TRANSPORTATION - POWER UP
PRE POWER UP CHECKS
43.6 Technical Reference Manual Chapter Issue 3, Nov 19
Pneumatic Supply The machine requires a pneumatic supply of clean, non lubricated air which
should maintain a minimum pressure 5 Bar and a maximum of 8 Bar.
The air should be to ISO 8573.1 standard, quality class 2.3.3, where:
• 2 dirt = 1 micron
• 3 water = -20°C pressure dewpoint
• 3 oil = 1mg/m3
Electrical Supply The factory mains supply for the machine is routed through the front panel
mounted mains isolator switch and on to the M37 power supply enclosure where
various low voltages are distributed throughout the machine.
Figure 43-3 Mains Electrical Supply
The machine operates on 115V to 230V ± 10% at 50/60Hz single phase ac
mains.
ASM recommends a power supply capacity of 2.4KVA or greater.
ASM requires additional machine supply protection with the fitment of an
external double pole circuit breaker conforming to national, federal or local
legislation. Use the following table to ensure the recommended circuit breaker
is used:
NOTE
An over current circuit breaker protects the machines internal wiring and
components from overheating or catching fire during fault conditions. Under no
circumstances must a circuit breaker of value greater than 20 Amps be fitted.
115 Volts 230 Volts
Wall Mounted Type C Circuit Breaker (without Vacuum Unit) 10 Amp 6 Amp
Wall Mounted Type C Circuit Breaker (with VF25 Vacuum Unit) 16 Amp 10 Amp
Wall Mounted Type C Circuit Breaker (with VF30/355 Vacuum Unit) 16 Amp 10 Amp
To Factory Mains Supply
Mains Isolator
Switch
M37 Power Supply Enclosure

TRANSPORTATION - POWER UP
PRE POWER UP CHECKS
Chapter Issue 3, Nov 19 Technical Reference Manual 43.7
Preparations 1. Ensure machine mains isolator is OFF.
2. Check and verify that the mains electrical supply is single phase 115V to
230V ±10% at 50/60Hz ac.
3. Check that all circuit breakers are in the ON position.
4. Ensure that all access covers and removable panels are closed and are in
place.
5. Ensure that the E Stop button is in the fully out position. To check this, push
the E Stop button until it latches. Turn the button clockwise to release it.

TRANSPORTATION - POWER UP
MACHINE POWER UP SEQUENCE
43.8 Technical Reference Manual Chapter Issue 3, Nov 19
MACHINE POWER UP SEQUENCE
Apply Systems
Power
1. Connect the pneumatic supply to the connection on the rear, bottom left of
the machine, External Services section of this chapter refers.
2. Connect the mains supply to the machine.
3. Turn the Mains Isolation Switch ON.
4. Select Diagnostics.
5. Ensure that System is highlighted and select Select Module.
6. Select the Previous button once to highlight Terminate Control Program.
7. Select Run Diagnost.
Date and Time In order for the machine PC to log events correctly, the system time, date and
correct time zone must be set.
Windows 7 1. Select the clock displayed at the right hand side of the Windows taskbar.
The following window is displayed:
2. Select Change date and time settings....