DIAGNOSTI CS PASTE DISPENSE SYSTEM 39.22 Technical Reference Manual Chapter Issue 4, Aug 14 Cartridge in Up Position This diagnostic function continuously disp lays the status of the cartridge home (up) sensor .

100%1 / 310
DIAGNOSTICS
PASTE DISPENSE SYSTEM
Chapter Issue 4, Aug 14 Technical Reference Manual 39.21
PASTE DISPENSE SYSTEM
Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Carriage Home Selecting this diagnostic function drives the paste dispense carriage left to its
home position, as determined by its home sensor.
Drive Carriage to
Start Position
Selecting this diagnostic function drives the paste dispense carriage to the
position set by the paste start parameter.
Drive Carriage to
End Position
Selecting this diagnostic function drives the paste dispense carriage to the
position set by the paste stop parameter.
Drive Cartridge
Down
Selecting this diagnostic function drives the cartridge tilt motor down until the
cartridge away (down) sensor is detected.
Drive Cartridge Up Selecting this diagnostic function drives the cartridge tilt motor up until the
cartridge home (up) sensor is detected.
Toggle Paste
Dispense
Selecting this diagnostic function alternately applies and removes the air pres-
sure to the paste dispense cartridge, displaying On when air pressure is applied
and Off when air pressure is removed.
Paste Cartridge
Empty
This diagnostic function continuously displays the status of the cartridge empty
sensor.
Cartridge in Down
Position
This diagnostic function continuously displays the status of the cartridge away
(down) sensor.
Paste Cartridge Empty
Cartridge in Down Position
Cartridge in Up Position
OFF
OFF
Carriage Home
Drive Carriage To Start Position
Drive Carriage To End Position
Drive Cartridge Down
Drive Cartridge Up
Toggle Paste Dispense
Paste Dispense System Diagnostics
ON
ON
Run
Diagnost
Next
Previous
Exit
DIAGNOSTICS
PASTE DISPENSE SYSTEM
39.22 Technical Reference Manual Chapter Issue 4, Aug 14
Cartridge in Up
Position
This diagnostic function continuously displays the status of the cartridge home
(up) sensor.
DIAGNOSTICS
SCREEN ALIGNMENT
Chapter Issue 4, Aug 14 Technical Reference Manual 39.23
SCREEN ALIGNMENT
Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The following icons are displayed:
Next/Previous have no function in this application.
.
Incr./Decr. changes the value of the selected diagnostic parameter.
Exit returns operation to the stencil alignment diagnostics page.
Home Actuators Selecting this diagnostic function drives the X forward, X Rear and Y Axis
actuators simultaneously to their home positions, as determined by their home
sensors.
Drive X Forward
Motor Using Jog
Buttons
Selecting this diagnostic function drives the X forward actuator using the jog
buttons. The right Jog button drives the X forward actuator right at slow speed
and the left Jog button drives it left, stopping immediately the button is released.
Drive X Rear Motor
Using Jog Buttons
Selecting this diagnostic function drives the X rear actuator using the jog
buttons. The right jog button drives the X rear actuator right at slow speed and
the left jog button drives it left, stopping immediately the button is released.
Cycle Count
Done :-
0, To go :-
50
ON
Home Actuators
Drive X Forward Motor Using Jog Buttons
Drive X Rear Motor Using Jog Buttons
Drive Y Motor Using Jog Buttons
Toggle Chase Clamp
Cycle Alignment System
Screen Alignment Diagnostics
Run
Diagnost
NextAdjust
Previous
Exit
Actuator Cycle Test Parameters
CYCLE COUNT
50.0
Cycles
Next Incr. Decr.
Previous
Exit