JX-350_EPU使用说明书.pdf - 第139页
EPU Instruction M anual C hapter 4 Creating a Production Progr am 4- 91 4.1.6 Checking t he statu s of dat a completi on Now w e ar e checking how data has been completed. Incom plete data does not allow optimization. W …
EPU Instruction Manual Chapter 4 Creating a Production Program
4-90
(7) Status (Used)
Specify whether or not to use this feeder unit when production.
“Used” is selected as the initial setting.
(The “Yes” radio button is selected on the “Component List” screen. To change this
setting, press the [F2] key or click it with the right button of the mouse.)
If there are two or more feeder units, specify the unit that is actually used for
production with this machine.
A feeder unit whose “Status” is “Not used (No)” cannot be used as an alternate feeder
even though there are two or more feeder units.
(8) Remain
Specify the component remaining. It is necessary to specify the tray components,
but they can not specify the feeder components.

EPU Instruction Manual Chapter 4 Creating a Production Program
4-91
4.1.6 Checking the status of data completion
Now we are checking how data has been completed. Incomplete data does not allow
optimization.
When you select the [Data]/[Data completion status] commands from the menu bar, the
following screen appears.
When the total number of records is equal to the number of completed records, data has
been completed, and an asterisk "*" is inserted between the parentheses "( )" of the
"Complete" field. For the "Pick data" or any other data whose "No. of Records" field is
null (0), that item is considered to have been completed although an asterisk "*" is not
displayed.
If you find any incomplete item, make it complete.

EPU Instruction Manual Chapter 4 Creating a Production Program
4-92
4.1.7 Line coherence check
This section describes the check of the prepared program for inconsistency with the
settings in the "EPU setup" menu or for inconsistency in the program itself.
When the coherence check is finished successfully, we can advance to optimization.
If any error is detected, the details of error will be displayed. Correct the program taking
into consideration the displayed errors or setting on the "Machine Setup" menu.
(1) Exciting the coherence check
When you select the [Data (D)]/[Line coherence check (L)] commands on the menu
bar, the system executes the coherence check.
(2) Reporting the coherence check
After the system finishes the coherence check, one of the following messages
appears on the screen.
① No error was found.
② Error(s) was(were) detected.
When you click the <OK> button at this point, the inquiry dialog box appears on the
screen that asks you whether to display the detailed information on the error(s).
Select <OK>, and the error information will be displayed.
(3) Information on the error
Data type Data creation number Detailed information on the error
・ Example of detailed information on error shown above
Since the nozzle specified for the first component of the Component data is
not set on the “EPU setup” screen, you cannot use it.