JX-350_EPU使用说明书.pdf - 第106页

EPU Instruction M anual C hapter 4 Creating a Production Progr am 4- 58 (2) How t o enter data if y ou select “ St i c k ” as the “ Packaging style ” 1) Ty p e Select a stick f eeder type. 2) Feed w ait ing tim e Set the…

100%1 / 235
EPU Instruction Manual Chapter 4 Creating a Production Program
4-57
4) Component reject to
Set the component discarding method for a case where centering results in a
recognition error or lead floating inspection results in an error.
Select the component discarding method from the drop-down list in the combo
box.
The discarding methods displayed in the list vary depending on your selection of
the Tape Width.
Menu items displayed
in the drop-down list
Description
Trash box This item can be selected for every component.
Components with 15 mm or less in length/width/height are
discarded at the small-sized component discarding position.
Components other than small-sized and large-
sized components
are discarded at the medium-sized component discarding
position.
Tray return When Tray is selected for the packaging style, this item can be
selected.
Protect You can select this item for all component types.
5) Feed Speed
Set a pitch feed speed of the electric feeder.
To change the feed seed, check on the [Yes] check box in the “Setting” area and
select “Fast”, “Medium”, or “Slow” from the drop down list.
If components roll in the cavity as they are fed, this symptom can be controlled by
changing the feed speed.
EPU Instruction Manual Chapter 4 Creating a Production Program
4-58
(2) How to enter data if you select Stickas the Packaging style
1) Type
Select a stick feeder type.
2) Feed waiting time
Set the ratio of the actual waiting time to the waiting time (that is, waiting time set
per feeder type) the system has to wait until it system can pick up the next
component after picking up the current component on a percentage basis.
The initial value is 100 %.
3) Supply angle
Enter the angle of the component package on the stick feeder with respect to the
component placement angle, 0 degrees.
For details, see "(1) Tape input method * JUKI component feed angle definition."
When you select Other,enter the angle in the edit field. (0º to 359.9875º)
4) Component reject to
Set the component discarding method for a case where centering results in a
recognition error or lead floating inspection results in an error.
For details, see "(1) Tape input method, Component discarding."
Angle definition 0°
Feed angle 270°
Feed direction
EPU Instruction Manual Chapter 4 Creating a Production Program
4-59
(3) Tray input method
1) Pilot Position
Enter the distance from the tray outside to the center position (X, Y) of the first
tray component.
2) Pitch between components
Enter the pitch between components (Pitch X, Pitch Y).
3) No. of columns/rows
Enter the number of components (Xn, Yn) in the lateral direction and the
longitudinal direction.
After the pickup data supply position is determined, the coordinates of 3 positions
of the tray are displayed in the pickup data. (X
1
, Y
1
to X
3
, Y
3
)
First component position X
First component
position Y
First
component
Pitch X
Pitch Y
X
2
,Y
2
X
1
Y
1
X
3
Y
3