DIAGNOSTI CS PASS THROUGH RAILS 39.36 Technical Reference Manual Chapter Issue 4, Aug 14

100%1 / 310
DIAGNOSTICS
PASS THROUGH RAILS
Chapter Issue 4, Aug 14 Technical Reference Manual 39.35
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count. The cycle count may be preset 5 -
9995 cycles (default 50) by selecting Adjust.
DIAGNOSTICS
PASS THROUGH RAILS
39.36 Technical Reference Manual Chapter Issue 4, Aug 14
SENSORS
INTRODUCTION
Chapter Issue 6, May 19 Technical Reference Manual 40.1
CHAPTER 40 SENSORS
INTRODUCTION This chapter gives details of the various sensors used in the printer. All sensors
used on the printer fall within three categories, these are:
• Solid State Switch Sensors
• Conventional Switch Sensors
• Analogue Sensors
Solid State
Switches
The printer uses the following types of solid state sensor switches:
• Hall Effect Sensors
• Opto Sensors
• Ultrasonic Sensor
• Capacitive Proximity Sensor
In all cases to initiate a logic 1 (on state) at the input, the sensor must connect
the signal input to 0V. This may not, however, translate to a positive condition
after software processing.
Figure 40-1 Typical Solid State Schematic
Testing Solid state sensors can only be tested in circuit as they require a logic supply
voltage and a pull up resistor on the sensor output.
1. Check for the 12V logic supply to the sensor.
2. Activate the sensor according to type and measure the voltage at the output
terminal with respect to 0V. The sensor output signal should change
between approximately 0V and 12V (see individual sensor descriptions for
more details).
Digital Input
+V
12V
Opto-isolator
1K8
0V
Signal I/P
Control
Circuit
Solid State