00196920-07_SIPLACE_Pro_FeatureDescription_DE_EN.pdf - 第160页

SIPLACE Pro Fe ature Des cription Ausgabe 05/2014 Edit ion 160 In this c ase, the f ollowing option h as to be s et in the Li ne Edito r : Figure 9- 30 : Setting in the Line Editor The placem ent of the board top side wi…

100%1 / 350
SIPLACE Pro Feature Description Ausgabe 05/2014 Edition
159
Thus, the force 0,000 N is entered in the Edit tab and the Creep distance field is disabled. A value
may be entered for Spring compression.
Figure 9-28: Entering spring compression
This process is valid together with the station software as of the 707.x version and for the
C&P20 A, C&P20 M, C&P20 P and CPP placement heads.
9.3.6 Multiple Measurements with CPP Placement Head
Multiple measurements can be performed with the CPP placement head via the stationary camera
in Pick&Place mode. Thus, the component range has been extended.
9.3.7 Reading Barcodes on All Stations in the Line
The measuring steps to read the PCB barcodes with the PCB camera are always sent to all
stations in the line although some stations would already receive the barcodes through WDTL or by
reading them with an external barcode reader.
Additionally, the simulation has been optimized for the following special case:
Example
The line consists of three stations with an AOI system (Automatic Optical Inspection) in front of
station 3. The board has only one PCB barcode on the top side but panel barcodes / placement
positions on both sides. At the stations 1 and 3, external barcode readers are installed that can
only read from the bottom.
Figure 9-29: Example: stations in the line
The placement of the board bottom side is simulated as follows:
– The PCB barcode on the board top side is read by the external barcode reader in station 1.
– The panel barcodes are read by the PCB camera in PA1.
– All barcodes are passed over to station 2 through WDTL.
– At station 3 the PCB barcode is read by the external barcode reader and the panel barcodes
are passed over through WDTL.
For placement of the board top side it has to be considered that an external barcode reader is
installed at station 3 which can only read from the bottom. Thus, it cannot be used for placing the
board top side.
SIPLACE Pro Feature Description Ausgabe 05/2014 Edition
160
In this case, the following option has to be set in the Line Editor:
Figure 9-30: Setting in the Line Editor
The placement of the board top side will then be simulated as follows:
– The PCB barcode on the board top side is read by the PCB camera in PA1 of station 1.
– Additionally, the panel barcodes are read by the PCB camera in PA1.
– All barcodes are passed over to station 2 through WDTL.
– At station 3 the PCB barcode is read by the PCB camera in PA1.
If a station software version <= 706 runs on station 3, all panel barcodes are read in PA1, too.
If a station software version as of 707 runs on station 3, the panel barcodes will be passed over
by station 2 through WDTL.
9.3.8 SIPLACE LED Pairing – Enhancements
The following sections give an overview of enhanced features in SIPLACE LED Pairing.
Detailed information about the single features can be found in the SIPLACE LED Pairing User
Guide.
9.3.8.1 Wildcard Character '*' as Reference Designator
The '*' wildcard character can be used as reference designator in the LED matrix file.
9.3.8.2 Creating a Partial Setup
Multiple recipes can be selected in the Production view, whereupon SIPLACE LED Pairing
generates one download recipe for each selected recipe. If the selected recipes have the same
recipe template, SIPLACE LED Pairing will create one common setup for the download recipes.
Optionally, a partial setup may be created out of it via a new button. All components that are not
required in the download recipes will then be removed from the setup together with their feeders.
9.3.8.3 Controlled Transfer of Changes from Copied Placement Lists
SIPLACE LED Pairing creates copies of the placement lists. If errors are detected in the data
during placement, the user usually corrects them only in the copy.
In order to transfer such changes controlled to the original placement lists, it is now possible to start
the Difference Editor in SIPLACE LED Pairing via a new button in the Production view.
The relevant placement lists are displayed for comparison and the correction can be performed in
the Difference Editor.
SIPLACE Pro Feature Description Ausgabe 05/2014 Edition
161
9.3.9 Line Control GUI – Enhancements for SIPLACE Order Manager
The Line Control GUI of SIPLACE Pro has been enhanced and displays information about the
SIPLACE Order Manager.
9.3.9.1 Displaying Board Comments in the Production Schedule
Such information as oven profiles and screen printer numbers is very important at the line in order
to decide the best production sequence for the recipes within family setups. Comments may be
entered in the board description for such process attributes and will then be displayed as additional
columns in the production schedule on the Line Control GUI.
At first, the comment columns have to be defined and enabled in the Line Control GUI under
Configuration – Application – Columns:
Figure 9-31: Defining and enabling comment columns
When enabling the Comments option and clicking on the Configure... button, the following dialog
box will open in which the rules for the comment columns can be defined.