4 Setting up and commissioning User Manual SIPLACE SX4/DX4 4.5 Adjusting the empty tape duct to the component height From software version SC.706.xx Version 0 6/2012 EN 230 4.5 Adjusting the empty t ape duct to the compo…

User Manual SIPLACE SX4/DX4 4 Setting up and commissioning
From software version SC.706.xx Version 06/2012 EN 4.4 Adjusting the component trolley to the PCB conveyor height
229
4.4.1 Warning instructions
WARNING 4
Only ASM Assembly Systems GmbH&Co.KG engineers or qualified personnel are permitted to
adjust the component trolley height.
Always follow the applicable accident prevention regulations.
Remove all the feeder modules from the changeover table, if you want to adjust the height for
the changeover table.
4.4.2 Tools and equipment
You will need the following tools and equipment to adjust the height of the component trolley:
– Mounting device (item no. 03015976-xx)
– Lifting device for raising the component trolley table, carrying capacity at least 80 kg
4.4.3 Changing the component trolley height
WARNING 4
Remove all the feeder modules from the changeover table.
Fit the mounting device to the changeover table in order to adjust the height. This prevents
the changeover table becoming deformed when the table is raised or lowered.
Fix the fit-up aid to the changeover table with the two M8 x 50 hexagon socket head screws.
There are two different holes available for the changeover table 60 and the changeover table
30.
Hook the leverage device into the eyelet.
Loosen the fastening screws and lift the changeover table into the required position.
Fit and tighten the fastening screws.

4 Setting up and commissioning User Manual SIPLACE SX4/DX4
4.5 Adjusting the empty tape duct to the component height From software version SC.706.xx Version 06/2012 EN
230
4.5 Adjusting the empty tape duct to the component
height
If feeder modules which use tapes with a pocket height of > 12 mm are used, remove the sepa-
rating plate (1).
4
(1) Separating plate for tapes > 12 mm, removable
(2) Fastening screws
WARNING 4
Switch the machine off at the main switch to remove the dividing plate.
Disconnect the machine from the power and compressed air supply.
Lock the machine to prevent unauthorized reactivation, as described in section 2.11, page 88.
Wait until the operating pressure for the tape cutter has dropped to 0 MPa.
Do not reach inside the empty tape duct.
Loosen the fastening screws.
Pull out the separating plate.
(1)
(2)

User Manual SIPLACE SX4/DX4 4 Setting up and commissioning
From software version SC.706.xx Version 06/2012 EN 4.6 Commissioning the machine
231
4.6 Commissioning the machine
4.6.1 Commissioning the machine at the customer's premises
Check all modules for correct seating.
Wipe off the linear guide rails with a lint-free cloth before removing the shipping braces for the
X/Y axis. Do not use any solvents (see section 4.3.10
, page 227).
Switch on the machine and perform a reference run.
Copy the placement program onto the computer and test it.
Check the machine zero point after a period of warming up of 3 - 4 h.
Get the customer's operating personnel to equip the feeder modules according to the cus-
tomer's placement program.
Instruct them in handling the feeder modules using the JobGuide.
Check all customer-specific installed options (in particular software) for good functioning and
order any necessary spare parts using the order form or by fax.
After installing the machine, perform Y mapping.
4.6.2 Instructing the customer's personnel
Explain all customer-specific installed options, in particular software / software compatibility.
Explain programming of the program editors on the line computer / SIPLACE Pro.
Instruct the operators and line engineers in using the station software.
Explain about password protection.
Instruct the customer's personnel according to the user manual and the preventive mainte-
nance.
4.6.3 A test run or starting production
Test the line using the test PCB or a PCB provided by the customer.
Record the customer product and performance data, prepare the data and document the data
in the installation report.
Secure the data and give the customer security copies.