88192277-01-19 - Micron Technical Reference V9 Volume 4.pdf - 第205页

TRANSPORTATION - MAJOR RELOCATION MACHINE SUPPLIES AND EN VIRONMENTAL CONDITIONS Chapter Issue 5, Nov 19 Technical Reference Manual 42.39 And as described in the IPC Standard J-STD-001G-Requirements fo r Soldered Electri…

100%1 / 310
TRANSPORTATION - MAJOR RELOCATION
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
42.38 Technical Reference Manual Chapter Issue 5, Nov 19
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
Operating
Conditions
The printer must only be operated in the following operating envelope:
• Indoors only
• Unsuitable for use in wet locations
• Temperature = 5 to 40°C (40 to 105°F)
• Humidity = Maximum 80% Relative Humidity (non condensing)
• Altitude = Maximum 2,000 metres (6,500 feet)
• Pollution must comply to Degree 2
ASM KVArecommends a power supply capacity of 2.4 or greater.
Electrical
ASM requires additional machine supply protection with the fitment of an external double pole
circuit breaker conforming to national, federal or local legislation. recommends that the
external circuit breaker is fitted near the printer and within easy reach of the operator. Use
the following table to ensure the recommended circuit breaker is used:
ASM
DEK
The machine operates on 115V to 230V ±10% 50/60Hz single phase ac mains.
Pneumatic Supply
The machine requires a pneumatic supply of clean, non lubricated air which should maintain a
minimum pressure of 5 Bar and a maximum of 8 Bar. The printer requires 5 litres/minute for
general use and a maximum of 226 litres/minute at 6 Bar.
The air should be to ISO 8573.1 standard, quality class 2.3.3
NOTE
An over current circuit breaker protects the machine's internal wiring and components from
overheating or catching fire during fault conditions. Under no circumstances must a circuit
breaker of value greater than 20 Amps be fitted.
Transient overvoltages must not exceed those defined in Cat 2 of 60364-4-443.IEC
Voltage fluctuations must not exceed 10% of nominal voltage.
115 Volts
115 Volts
115 Volts
230 Volts
230 Volts
With VF25 Internal
Vacuum Unit
With VF30/35 Internal
Vacuum Unit
Without Internal
Vacuum Unit
230 Volts
Machine Current Consumption (Approx)
Value of Wall Mounted Circuit Breaker
12 Amps
15 Amps
16 Amps
16 Amps
6 Amps
10 Amps
6 Amps
8 Amps
10 Amps
10 Amps
3 Amps
6 Amps
TRANSPORTATION - MAJOR RELOCATION
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
Chapter Issue 5, Nov 19 Technical Reference Manual 42.39
And as described in the IPC Standard J-STD-001G-Requirements for Soldered
Electrical and Electronic Assemblies Section 4 with respect to the following:
• Facilities - Cleanliness and ambient environments in all work areas be
maintained at levels that prevent contamination or deterioration of tools,
materials, and surfaces to be soldered or conformally coated. Eating,
drinking, smoking, including use of e-cigarettes, and/or use of tobacco
products be prohibited in the work area.
• Environmental Controls - The soldering facility (controlled work area) be
enclosed, temperature and humidity controlled, and maintained at a posi-
tive pressure.
• Controlled Work Area (CWA) For the purpose of this statement, a Con-
trolled Work Area (CWA) is defined as an enclosed assembly / processing
area maintained to a high degree of shop cleanliness, environmental
control, and foreign object debris (FOD) mitigation, either by process or
procedure, to limit the entry of contamination.
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
This equipment should be installed in accordance with the Installation Manual.
ASM absolves itself of all responsibility if the machine is not used within its
operating envelope or for its intended purpose.
TRANSPORTATION - MAJOR RELOCATION
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
42.40 Technical Reference Manual Chapter Issue 5, Nov 19
Machine Footprints
Figure 42-8 Type 1 Covers
R0630.
Max dimension from
pivot point
360
1150
Transfer Height 960
980 max)
(840 min to
Side View (Right)
1345
( min to 13 2 max)1102 6
1106
(1352 min to 1492 max)
141
Front View
1913
(1 min to 1 max)834 974
1471.5
Plan View
606
Front of
board
1758
1334
Weight
Boxed - 8 kg, Unboxed - 6 kg10 60
(Dependent upon configured options
selected with the machine)
Note
All dimensions
in millimetres
Board transfer
height 8
- 980 mm40
Screen load height 925 - 1065
mm