00196693-03_UM_SX4DX4_SR706_EN.pdf - 第82页

2 Operational safety User Manual SIPLACE SX4/DX4 2.9 Disabling the compressed air supply and discharging the pressure From software version SC.706.xx Version 06/2012 EN 82 2.9 Disabling the compressed air supply and disc…

100%1 / 358
User Manual SIPLACE SX4/DX4 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.8 Residual voltages and discharge times in the machine
81
2.8.2 Residual voltages and discharge times after pressing the EMERGENCY
STOP button
2
2
CAUTION 2
To avoid losing data, assess the following criteria before switching off your machine (apart from in
emergencies):
Has the machine finished transmitting machine, setup and panel data?
Has the machine finished processing the PCB?
Has the machine completed the run-up phase?
Measuring point on the X200
distributor terminal block
Voltage in
normal mode
Residual voltage after
EMERGENCY STOP
Discharge
times
X200 - 4.a 150 V- < 10 VDC < 2s
X200-13.a 24 V- < 10 VDC < 2s
Interface-machine cable tree Voltage in
normal mode
Residual voltage if
main switch OFF or
power failure
Discharge
times
X21 - 1 260 V- < 10 VDC < 2s
X31 - 1 150 V- < 10 VDC < 2s
A8 ( positive connection) 42 V- (permanent) < 10 VDC < 2s
X18 - 7 42 V- (switched) < 10 VDC < 2s
X17 - 1 24 V- < 10 VDC < 2s
2 Operational safety User Manual SIPLACE SX4/DX4
2.9 Disabling the compressed air supply and discharging the pressure From software version SC.706.xx Version 06/2012 EN
82
2.9 Disabling the compressed air supply and discharging
the pressure
The compressed air working pressure of the machine is set to 0.50 ± 0.025 MPa (5.0 ± 0.25 bar).
The position of the compressed air unit is shown at item 1 in fig. 2.9 - 1
, page 83 ) The supply of
compressed air to the machine can be interrupted with the shutoff valve (item 2 in fig. 2.9 - 1
, page
83
).
Use the machine key to release the cover lock.
Lift the cover (see fig. 2.9 - 1, page 83 ).
Turn the lever of the shutoff valve (item 1 of fig. 2.9 - 1, page 83) from the vertical to the hor-
izontal position.
Monitor the operating pressure manometer (item 5 in fig. 2.9 - 1, page 83 ). When the machine
is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
CAUTION 2
When the machine is switched on, do not use the stop valve to interrupt the compressed air sup-
ply for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to
carry out preventive maintenance or servicing work, you must switch the machine off at the main
switch and disconnect it from the power supply.
User Manual SIPLACE SX4/DX4 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.9 Disabling the compressed air supply and discharging the pressure
83
2
Fig. 2.9 - 1 Compressed air unit on the machine
Legend for fig. 2.9 - 1
(1) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(2) Manometer for supply pressure of gantries 1 to 4
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(4) Stop valve in the "OPEN" position
(5) Compressed air filter
(6) Compressed air connection
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 2
(6)
(1)
(2)
(3)
(5)
(4)