SIPLACE Pro Fe ature Des cription Ausgabe 05/2014 Edit ion 72 5.21 Restricti ng the Amount of Data during Import /Export of XML Files You can c hange the defau lt setting of 50 MB yte under t he Tools => S ettings =&g…

SIPLACE Pro Feature Description Ausgabe 05/2014 Edition
71
5.19 The SiCluster Optimization Tool (Option)
In SIPLACE Pro 7.1 the existing Cluster Job Wizard is replaced by the SiCluster optimization
tool. A license is required to use these functions.
Start SIPLACE Pro Optimizer Toolkit => SiCluster.
SiCluster is an optimization tool with a reduced scope of functions compared to SiCluster
Professional. In SiCluster it is not possible to optimize constant tables when creating setups.
With SiCluster you generate a cluster job instead of a job. In doing so, the PCBs are distributed to
several (as few as possible!) setups, taking all side conditions into account. If it is your task to
determine the smallest number of setups for your products to be produced, you use the SiCluster
optimization tool.
Refer to the online help of the SIPLACE Pro Optimizer Toolkit for more detailed information.
5.20 Setting the Specific Feeder Pitch
In the component, the component shape or the setup, it is now possible to set a feeder specific
value for the Feeder Pitch. That means that the Feeder Pitch for component shape or component
can be set differently for each assigned feeder. In addition, the Feeder Pitch can now be changed
in the setup without having to change the values in the component editor or the component shape
editor.
The feeder pitches that are allowed for the feeder are presented in a list. If other values or zero is
being entered, this is indicated by an appropriate icon.
SIPLACE Pro Feature Description Ausgabe 05/2014 Edition
72
5.21 Restricting the Amount of Data during Import /Export of XML
Files
You can change the default setting of 50 MByte under the Tools => Settings => General settings
tab.
5.22 Optimizing of Standard and Long Boards
If, in one setup, normal PCBs were produced with the "Long board" option, problems during
optimization could occur. It is now possible, to optimize long and normal PCBs together in the
same initial setup. The "Long board" option can now be enabled for normal PCBs.
5.23 Determining the Load Factor of the Placement Areas During
Optimization
During optimization, the calculation of the placement content in the placement heads can be
influenced by the Load Factor. This means, that the optimization will distribute more or fewer
placements to the respective placement heads in the placement area.
You can enter the Load Factor in the Setup Editor => Location => Simulation tab.
5.24 Improving the Usability of SIPLACE Pro Desk
5.24.1 Deleting Directories in the Tree Structure
If a directory is deleted using this function, all objects in all subdirectories are deleted, too. There is
the possibility to delete only those objects and their subdirectories that are no longer used.
SIPLACE Pro Feature Description Ausgabe 05/2014 Edition
73
New and Modified Functions (V7.1 SP1)
5.25 Improving the Usability
5.25.1 Assigning Alternative Feeders in the Table Editor
If alternative feeders are entered in the component shape or the component, these are displayed in
the context menu of the table list and can be newly assigned there. If the alternative feeder cannot
be set up on the table (e. g. for there is not enough space), this feeder is copied into the clipboard.
The user can change the table assignment manually and put the feeder from the clipbaord onto the
table later on.
5.25.2 Show Non Collision Nozzles Types
The Precedence Finder now shows Non Collision Nozzles Types.
5.25.3 Replace of Nozzles
Using the Component Shape and Fiducial Upgrade Tool one can replace assigned nozzles for all
of the existing component shapes.
5.25.4 Stationwise Download
The function stationwise download is now supported for station software from 703.xx onward.
5.26 Identical Nozzle Changer Configuration
In SiCluster Professional it is optionally possible to create an identical nozzle changer configuration
for all setups. In the previous version this was only possible for constant tables using the runtime
intensive option for re-optimizing constant tables.
5.27 Multi-Clusterjob-Optimizer
The Multi-Clusterjob-Optimizer is an efficient tool with which you can process cluster jobs in batch
mode. The single cluster jobs get inserted into the cluster job list from the cluster job tree and can