DIAGNOSTICS PROFLOW Chapter Issue 4, Aug 14 Technical Reference Manual 39.11 PROFLOW Selecting this diagnostics modul e opens the following window: The following icons are displayed: Next/Previous moves the highlight bar…

100%1 / 310
DIAGNOSTICS
PRINT CARRIAGE
39.10 Technical Reference Manual Chapter Issue 4, Aug 14
Drive Carriage to
Paste Position
Selecting this diagnostic function moves the print carriage to a position that
clears the paste dispense unit if operated. ‘Driving Print Carriage to Paste
Position’ is displayed in the prompt box.
Drive Carriage to
Rear Position
Selecting this diagnostic function moves the print carriage to the end of the print
stroke. ‘Driving Print Carriage to Rear Limit’ is displayed in the prompt box.
Drive Carriage
Using Jog Buttons
Selecting this diagnostic function allows the user to position the print carriage
anywhere between the front and rear position using the two jog buttons. ‘Use
the Left Jog Button to move Print Carriage towards front and the Right Jog
Button to move it towards the rear’ is displayed in the prompt box.
Cycle Print
Carriage
Selecting this diagnostic function starts a continuous cycle of driving the print
carriage between its front and rear limits, pausing at each end for 2 seconds.
‘Print Carriage Cycling’ is displayed in the prompt box. The cycle is terminated
if the Stop key is used or the set cycle count is reached.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count. The cycle count may be preset 5 -
9995 cycles (default 50) by selecting Adjust.
DIAGNOSTICS
PROFLOW
Chapter Issue 4, Aug 14 Technical Reference Manual 39.11
PROFLOW Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Home ProFlow Selecting this diagnostic function drives the ProFlow unit up to the home
position.
Drive System to
Contact Height
Selecting this diagnostic function drives the ProFlow unit onto the stencil, (a
slight pressure seal, is made between the ProFlow transfer head and the
stencil). There is no pressure applied to the paste cassette.
Drive System to
Print Height
Selecting this diagnostic function drives the ProFlow transfer head down to
printing pressure (as setup in the Edit Data board file). There is no pressure
applied to the paste cassette at this time.
Drive System
Using Jog Buttons
Selecting this diagnostic function enables the ProFlow unit to be moved up or
down by means of the jog buttons.
Toggle Air
Pressure
Selecting this diagnostic function initiates pressure onto the paste cassette.
Before initiating pressure to the paste cassette, the transfer head must be in
contact with, and have an adequate seal with the stencil. A warning is displayed
if toggle air pressure is selected with the transfer head off the stencil.
Toggle Auto Drip
Tray
Selecting this diagnostic function alternately energizes and de-energizes the
auto drip tray, displaying On when extended and Off when retracted. Reads Not
Fitted when feature is not installed.
Pressure Reading This diagnostic function continuously displays the current pressure in kg,
exerted from the squeegee pressure load cell onto the ProFlow unit.
ProFlow Diagnostics
11.42Kg
857
Home ProFlow
Drive System to Contact Height
Drive System to Print Height
Drive System Using Jog Buttons
Toggle Air Pressure
Toggle Auto Drip Tray
Pressure Reading:
ProFlow Fitted
Paste Cassette Low
ProFlow Pressure Regulator Fitted
Auto Drip Tray Retracted
ProFlow Transfer Material Level Reading:
OFF
ON
ON
OFF
OFF
ON
Run
Diagnost
Next
Previous
Exit
DIAGNOSTICS
PROFLOW
39.12 Technical Reference Manual Chapter Issue 4, Aug 14
ProFlow Fitted Indication of electrical connection of ProFlow to the printer software.
Paste Cassette
Low
ProFlow paste low sensor activated (on), indicating paste low or empty or,
deactivated (off).
ProFlow Pressure
Regulator Fitted
Switched to OFF indicates that the ProFlow unit is fitted with a mechanical
pressure regulator control. Switched to ON indicates that the software address-
able regulator control is activated, I ProFlow not fitted with mechanical pressure
regulator.
Auto Drip Tray
Retracted
This diagnostic function continuously displays the status of the auto drip tray
retracted sensor. Reads Not Fitted when feature is not installed.
ProFlow Paste
Level Reading
This diagnostic function continuously displays the current ProFlow paste level
sensor analogue value.