5 Working with the machine User Manual SIPLACE SX4/DX4 5.2 Controls and displays From software version SC.706.xx Version 06/2012 EN 238 Main power switch 5 The main power switch is used to switch the power supp ly to the…

User Manual SIPLACE SX4/DX4 5 Working with the machine
From software version SC.706.xx Version 06/2012 EN 5.2 Controls and displays
237
5.2 Controls and displays
5.2.1 Overview
5
Fig. 5.2 - 1 Controls and displays (example of SX4)
5.2.2 Description
All the controls can be reached by a 1.40 m tall person.
(1) Main power switch (5) Start button (green)
(2) Stop button (black) (6) LCD touchscreen
(3) EMERGENCY STOP button (7) Indicator lamps
(4) Keyboard (T) Direction of PCB transport
(1)
(2)
(3)
(5)
(6)
(7)
(7)
(4)

5 Working with the machine User Manual SIPLACE SX4/DX4
5.2 Controls and displays From software version SC.706.xx Version 06/2012 EN
238
Main power switch 5
The main power switch is used to switch the power supply to the machine on and off.
WARNING
Some parts inside the machine carry potentially lethal voltages - even when switched off at the
main power switch. 5
Stop button 5
This white button is used to stop the machine.
Start button (green) 5
This green button starts the machine after it has been switched on or after faults have been elim-
inated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the component trolleys, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
LCD touchscreen 5
There is a flat LCD screen with a touch-sensitive surface (touchscreen) on either side of the place-
ment machine.
Keyboard 5
The keyboard is located beneath the monitor.
CAUTION 5
Risk of collision on the monitor with keyboard
When working on the component trolley, there is risk that you could collide with the monitor and
keyboard.
– Turn the monitor and keyboard away to the side.
– Make sure that you are not under the monitor and keyboard with your head.
5

User Manual SIPLACE SX4/DX4 5 Working with the machine
From software version SC.706.xx Version 06/2012 EN 5.2 Controls and displays
239
Indicator lamp - two color (white/green) 5
The sequence of colors of the indicator lamps is white - green. These lamps are used to signal
operating statuses and malfunctions of the machine. See also Section 5.7 on page 257.
Indicator lamp - three color (red/yellow/green) 5
The sequence of colors of the indicator lamps is red - yellow - green. These lamps are used to
signal operating statuses and malfunctions of the machine. See also Section 5.7 on page 257.
5.2.3 Ergonomic arrangement of the controls
Fig. 5.2 - 1, page 237 provides an overview of the position of the controls. They are subdivided
into the following groups:
Operator panel at location 1 5
– LCD touchscreen
– Keyboard with trackball
– start button
– Stop button
– Main power switch
Operator panel at location 2 5
– LCD touchscreen
– Keyboard with trackball
– start button
– Stop button
5.2.3.1 Controls on the machine's operator panels
The two operator panel have identical control functions.
Monitor, keyboard, start and stop buttons 5
There is a monitor and a keyboard on both sides of the machine.
The start and stop buttons are located beneath the keyboard. The on-screen dialog will occasion-
ally prompt you to activate certain actions using buttons, and this arrangement will make it easier
for you both to activate and to interactively control these actions.
Main power switch 5
The main power switch is part of the power module. It is located here because it is only needed
for servicing and preventive maintenance work and is therefore not subject to frequent use.