DIAGNOSTICS SYSTEM Chapter Issue 4, Aug 14 Technical Reference Manual 39.7 Node 9 Group 0 Node 10 Group 0 Display All Analogue Inputs Selecting this diagnostic func tion opens the following window: The following icons ar…

100%1 / 310
DIAGNOSTICS
SYSTEM
39.6 Technical Reference Manual Chapter Issue 4, Aug 14
Node 4 Group 2
Node 6 Group 0
Node 7 Group 0
Node 8 Group 0
Node 4 Group 2
Point Description
---------------------
---------
-------
Bit No
Sense
-----------
------
Direction
State
Solvent Pinch Valve
Cleaner Paper Feed
Cleaner Vacuum
Oscillating Motor
Not Used
Not Used
Not Used
1
2
3
4
5
6
7
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Output
Output
Output
Output
Output
Output
Output
DIG OUT 0
DIG OUT 4
DIG OUT 1
Signal
DIG OUT 5
DIG OUT 6
DIG OUT 2
DIG OUT 3
DIG OUT 7
Cleaner Home Clamp
0
Negative
Output
ON
ON
ON
ON
ON
ON
ON
ON
Node 6 Group 0
Point Description
---------------------
---------
-------
Bit No
Sense
-----------
------
Direction
State
DIG IN 0
Signal
Table at Home
0
Positive
Input
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Node 7 Group 0
Point Description
---------------------
---------
-------
Bit No
Sense
-----------
------
Direction
State
DIG IN 2
Signal
Print Carriage Home
2
Positive
Input
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Node 8 Group 0
Point Description
---------------------
---------
-------
Bit No
Sense
-----------
------
Direction
State
DIG IN 2
Signal
Camera X Home
2
Positive
Input
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
DIAGNOSTICS
SYSTEM
Chapter Issue 4, Aug 14 Technical Reference Manual 39.7
Node 9 Group 0
Node 10 Group 0
Display All
Analogue Inputs
Selecting this diagnostic function opens the following window:
The following icons are displayed:
Exit returns operation to the system diagnostics page.
Node 9 Group 0
Point Description
---------------------
---------
-------
Bit No
Sense
-----------
------
Direction
State
DIG IN 2
Signal
Camera Y Home
2
Positive
Input
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Node 10 Group 0
Point Description
---------------------
---------
-------
Bit No
Sense
-----------
------
Direction
State
DIG IN 0
Signal
Paste Carriage Home
0
Positive
Input
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Analogue I/O Values
Description
--------------
----------------
Integer Value
--------------------
Converted Value
Pressure Sensor
Temperature
Relative Humidity
Solvent Tank Level
ProFlow Medium Level
2327
3644
2985
345
857
8.51 kg
24.573 C
42.386 %
64 %
12 %
o
Exit
DIAGNOSTICS
SYSTEM
39.8 Technical Reference Manual Chapter Issue 4, Aug 14
Toggle Beacon Selecting any one of the three toggle beacon diagnostic functions, alternately
switches them between on and off.
Toggle Lid Bolt Selecting this function alternately extends and retracts the lid bolt.
Data Logging Selecting this diagnostic function alternately enables and disables data logging
during diagnostic operations.
Terminate Control
Program
Selecting this diagnostic function terminates the control program and returns to
Windows.