IPC-TM-650 EN 2022 试验方法--.pdf - 第585页

Example Figure 3 Flex Circui t Containing Fo ur ACF Bo nd Sites, After Being Bonded to a Glass Sl ide Figure 4 Schema tic Diagram for Insulation Resistivity Measurement IPC-TM-650 Number Subject Date Revision Page 2 of 2…

100%1 / 824
Figure 1 Suggested Flex Circuit Layout for Insulation
Resistance Test
Figure 2 Preattachment of the ACF Strips to the Flex
Circuit
The Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062
Material in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
Page 1 of 2
Number
Testable
Area
should
be
25mm
IPC-TM-650
TEST
METHODS
MANUAL
1
Scope
The
purpose
of
this
test
method
is
to
quickly
assess
the
adequacy
of
a
given
Anisotropically
Conductive
Adhesive
Film
(ACF)
construction
and
bonding
process
for
avoiding
short
circuits
between
adjacent
traces
of
a
flex
circuit
being
bonded
to
a
low
profile
circuit
substrate.
1.1
Purpose
ACF
materials
are
often
used
to
interconnect
fine-pitch
flexible
circuitry
to
substrates
such
as
flat-panel
dis¬
plays.
A
center
to
center
pitch
range
of
80
pm
to
200
pm
is
not
uncommon
in
circuits
for
flat
panel
display
applications.
It
is
critical
that
the
particle
dispersion
within
the
ACF
be
of
suf¬
ficient
quality
such
that
there
is
no
inherent
tendency
for
short
circuits
between
adjacent
traces.
In
addition,
it
is
important
that
a
bonding
process
is
used,
which
doesn't
create
any
undue
accumulation
of
particles,
which
will
lead
to
short
cir¬
cuits.
2
Applicable
Documents
None
2.5.10.1
Subject
Insulation
Resistivity
for
Adhesive
Interconnection
Bonds
Date
Revision
11/98
Originating
Task
Group
SMT
Mounting
Adhesives
Task
Group
(5-24d)
3
Test
Specimens
3.1
In
order
to
perform
this
test,
a
custom-designed
and
fabricated
flex
circuit
substrate
will
need
to
be
produced.
A
suggested
flex
circuit
construction
of
a
design
is
shown
in
Figure
1
.
Flex
circuit
materials
should
be
selected
to
be
repre¬
sentative
of
what
is
being
used
in
the
application.
The
traces
alternate
between
anodic
and
cathodic
polarity
as
shown.
Trace
thickness,
width,
and
pitch,
should
be
selected
in
accordance
with
the
application.
Total
trace
count
should
be
at
least
1
00,
and
total
width
of
the
pattern
should
be
slightly
less
than
the
thermode
length.
Total
length
of
the
traces
should
be
sufficient
to
allow
at
least
four
bonds
to
be
accom¬
modated
as
shown
in
Figure
2
and
Figure
3.
N
is
the
number
of
circuit
traces
(at
least
100).
I
is
the
measured
leakage
current
in
amps
after
10
seconds
@
50V.
g
is
the
gap
spacing
between
adjacent
traces
on
the
circuit
in
mm
(of
the
order
0.04
mm
to
0.1
mm).
wi
a
h
IPC-2-5-1
0-1-1
IPC-2-5-10-1-2
Example
Figure 3 Flex Circuit Containing Four ACF Bond Sites,
After Being Bonded to a Glass Slide
Figure 4 Schematic Diagram for Insulation Resistivity
Measurement
IPC-TM-650
Number
Subject Date
Revision
Page 2 of 2
2.5.10.1
Insulation
Resistivity
for
Adhesive
Interconnection
Bonds
11/98
4
Apparatus
4.1
DC
power
supply
capable
of
providing
voltage
in
the
range
of
1
0
V
to
100
V,
with
an
accuracy
of
at
least
±
10%,
and
capable
of
supplying
current
in
the
range
of
0
mA
to
1
mA
at
those
voltage
levels
4.2
DC
ammeter
capable
of
measuring
current
in
the
range
of
0
to
1
mA,
with
an
accuracy
of
0.001
mA
4.3
Stopwatch
or
other
timing
mechanism
capable
of
resolving
±
1
second
4.4
Hot-bar
bonds
capable
of
producing
ACF
bonds
between
flex
circuits
and
flat
panel
displays,
and
outfitted
with
a
thermode
of
appropriate
length
and
width
for
a
given
appli¬
cation
(Thermode
width
is
generally
in
the
range
of
2
mm
to
3
mm,
and
length
is
in
the
range
of
25
mm
to
50
mm.)
5
Procedure
5.1
Calculate
the
insulation
resistivity
(pi)
in
Ohm-cm
for
each
of
three
samples.
Each
sample
must
meet
the
specifica¬
tion
requirement
(see
Figure
4).
where:
(A)(B)(C)(D)(E)
(F)(G)(H)
=
Q
-
cm
A
voltage
B
number
of
bonds
C
=
width
of
bond
(mm)
D
=
conductor
thickness
(mm)
E
=
total
number
of
lines
-
1
F
=
mm
to
pm
conversion
G
current
amps
H
=
trace
to
trace
gap
(mm)
A
test
circuit
is
designed
with
100
total
circuit
traces
(50
anodic
and
50
cathodic)
on
100
pm
pitch.
The
trace
thickness
is
0.035
mm
(1
oz
Cu)
and
the
trace
to
trace
gap
is
0.05
mm.
Suppose
also
that
four
ACF
bonds
are
pre¬
pared,
with
each
bond
being
3
mm
wide.
After
applying
a
50
VDC
bias
for
10
seconds,
a
leakage
current
of
0.5
mA
is
measured.
pi
=
(50)(4)(3)(0.035)(99)
(10)(0.0005)(0.050)
=
8.3E6
Q
-
cm
50
VDC
±
10%
IPC-2-5-10-1-4
Figure 1 Distance from Clips
The Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062
Material in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
Page 1 of 1
IPC-TM-650
TEST
METHODS
MANUAL
1
Scope
This
test
method
determines
electrical
resistance
of
multilayer
PWBs.
2
Applicable
Documents
None
3
Test
Specimen
3.1
Test
coupon
"G”
4
Equipment/Apparatus
4.1
A
four-terminal
Kelvin
Bridge
or
equivalent
5
Procedure
5.1
Test
5.1.1
Measure
the
resistance
between
any
two
adjacent
holes
in
row
A
or
E
of
Specimen
G,
except
holes
A5
&
6,
E3,
4,
11
,
and
12
(see
Figure
1).
Diagram
A
(The
distance
between
dip
and
hole
should
be
as
short
as
possible.)
Number
2.5.12
Subject
Interconnection
Resistance,
Multilayer
Printed
Wiring
Date
Revision
4/73
Originating
Task
Group
N/A
5.1.2
Solder
leads
in
the
selected
holes
for
proper
connec¬
tion
to
the
four
terminals
of
the
test
instrument
according
to
diagram
A.
5.1.3
Repeat
this
test
for
each
of
the
five
pairs
of
holes.
5.2
Evaluation
Record
and
report
all
electrical
resistance
values.
I
PC-2-5-1
2-1