6.3 PCB barcode scanner
Item no. 00519881-xx 2D board code reader
Item no. 00519839-xx Mechanics assembly set
Item no. 00519834-xx Electrics assembly kit for 2D board code reader
Item no. 00519880-xx 1D board barcode reader
Item no. 00519838-xx Mechanics assembly set
Item no. 00519833-xx Electrics assembly kit for 1D board barcode reader
6.3.1 Description
The PCB barcode reader is used to automatically record and decode barcodes on PCBs. The
PCB barcode scanners are installed on a special frame on the input side of the placement ma-
chine on the PCB
conveyor. Depending
on the position of the barcode strips, the barcode scanner can be attached in a few simple
steps so that the strips can be read parallel to or across the PCB transport direction.
When using dual conveyors, four board barcode readers can be retrofitted. These can scan both
the top or bottom of the boards on both conveyor lanes.
There are two variants of the barcode scanner:
– 1D board barcode readers
This barcode scanner processes barcodes. 6
– 2D board code reader
This code reader processes barcodes and matrix codes. Matrix code is primarily used when
there is
not enough space for barcode labels. 6
PLEASE NOTE:
A combination of 1D and 2D barcode reader and the 2D code reader in the same machine is not
possible. 6

User Manual SIPLACE SX4/DX4 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.3 PCB barcode scanner
319
6.3.2 Technical data - 1D barcode scanner
6
6.3.3 Technical data - 2D code reader
6
6
Dimensions (L x W x H)
40 x 30 x 20 mm
3
Weight 44 grams
Wave length 600 to 680 nm
Laser class Class 2, in line with DIN EN 60825-1, class II - CDRH
Scanning frequency 800 to 1200 scans/seconds
Code types Code 39, Code 128, Code 93,
Codabar, EAN, EAN 128, UPC,
2/5 Interleaved, Pharma Code, ISTB 128
Barcode length
Dual conveyor, asynchronous
Dual conveyor, synchronous
Max. 40 characters
Max. 40 characters
Data interface RS232, RS485
Electrical connection 15-pin D-Sub HD connector
Operating voltage 5 V- ± 5 %
Dimensions (L x W x H)
55 x 42 x 22 mm
3
Weight 125 grams
Code types 2D Data Matrix ECC 0, 50, 80, 100, 140 and 200
Data Matrix ECC200
QR Code, MicroQR Code
Barcode length
Dual conveyor, asynchronous
Dual conveyor, synchronous
Max. 40 characters
Max. 40 characters
Data interface RS232, USB 2.0
Electrical connection 15-pin D-Sub HD connector
Operating voltage 5 V- to 24 V-

6 Station extensions User Manual SIPLACE SX4/DX4
6.4 Mechanical stopper From software version SC.706.xx Version 06/2012 EN
320
6.3.4 Warning label W216 for 1D barcode reader
The 1D barcode reader is classified as a laser class 2 device.
6
Warning label W216 "laser class 2" for the 1D barcode reader,
item no. 03009347-01 (quantity per machine: up to 4)
PLEASE NOTE 6
When you install a PCB barcode scanner on the placement machine, you must attach laser
warning label W206 contained in the retrofit kit.
6.4 Mechanical stopper
Item No. 00519860-xx mechanical stopper
The mechanical stopper is fitted onto the sensor bar and can be moved mechanically. This stopper
is recommended if you want to use boards which have certain types of recesses on the front edge.
6
6
6
6
6
6
LASER RADIATION!
Do not look into beam
Laser class 2