88192277-01-19 - Micron Technical Reference V9 Volume 4.pdf - 第107页
DIAGNOSTICS PASTE DISPENSE SYSTEM Chapter Issue 4, Aug 14 Technical Reference Manual 39.21 P ASTE DISPENS E SYSTEM Selecting this diagnostics modul e opens the following window: The following icons are displayed: Next/Pr…

DIAGNOSTICS
RAIL SYSTEM
39.20 Technical Reference Manual Chapter Issue 4, Aug 14
Cycle Board Clamp Selecting this diagnostic function starts a continuous cycle of clamping and
unclamping the board clamps. ‘Cycling Clamps....’ is displayed in the message
prompt box.
Cycle Rails Selecting this diagnostic function drives the moveable rail from the home
position to the minimum board width and back to the home position. ‘Cycling
Rails....’ is displayed in the message prompt box.
Board Stop in
Position
This diagnostic function continuously displays the status of the board stop
lowered sensor.
Board at Stop This diagnostic function continuously displays the status of the board at stop
sensor.
Board at Left This diagnostic function continuously displays the status of the board at left
sensor.
Board at Right This diagnostic function continuously displays the status of the board at right
sensor.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count. The cycle count may be preset 5 -
9995 cycles (default 50) by selecting Adjust.

DIAGNOSTICS
PASTE DISPENSE SYSTEM
Chapter Issue 4, Aug 14 Technical Reference Manual 39.21
PASTE DISPENSE SYSTEM
Selecting this diagnostics module opens the following window:
The following icons are displayed:
Next/Previous moves the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Carriage Home Selecting this diagnostic function drives the paste dispense carriage left to its
home position, as determined by its home sensor.
Drive Carriage to
Start Position
Selecting this diagnostic function drives the paste dispense carriage to the
position set by the paste start parameter.
Drive Carriage to
End Position
Selecting this diagnostic function drives the paste dispense carriage to the
position set by the paste stop parameter.
Drive Cartridge
Down
Selecting this diagnostic function drives the cartridge tilt motor down until the
cartridge away (down) sensor is detected.
Drive Cartridge Up Selecting this diagnostic function drives the cartridge tilt motor up until the
cartridge home (up) sensor is detected.
Toggle Paste
Dispense
Selecting this diagnostic function alternately applies and removes the air pres-
sure to the paste dispense cartridge, displaying On when air pressure is applied
and Off when air pressure is removed.
Paste Cartridge
Empty
This diagnostic function continuously displays the status of the cartridge empty
sensor.
Cartridge in Down
Position
This diagnostic function continuously displays the status of the cartridge away
(down) sensor.
Paste Cartridge Empty
Cartridge in Down Position
Cartridge in Up Position
OFF
OFF
Carriage Home
Drive Carriage To Start Position
Drive Carriage To End Position
Drive Cartridge Down
Drive Cartridge Up
Toggle Paste Dispense
Paste Dispense System Diagnostics
ON
ON
Run
Diagnost
Next
Previous
Exit

DIAGNOSTICS
PASTE DISPENSE SYSTEM
39.22 Technical Reference Manual Chapter Issue 4, Aug 14
Cartridge in Up
Position
This diagnostic function continuously displays the status of the cartridge home
(up) sensor.