88192277-01-19 - Micron Technical Reference V9 Volume 4.pdf - 第109页
DIAGNOSTICS SCREEN ALIGNMENT Chapter Issue 4, Aug 14 Technical Reference Manual 39.23 SCREEN ALIGNMENT Selecting this diagnostics modul e opens the following window: The following icons are displayed: Next/Previous moves…

DIAGNOSTICS
PASTE DISPENSE SYSTEM
39.22 Technical Reference Manual Chapter Issue 4, Aug 14
Cartridge in Up
Position
This diagnostic function continuously displays the status of the cartridge home
(up) sensor.

DIAGNOSTICS
SCREEN ALIGNMENT
Chapter Issue 4, Aug 14 Technical Reference Manual 39.23
SCREEN ALIGNMENT
Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The following icons are displayed:
Next/Previous have no function in this application.
.
Incr./Decr. changes the value of the selected diagnostic parameter.
Exit returns operation to the stencil alignment diagnostics page.
Home Actuators Selecting this diagnostic function drives the X forward, X Rear and Y Axis
actuators simultaneously to their home positions, as determined by their home
sensors.
Drive X Forward
Motor Using Jog
Buttons
Selecting this diagnostic function drives the X forward actuator using the jog
buttons. The right Jog button drives the X forward actuator right at slow speed
and the left Jog button drives it left, stopping immediately the button is released.
Drive X Rear Motor
Using Jog Buttons
Selecting this diagnostic function drives the X rear actuator using the jog
buttons. The right jog button drives the X rear actuator right at slow speed and
the left jog button drives it left, stopping immediately the button is released.
Cycle Count
Done :-
0, To go :-
50
ON
Home Actuators
Drive X Forward Motor Using Jog Buttons
Drive X Rear Motor Using Jog Buttons
Drive Y Motor Using Jog Buttons
Toggle Chase Clamp
Cycle Alignment System
Screen Alignment Diagnostics
Run
Diagnost
NextAdjust
Previous
Exit
Actuator Cycle Test Parameters
CYCLE COUNT
50.0
Cycles
Next Incr. Decr.
Previous
Exit

DIAGNOSTICS
SCREEN ALIGNMENT
39.24 Technical Reference Manual Chapter Issue 4, Aug 14
Drive Y Motor
Using Jog Buttons
Selecting this diagnostic function drives the Y actuator using the jog buttons.
The right jog button drives the Y actuator forward at slow speed and the left jog
button drives it to the rear, stopping immediately the button is released.
Toggle Chase
Clamp
Selecting this diagnostic function alternately energizes and de-energizes the
chase clamp solenoid, displaying On when the clamps are energized and Off
when the clamps are de-energized.
Cycle Alignment
System
Selecting this diagnostic function starts a continuous cycle of driving the stencil
actuators to each of the positions in the table below in sequence, dwelling for 2
seconds at each point and continuing the cycle.
The positions are given as XF, XR and Y in mm from the home position and are
as follows:
If data logging is enabled, every time the stencil returns to 0,0,0, locate a stencil
fiducial and its coordinates are appended to:
D:\Program Files\DEK\MachineControl\Printer\Screen.Dat file.
This continuous cycling is terminated by selecting the stop key or when the set
cycle count has been reached.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count. The cycle count may be preset 5 -
9995 cycles (default 50) by selecting Adjust.
10, 0, 0.
2 +20, +10, +10.
30, 0, 0.
4 -20, -10, -10.
50, 0, 0.
6 +10, +20, -10.
70, 0, 0.
8 -10, -20, +10.