TRANSPORTATION - MAJOR RELOCATION
MACHINE ASSEMBLY
Chapter Issue 5, Nov 19 Technical Reference Manual 42.101
upwards).
16. Remove the sealing plug from the transfer head.
17. Remove the base cover from the transfer head.
Levelling the
Transfer Head
For an even application of print medium, during both the forward and rearward
print-strokes, obtain equal pressure on the tips of the wiper blades by levelling
the transfer head against the stencil when under system pressure. To adjust the
level of the transfer head, carry out the following on the ProFlow ATx mount:
1. Loosen the two transfer head pin mount lock screws, using a 3mm Allen key.
2. Evenly adjust the two transfer head levelling screws, using a 2mm Allen key.
Turning the levelling screws clockwise lowers the front of the transfer head.
Turning the levelling screws counter-clockwise raises the front of the trans-
fer head.
3. Tighten the two transfer head pin mount lock screws, using a 3mm Allen key.
4. Perform a print operation.
5. Inspect the print medium application; if further levelling is required, repeat
the procedure.
Transfer Head Vertical Pin Mount on ProFlow ATx Mount
Transfer Head
Levelling Screws
Pin Mount Lock Screws
View on Transfer Head Left Hand End (Through ProFlow Mount)
Transfer Head’s
Point of Rotation
Levelling Screws Clockwise
Levelling Screws Counter-clockwise

TRANSPORTATION - MAJOR RELOCATION
MACHINE ASSEMBLY
42.102 Technical Reference Manual Chapter Issue 5, Nov 19
Paste Dispenser
Fit Print Medium Cartridge
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
WARNING
MOVING PARTS. MOVING PARTS ARE PRESENT IN THE VICINITY OF THIS
WARNING LABEL, THESE PARTS HAVE THE POTENTIAL TO CAUSE INJURY.
NOTE
The following procedure assumes that an empty cartridge is fitted; if this is not
the case, open the lever arm (Step 4) and begin the procedure at Step 9 - “Fit
the new print medium cartridge to the filler tube assembly”.
To fit a new print medium cartridge to the ProFlow ATx system, carry out the
following:
1. Open the machine cover.
View on Front
Print Medium
Level Sensor
Print Medium
Cartridge Holder
Print Medium
Filler Tube
Assembly
Print Medium Pneumatic
Delivery Mechanism

TRANSPORTATION - MAJOR RELOCATION
MACHINE ASSEMBLY
Chapter Issue 5, Nov 19 Technical Reference Manual 42.103
2. Pull the lever arm towards the left side of the machine.
3. Rotate the print medium cartridge anti-clockwise 90°.
NOTE
During removal of the print medium cartridge, the filler tube assembly
remains attached to the nozzle of the cartridge. Do not remove the print
medium cartridge from the cartridge holder assembly until the cartridge has
been fully rotated 90° and the filler tube adaptor has reached the unlocked
position.
View on Left Front of ProFlow ATx System
View on Left Front of ProFlow ATx System