00196693-03_UM_SX4DX4_SR706_EN.pdf - 第327页
User Manual SIPLACE SX4/DX4 6 Station extensions From software version SC.706.xx Version 06/2012 EN 6.5 Docking station for the component trolley of the SIPLACE X series 327 6.5.5 Adjusting the docking st at ion to the P…

6 Station extensions User Manual SIPLACE SX4/DX4
6.5 Docking station for the component trolley of the SIPLACE X series From software version SC.706.xx Version 06/2012 EN
326
Legend for fig. 6.5 - 4
, page 325.
(1) Control lamp for mains power supply
(2) Button for locking and unlocking all feeder modules on the component trolley
(3) Clamping lever for fastening the changeover table - lever in position "closed"
(4) Label with diagram of switch S1 and S2 for addressing the CAN bus
(5) Switch S1 and S2 for setting the CAN bus address
(6) Mains switch
(7) Rotary knob for setting the operating pressure
(8) Manometer for showing the operating pressure

User Manual SIPLACE SX4/DX4 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.5 Docking station for the component trolley of the SIPLACE X series
327
6.5.5 Adjusting the docking station to the PCB conveyor height
The component trolley docking unit of the docking station can be easily converted to PCB con-
veyor heights of 900, 930 and 950 mm.
6
Fig. 6.5 - 5 Adjusting the component trolley docking unit to the PCB conveyor heights
(1) Holes for the PCB conveyor height
(2) Hexagonal nut M8 and washer, 2x each
(3) Hexagonal nut M8 and washer, 2x each
(4) Hexagonal nut M8 and washer, 2x each
(5) Slot for height adjustment
(6) Hexagon socket-head screw M8x40, 6x
(7) Hexagon socket-head screw M5x12, 4x
(8) Guidance
(9) Hexagon socket-head screw M8x18, 2x
(10) Side panel, component trolley docking unit
(11) Cover on docking station
(12) Feeder module control unit (FCU)

6 Station extensions User Manual SIPLACE SX4/DX4
6.5 Docking station for the component trolley of the SIPLACE X series From software version SC.706.xx Version 06/2012 EN
328
6.5.5.1 Tools
You will need the following tools to adjust the height of the component trolley docking unit:
– Allen wrench, set
– Fork wrench, SW 13
6.5.5.2 Converting the component trolley docking unit to other heights
WARNING 6
Disconnect the docking station from the power supply.
Disconnect the docking station from the compressed air supply.
The weight of the component trolley docking unit is approx. 40 kg.
If required, enlist the help of a second person to help you with the conversion.
Follow the steps in the order described.
6.5.5.3 Converting the component trolley docking unit to heights of 900, 930 or 950 mm
6
Fig. 6.5 - 6 Order of conversion steps
Loosen the two hexagon socket-head screws M8x18 (item 9 in fig. 6.5 - 5, page 327) and re-
move the left and right guidance (item 8 in fig. 6.5 - 5
, page 327).