD-DATA and TRACKING-DATA.
11 : BOARD DATA has no local areas.
12 : Data shortage in TRACKING-DATA.
13 : Failed to open TRACKING-DATA or temporary file.
跟踪信息的写入失󲧺了。
󳇮󲣄󲢻󱮛󱓖 %d
0~8: 跟踪信息的󲱁󰀷已失󲧺
( 0: 1:版本, 2:位置, 3:全体󰓜志, 4-5:个数,
6:校正量,7:NG 󰓜志,8:尾部 )
10 : 基板程序和跟踪信息的区域数不一致。
11 : 基板程序的区域数异常。
12 : 跟踪信息的数据数不足。
13 : 跟踪信息,󰋋文件的打󲧺了。
Ea01353 ERROR! Failed to read "TRACKING-DATA".
Code %d
0 to 8: Failed to convert any data.
( 0:HEADER, 1:VERSION, 2:POSITION, 3:ACTIVE,
4-5:XY COUNTER, 6:COR., 7:FLAGS, 8:HOOTER )
10 : The Number of area is different between
: BOARD-DATA and TRACKING-DATA. It has the possib-
: ility that local fid or bad is not "practice".
11 : BOARD DATA has no block local areas.
12 : Data shortage in TRACKING-DATA.
13 : Failed to open TRACKING-DATA or temporary file.
跟踪信息的󲣐入失󲧺了。
󳇮󲣄󲢻󱮛󱓖 %d
0~8 : 跟踪信息的󲱁󰀷󲧺了。
( 0: 1:版本, 2:位置, 3:全体󰓜志, 4-5:个数,
6:校正量,7:NG 󰓜志,8:尾部 )
10 : 基板程序和跟踪信息的区域数不一致。
: 局部基准󰓜󲢅或局部坏板󰓜󲢅可能
: 不是"行"状
11 : 基板程序的拼·区域数异常。
12 : 跟踪信息的数据数量不足。
13 : 跟踪信息、󰋋文件的打󲧺了。
Ea01354 TRANSFER ERROR
TRANSFER UNIT has not responded to "FINISH" signal.
󳇮󲣄
送装置没有答机器的[作󱮨束]信号。
Ea01355 TRANSFER ERROR
Unexpected signal "WORK OFF" is detected.
󳇮󲣄
在没有󳕙料到的󰋋刻,[作始]信号 OFF
Ea01356 BOARD DATA ERROR
If the function of "Timer Pre-Dispense" is available,
基板程序󳇮󲣄
使用󲡶󰋋管理型的󳕙点胶󰋋
Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 52 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
the parameter "PreDsp CHECK" in "Dot Station" must
be "USE".
󲣌将机器󲢓置的[校正量确󲡹作]
󲢓[行]。
Ea01357 BOARD DATA ERROR
For using "TRACKING-DATA", parameters of Board DATA
must be as followings.
Board Fiducial : NOT USE
Block Fiducial : USE
Local Fiducial : USE
Board Badmark : NOT USE
Block Badmark : NOT USE
Local Badmark : USE
基板程序󳇮󲣄
使用跟踪信息󰋋
基板程序必󳕐按下列方式󲢓置。
基板基准󰓜󲢅 : 不使用
基准󰓜󲢅 : 使用
局部基准󰓜󲢅 : 使用
基板坏板󰓜󲢅 : 不使用
坏板󰓜󲢅 : 不使用
局部坏板󰓜󲢅 : 使用
Ea01358 Block Fiducial Recognition Error
The distance of block fiducials is too different
from the distance of theoretical block fiducials.
基准󰓜󲢅󲢛󳇮󲣄
基准󰓜󲢅󲢛󱮨,两点󳋉的理󲢏距离
󳌚距离偏离了既定
Ea01359 BOARD DATA ERROR
There is a mark data set as [SKIP] ,[SELECT] or
[GROUP SELECT] in Error Sequence.
This function can not be used with tray changer.
基板程序󳇮󲣄
󰓜󲢅信息󲢛后的理中,󲳞
[确󲡹]、[跳󲲜]、[󱮙󲡹]等。
󲲮些功能,与托󱎭󰀷器不能同󰋋使用。
Ea01360 HALFWAY CONTINUE ERROR
There is no Board is detected on mounting position.
