88192277-01-19 - Micron Technical Reference V9 Volume 4.pdf - 第112页
DIAGNOSTI CS SCREEN CLEANER 39.26 Technical Reference Manual Chapter Issue 4, Aug 14 SCREEN CLEANER Selecting this diagnostics modul e opens the following window: The following icons are displayed: Next/Previous moves th…

DIAGNOSTICS
SCREEN CHANGE
Chapter Issue 4, Aug 14 Technical Reference Manual 39.25
SCREEN CHANGE Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous have no function in this application.
Run Diagnost activates the toggle stencil clamps diagnostic function.
Exit returns operation to the module diagnostics page.
Toggle Screen
Clamps
Selecting this diagnostic function alternately energizes and de-energizes the
stencil clamps, displaying On when energized and Off when de-energized.
Screen Sensor This diagnostic function continuously displays the status of the stencil sensor.
Screen Change Diagnostics
Toggle Screen Clamps
Toggle Screen Stop
Load Screen
Centre Screen Sensor
OFF
ON
OFF
Run
Diagnost
Next
Previous
Exit

DIAGNOSTICS
SCREEN CLEANER
39.26 Technical Reference Manual Chapter Issue 4, Aug 14
SCREEN CLEANER
Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The following icons are displayed:
Incr./Decr. changes the value of the cycle count.
Exit returns operation to the screen cleaner diagnostics page.
Toggle Dry Wipe
Blade
Selecting this diagnostic function raises and lowers the cleaner body assembly,
displaying On when the cleaner body assembly is raised and Off when the
cleaner body assembly is lowered.
Toggle Solvent
Pump
Selecting this diagnostic function alternately switches the solvent pump on and
off, displaying its current status.
Toggle Paper Feed Selecting this diagnostic function alternately switches the paper feed motor on
and off, displaying its current status.
OFF
Screen Cleaner Diagnostics
ON
OFF
Toggle Dry Wipe Blade
Toggle Solvent Pump
Toggle Paper Feed
Toggle Vacuum
Toggle Screen Cleaner Home Clamp
Cycle Clean Blade
Toggle Cleaner Camera
Clamp
Toggle Oscillate
OFF
OFF
OFF
ON
ON
OFF
Cleaner Paper Low/Advance
Cleaner Solvent Low
Cleaner Attached
Cycle Count
Done :-
0,To go :-
50
ON
ON
. . . more
Run
Diagnost
NextAdjust
Previous
Exit
Cleaner Cycle Parameters
CYCLE COUNT
50.0
Cycles
Incr. Decr.
Exit

DIAGNOSTICS
SCREEN CLEANER
Chapter Issue 4, Aug 14 Technical Reference Manual 39.27
Toggle Vacuum Selecting this diagnostic function alternately switches the vacuum pump on and
off, displaying its current status.
Toggle Screen
Cleaner Home
Clamp
Selecting this diagnostic function alternately energizes and de-energizes the
screen cleaner home clamp electromagnet, displaying its status.
Cycle Clean Blade Selecting this diagnostic function continuously raises and lowers the cleaner
body assembly for the number of cycles specified in the cycle count.
Toggle Cleaner
Camera Clamp
Selecting this diagnostic function alternately energizes and de-energizes the
cleaner camera clamp electromagnet, displaying its status.
Toggle Oscillate Selecting this diagnostic function alternately switches the oscillating motor on
and off, displaying its current status.
Cleaner Paper
Low/Advance
This diagnostic function continuously displays the status of the cleaner paper
low/advance sensor.
Cleaner Solvent
Low
This diagnostic function continuously displays the status of the cleaner solvent
low sensor.
Cleaner Attached This diagnostic function continuously displays the status of the cleaner dropped
sensor.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count. The cycle count may be preset 5 -
9995 cycles (default 50) by selecting Adjust.