38.40 Technical Reference Manual Chapter Issue 4, Nov 19 STINGER CALIBRATIONS 3. Select Stinger Dispenser . 4. Select Create Site . Using the options on the right hand side set th e Site X and Y coordinates for the site,…

STINGER
CALIBRATIONS
Chapter Issue 4, Nov 19 Technical Reference Manual 38.39
Remove the product from the printer and measure the offsets. The offset
quadrants are shown below. Amend the X and Y calibrated offset parameters.
9. Select Stinger Calibrated Offset Y to set the parameter initially to 0 (zero
offset).
10. Select Back.
11. Select Back.
12. Select Back.
13. Select Save.
14. Select Back.
15. Select Setup Product.
16. Select Options.
17. Select Stinger Dispenser.
18. Select Load Board. Choose the preferred load board method, auto or
manual.
19. Select Dispense Sweep.
The system dispenses at the programmed site. Any offset between the pro-
grammed site and the material is the equivalent offset in the Y plane. Program
the parameter to compensate for this; it can be any value between
-5mm and +5mm.
Stinger Laser
Offsets X and Y
This parameter sets a factor to compensate for any offsets of the nozzle to laser,
in the X and Y planes, at the point where the laser actually measures. This can
be any value between -5mm and +5mm. As with the calibrated offsets, a deposit
point is marked on the calibration board. The offset is set to zero and a deposit
is made; the difference between the deposit centre and the laser centre is the
amount of compensation to be set.
Set the measurement option to measure only (on a single site).
NOTE
If more than one site is to be utilised and an image is available, select Load
Image to load a GERBER image file.
1. Select Setup.
2. Select Options.
X Offset +
X Offset +
Y Offset - Y Offset -
X Offset -
X Offset -
Y Offset + Y Offset +

38.40 Technical Reference Manual Chapter Issue 4, Nov 19
STINGER
CALIBRATIONS
3. Select Stinger Dispenser.
4. Select Create Site. Using the options on the right hand side set the Site X
and Y coordinates for the site, Site Name, Feed (number of steps that
equate to the volume of adhesive to be dispensed), Reverse (the number of
steps to lift the dispenser after dispensing has taken place), Stinger Dis-
pense Gap (sets the gap between the dispenser nozzle and the board
surface during dispensing) and Dispense Mode (the type of dispense to be
used).
5. Select Accept.
6. Select Setup Sites.
7. Select Adjust Site, make a note of the current Dispense Mode and set the
dispense mode to Measure Only.
8. Select Accept.
9. Select Confirm.
10. Select Back three times.
11. Select Save.
12. Select Back.
13. Select Open Cover Commands. Open the printhead cover.
14. Cover the stencil sensor; close the printhead cover and press the System
button.
15. Select Back.
16. Select Load Screen. The stencil clamps actuate.
17. Select Setup Product.
18. Select the following: Fiducials, Global Settings, Alignment Mode and
change to None Vision.
19. Select Accept,
20. Select Back three times.
21. Select Setup Product.
22. Select Options.
23. Select Stinger Dispenser.
24. Select Load Board. Choose the preferred load board method, auto or
manual.

STINGER
CALIBRATIONS
Chapter Issue 4, Nov 19 Technical Reference Manual 38.41
25. Select Dispense Sweep.
Measure the Laser Offset X and Y between the dispensed dot and the laser
beam position. The object must have the laser beam shining on the dot centre.
Edit the Laser X and Y offsets as required.
26. Select Back.
27. Select Adjust Site, set the dispense mode to its original state.
28. Select Back.
29. Select the following: Fiducials, Global Settings, Alignment Mode and
change to 2 Fiducial.
30. Select Accept.
31. Select Back.
32. Select Save.
33. Select Back.
34. Select Auto Board.
Purge Station
Location
This parameter sets the location at the front of the rising table where the purge
station is placed. At the start or end of a production run, the user may request
a purge. Purging ensures that the flow of adhesive is continuous and homoge-
neous. The purge station contains a pot that collects the purged adhesive; the
purge station can be located on the front left or front right corner of the rising
table.
Laser Centre
Nozzle Centre
Top View
Front View
X Offset