中途始运行󳇮󲣄
󲍒󲳞了[中途始运行]方式,
󲨉装位置上并不存在基板。
Ea01361 FILE OPERATION ERROR
In following situation, the error occurred.
SCENARIO %s
MODULE %s
FILE %s
ACTION %s
Please check the reason and make it correct.
Retry?
文件操作󳇮󲣄
在下列状况下生了󳇮󲣄
脚本 %s
%s
文件 %s
操作 %s
󲣌󰒺󳇮󲣄原因,采取相措施。
是否重󲢪一次?
Ea01362 SCENARIO EXECUTING ERROR
During executing Scenario, the error occurred.
SCENARIO %s
SVS ERROR %s
Process cannot be continued because SVS system has
some problem.
Please check the reason of SVS ERROR.
Please reset Auto-Running and restart Auto-Running
on Machine.
脚本󰋋󳇮󲣄
在下列行脚本中生了󳇮󲣄
脚本 %s
SVS 󳇮󲣄 %s
SVS 󱮴生了某󱚢󳇮󲣄
所以不能󱮼󱯂󲲰理。
󲣌󰒺明上述 SVS 󳇮󲣄的原因。
󲣌位自运行,并重新始运行。
Ea01363 SCENARIO STARTING ERROR
When starting Scenario, the error occurred.
SCENARIO %s
SVS ERROR %s
Process cannot be continued because SVS system has
some problem.
Please check the reason of SVS ERROR.
Please reset Auto-Running and restart Auto-Running
on Machine.
脚本󰋋󳇮󲣄
下一个脚本󰋋生了󳇮󲣄
脚本 %s
SVS 󳇮󲣄 %s
SVS 󱮴生了某󱚢󳇮󲣄,不能󱮼󱯂
󲲰理。󲣌󲣘󰒺上述 SVS 󳇮󲣄的原因。
󲣌位自运行,并重新始运行。
Ea01364 TRAY PARTS ERROR
No parts for use.
Please check it and make it correct.
Mount data
Component data Name
Palette No
󱎭元件󳇮󲣄
没有可以使用的元件。
󲣌󰖕󰒺以下信息后,󲔺充元件。
󲨉装数据
元件数据 名称
料架号󱓖
Ea01367 BOARD DATA ERROR
In Mount Info., adjusting resistor's reference for LED
is not found.
Please, check the following data.
Mount data
基板程序󳇮󲣄
没有指定[󲨉装信息]LED 󲣘󱈊阻。
󲣌󲡹
󲨉装数据
Ea01368 BOARD DATA ERROR
In Mount Info., this adjusting resistor not found.
Please, check the following data.
Mount data %d
Reference %s
基板程序󳇮󲣄
不存在[󲨉装信息] 中指定的󲣘󱈊阻的󲨉装信息。
󲣌󲡹
󲨉装数据 %d
󰔌名称 %s
Ea01369 BOARD DATA ERROR
In Mount Info., rank of this adjusting resistor does
not exist.
Please, check the following data.
Reference %s
Rank No %d
基板程序󳇮󲣄
没有指定[󲨉装信息]󲣘󱈊阻的等󱭼
󲣌󲡹
󰔌名称 %s
󱭼󱓖 %d
Comparison Table ( English - Chinese )
VGOS V2.46STD R1.000 53 / 237 Copyright (C) 2009 Yamaha Motor Co.,Ltd. All Rights Reserved.
Code
CodeCode
Code
English
EnglishEnglish
English
Chinese
ChineseChinese
Chinese
Ea01370 BOARD DATA ERROR
In Mount Info., rank of this adjusting resistor is
out of allowed range.
Please, check the following data.
Mount data %d
Rank No %d
基板程序󳇮󲣄
[󲨉装信息]󲣘󱈊阻的等󱭼指定不正确。
󲣌󲡹
󲨉装数据 %d
󱭼󱓖 %d
Ea01371 SVS Data check
LED (Rank is specified.) on REAR-FEEDER PLATE is
unacceptable condition to use.
Check and correct the indication of the status
area of the machine.
--Mounted LEDs are not found.--
󲢓置信息确󲡹
送料器架上没有可以使用的 LED。
󲣌󲡹󰓤区域的󰌓示后,采取相措施。
󲣌在后 LED 可以使用后,重新始自运行。
Ea01387 SCENARIO STORING ERROR
Storing new scenario, error occurred.
