DIAGNOSTICS CAMERA AXES Chapter Issue 4, Aug 14 Technical Reference Manual 39.17 Inspection Lighting Selecting this diagnostic function alter nately switches the insp ection lighting on and off, continuously displaying t…

100%1 / 310
DIAGNOSTICS
CAMERA AXES
39.16 Technical Reference Manual Chapter Issue 4, Aug 14
Home Camera X
Axis
Selecting this diagnostic function drives the camera X carriage to its home
position, as determined by its home sensor.
Home Camera Y
Axis
Selecting this diagnostic function drives the camera Y carriage to its home
position, as determined by its home sensor.
Camera Axis to
Fiducial 1 Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the fiducial 1 X and Y coord parameters.
Camera Axis to
Fiducial 2 Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the fiducial 2 X and Y coord parameters.
Camera Axis to
Fiducial 3 Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the fiducial 3 X and Y coord parameters.
Drive to Board
Stop Position
Selecting this diagnostic function drives both X and Y carriages to the position
of the board stop for the current product.
Restore Default
Reference Position
Selecting this diagnostic function restores the reference position stored as a
default in software.
Drive to Reference
Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the camera X and Y reference parameters.
Set Reference
Position
Selecting this diagnostic function alters the printer configuration file after the
camera has been positioned, so that it is viewing the reference mark on the front
rail. On selection the menu bar displays Confirm, pressing this key alters the
printer configuration file. This is used in conjunction with move camera X and
Y axes. Refer to the Technical Reference Manual Camera and Vision System
Chapter for the camera reference position procedure.
Move Camera X
Axis Using Jog
Buttons
Selecting this diagnostic function moves the camera X axis using the jog
buttons. The right jog button drives the camera to the left at slow speed and the
left jog button drives the camera to the right, stopping immediately the button is
released. This is a physical movement of the camera, not as displayed on the
monitor.
Move Camera Y
Axis Using Jog
Buttons
Selecting this diagnostic function moves the camera Y axis using the jog
buttons. The right jog button drives the camera to the rear at slow speed and
the left jog button drives the camera forward, stopping immediately the button
is released. This is a physical movement of the camera, not as displayed on
the monitor.
Initialise Vision
System
Selecting this diagnostic function initialises the frame grabber board and it
displays a live image on the vision monitor and a superimposed box graphic.
Fiducial Lighting Selecting this diagnostic function alternately switches the fiducial lighting on and
off, continuously displaying the current status.
DIAGNOSTICS
CAMERA AXES
Chapter Issue 4, Aug 14 Technical Reference Manual 39.17
Inspection
Lighting
Selecting this diagnostic function alternately switches the inspection lighting on
and off, continuously displaying the current status.
Cycle Camera
System
Selecting this diagnostic function starts a continuous cycle of driving the camera
X and Y carriages to each of the following positions in sequence, dwelling for 2
seconds at each point, locating the fiducial at each fiducial position, displaying
the returned location and repeating the cycle. The cycle is as follows:
1. Home
2. Fiducial 1
3. Fiducial 2
If the data logging is enabled the fiducial coordinates are appended to:
D:\Program Files\DEK\MachineControl\Printer\Camera.Dat file.
This continuous cycle is terminated by selecting the stop key or when the set
cycle count has been reached.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count. The cycle count may be preset 5 -
9995 cycles (default 50) by selecting Adjust.
DIAGNOSTICS
RAIL SYSTEM
39.18 Technical Reference Manual Chapter Issue 4, Aug 14
RAIL SYSTEM Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of diagnostic
parameters.
Incr./Decr. changes the value of the selected diagnostic parameter.
Exit returns operation to the rail system diagnostics page.
NOTE
These parameters are used in diagnostics only and have no affect on the
product board file.
Home Rail Width Selecting this diagnostic function drives the moving rail to its home position as
determined by its home sensor.
Drive Rail to Board
Width
Selecting this diagnostic function drives the moving rail to the width set by the
board width parameter.
Board Stop In Position
Board at Stop
OFF
OFF
ON
.. more
Home Rail Width
Drive Rail To Board Width
Set Rail Board Width Calibration
Drive Rail Width Using Two Button Control
Drive Belts Using Two Button Control
Belt Speed Calibration
Toggle Board Clamp
Toggle Board Stop
Toggle Downline Board stop
Cycle Board On Belts
Cycle Board Clamp
Cycle Rails
Rail System Diagnostics
OFF
OFF
Run
Diagnost
NextAdjust
Previous
Exit
Rail System Test Parameters
BOARD WIDTH
CYCLE COUNT
250.0
50
mm
Cycles
Next Incr. Decr.
Previous
Exit