JX-350_EPU使用说明书.pdf - 第103页

EPU Instruction M anual C hapter 4 Creating a Production Progr am 4- 55 * JUKI 's def initi on of the component suppl y angle T able shows the def inition of t he component supply angle 0 ° and other angles. For com…

100%1 / 235
EPU Instruction Manual Chapter 4 Creating a Production Program
4-54
4.1.4.2.2 Packaging style
(1) How to enter data if you select Tapeas the Packaging style
1) Feed unit
A list of selectable feed units is displayed in the list box. Select a feed unit in this
list.
2) Feed pitch
Select the tape feeding pitch.
In the case of a 12 mm to 72 mm tape, set the pitch of
component data according to the feed pitch setting of
the tape feeder side.
Example: To make an 8 mm feed of a 12 mm tape
8 mm (4*2) Pitch = 8 mm (feed amount 4 mm x 2 times)
For the setting on the tape feeder side, refer to the "Instruction Manual for Tape
Feeder."
3) Component supply angle
Enter the angle of a component package on the tape feeder with respect to the
component placement angle, 0 degrees.
When you select Other,enter the angle in the edit field. (0° to 359.9875°)
Tape width
Pitc
Angle definition 0°
Feed angle 180°
Feed direction
EPU Instruction Manual Chapter 4 Creating a Production Program
4-55
*
JUKI's definition of the component supply angle
Table shows the definition of the component supply angle 0° and other angles.
For components without polarity, you do not have to distinguish 0° from 180° or 90°
from 270°.
Type of components
0
°
90
°
180
°
270
°
Square chip
Melf
Aluminum
electrolytic
capacitor
GaAsFET
SOT
SOP
HSOP
SOJ
QFP
QFN
QFJ(PLCC)
BQFP(PQFP)
EPU Instruction Manual Chapter 4 Creating a Production Program
4-56
TSOP-1
TSOP-2
BGA
FBGA
Network resistor
Trimmer
One-direction lead
connector
Two-direction lead
connector
Z-lead connector
J-lead socket
Gull-wing socket
Socket with bumper