New Scenario %s
Current Scenario %s
New Scenario may be lost.
脚本登󰋋󳇮󲣄
下个作的脚本󰋋生了󳇮󲣄
新脚本 %s
󱂅脚本 %s
新脚本可能已󱮤消失。
Ea01394 MARK DETECTION ERROR
Failed to detect defined mark.
2Fid.Correction No. :
󰓜󲢅󰖕󳇮󲣄
无法󰖕出基准󰓜󲢅
基准󰓜󲢅一次性󲢛:
Ea01395 MARK AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter
is out of tolerance.
2Fid.Correction No. :
󰓜󲢅󱛄、周󳉔󳇮󲣄
在指定的面󱛄和周󳉔的公差范
无法󰖕出基准󰓜󲢅
基准󰓜󲢅一次性󲢛:
Ea01396 MARK DETECTION ERROR
A part of the fiducial mark is located out of
the specified search area or the fiducial
correction angle is too big.
2Fid.Correction No. :
󰓜󲢅󲢛󳇮󲣄
󰖕出的基准󰓜󲢅的一部分超出了搜索区域。
或者基准󰓜󲢅校正角度异常大。
基准󰓜󲢅一次性󲢛:
Ea01397 MARK SHAPE ERROR
Failed to detect a fiducial mark of the
specified shape
2Fid.Correction No. :
󰓜󲢅形状󳇮󲣄
无法󰖕出指定形状的基准󰓜󲢅
基准󰓜󲢅一次性󲢛:
Ea01398 MARK AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter
is out of tolerance (Special)
2Fid.Correction No. :
󰓜󲢅󱛄、周󳉔󳇮󲣄
在指定面󱛄和周󳉔的公差范
无法󰖕出基准󰓜󲢅。(特殊形状)
基准󰓜󲢅一次性󲢛:
Ea01404 FILE COPY ERROR
The files cannot be copied from the back-up disk to
hard disk.
One of these is displayed down.
Press any key to abort.
机器登󳇮󲣄
机器的信息文件(下列)的制失󲧺了。
将中断登󲣌按任意󳈃
Ea01623 In this mode, MOUNT DATA has been sorted automatically.
After this, please select [A5 EXECUTE].
If you want to save it, Press the [ENTER].
If you not, Press the [SPC].
If you want to cancel, Press the [ESC].
如在此状下保存,󲨉装数据将被排序。
󲣌行[A5 程序生成行]。
如要保存程序并󱮨󰋋󲣌按[ENTER]󳈃
如要󱮨󰋋󲣌按[SPACE]󳈃
按[ESC]󳈃将返回到原来的画面。
Ea01631 No machine with a head for FINE sequence is
available in the line.
Component Name
This component is defined "FINE" in Mount
Action. No machine has the alignment module
for FINE action. No machine is available
to set as "possible" in "Fine Mode"
of "Head Down Offset".
󱮔内不存在有可󲲰 FINE 作流程的󲨉的机器。
元件数据 名称
󲍒然在元件信息内将󲨉作指定 FINE,但󲢛装置却
󲳞了不 FINE 的装置。
或是在󲨉下降偏移量内没有指定可 FINE 󲨉
Ea01632 The below component is supplied from a tray changer.
Either no machine with a tray changer is
available in the line, or the tray changer
connection table is incorrect.
Component Name
下列元件󲍒是托󱎭󰀷器供󱮮的元件,但生󱮔内不存在
󱎭󰀷器的机器或是托󱎭󰀷器所󲲳接的工作台不正确。
元件数据 名称
Ea01633 No machine attached the alignment module
to recognized below component in the line.
Component Name
Check the "AlignmentModule" and "SHAPE"
in "component info."
󱮔内不存在󲢛元件的󲢛装置的󲨉
的机器。
元件数据 名称
元件信息内的󲢛装置、由元件尺寸决定的󲢛装置
不是 Head 下降偏移量内的 Head 用途󰓤󲢓置的装置。
Ea01634 The dump setting for the below component is set to
Dump Station.
下列元件的弃方法󲍒󲢓弃站,但生󱮔内不存在
弃站的机器或者不存在可到达弃站的󲨉的机器。