EPU Instruction Manual Chapter 4 Creating a Production Program
4-47
Area check
The system checks that a component placement position is within a PWB (for a
single-plane PWB) or within a circuit (for a multi-plane PWB) at the following
timing:
1) At data entry
The system checks the component placement area when you enter or change
the placement coordinate X or Y.
If an error occurs, the system displays the following warning message.
<OK>: The system validates data you entered, and displays an asterisk
mark (*) left to the placement data number indicating the range over
error (see the figure below). When you enter a value within the
range, this mark disappears.
<Cancel>: The data you entered becomes invalid, and the system allows you
to enter data again.
2) When you switch the displayed data screen
When you switch the displayed data screen (for example, by selecting
component data), the system checks the component placement area.
If an error occurs, the system displays the following warning message.
<OK>: The system resume switching the displayed data screen.
<Cancel>: The system stops switching the displayed data screen.
* If the area check error occurs, check the data entered on the Placementdata
screen. If you do not find any problem on this screen, check each entry on the
PWBdata screen. (Check the settings of PWB layout offset,First circuit
position,” “Circuit layout offsetand each coordinate entered on theCircuit
layoutscreen especially.)
EPU Instruction Manual Chapter 4 Creating a Production Program
4-48
4.1.4 Component data
On the "Component" data screen, enter the detailed information on the "Component
name" that was entered on the "Placement" data screen.
Therefore, data will be created for the number of component names entered on the
"Placement" data screen.
4.1.4.1 Viewing the component data screen
Two types of component data screens are provided: List screen and Formscreen.
On the List screen, the system displays a list of the summary information of two or more
components.
You cannot enter any data on this screen, but you can check how you have completed
component data.
The component name items without data setting are not set are indicated in yellow.
In the component list screen, all the items are handled as sort keys and their data can be
displayed in a sorted way.
When the component names set in the component data are not used by placement data,
the items are displayed in pink.
When Component skip is set, the items are displayed in orange. For Component skip,
see "Component skip" of "4.1.4.2.5 Place condition."
Double click
EPU Instruction Manual Chapter 4 Creating a Production Program
4-49
When you select a Component name by double-clicking it on theListscreen, the
Formscreen for the selected component data appears so that you can create/edit its
component data.
The Formscreen consists of the basic setting screen, Packaging styletab, Centering
tab, Pick Conditiontab, Place Conditiontab, Inspection tab, Inspection 2tab,
Optiontab and Visiontab and displays data on only one component.
When no data is entered, the packaging style tab sheet is displayed but input items are
not displayed.
When the component packaging style of the basic section is entered, the corresponding
input items are displayed.
* JX-350 is not applicable to the vision component.
* Keyboard operation
To move the focus among the displayed items, press the TAB keyShift + key
.
To move the focus among pages, press the [PageUp] or [PageDown] key.
Tabs for switching the screen: “Form” screen and Listscreen
Data on the item you selected here appears on
the displayed area below.
Basic section