IPC-TM-650 EN 2022 试验方法--.pdf - 第779页

NOTE: IPC-TM-650 Page 2 of 2 Number 3.1 Subject Contact Resistance, Connectors Date 7/75 Revision A D. Solder Tab — On the printed wiring traces as close to the termination as practicable. E. Press-Fit — On the pad of th…

100%1 / 824
NOTE:
Figure 1 Test Set-up
Material in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
Page 1 of 2
ASSOCIATION
CONNECTING
/
ELECTRONICS
INDUSTRIES
221
5
Sanders
Road
Northbrook,
IL
60062-61
35
IPC-TM-650
TEST
METHODS
MANUAL
1
.0
Scope
1.1
To
evaluate
the
contact
resistance
of
electrical
contacts
at
rated
current.
2
.0
Reference
Documents
2.1
Information
in
this
section
is
intended
to
parallel
the
test
method
described
in
EIA-RS-364/TP-06.
3
.0
Test
Specimen
3.1
The
mated
contacts
of
a
connector
mounted
and,
when
required,
terminated
in
its
normal
manner
or
a
mated
pair
of
individual
contacts.
When
mated
contact
pairs,
not
requiring
housings,
are
tested,
they
shall
be
rigidly
mounted
in
a
fixture
to
provide
mechanical
stability
and
to
insure
proper
mating
and
orienta¬
tion.
3.2
For
contacts
having
a
wire-hole,
crimp
or
other
termina¬
tion,
a
3-foot
length
of
continuous
wire
may
be
used
for
heat
dissipation.
The
wire
size
shall
be
specified
in
the
individual
contact
or
connector
specification.
3.3
Voltage
connections
may
be
attached
permanently
by
soldering,
crimping,
or
other
suitable
method.
3.4
Unless
otherwise
specified
in
the
individual
contact
or
connector
specification,
the
test
sample
shall
not
be
cleaned
by
any
means
prior
to
the
test
nor
shall
any
lubricants
or
other
coatings
be
applied.
4
.0
Apparatus
4.1
Voltmeter
(10000
ohms
per
volt
or
greater)
The
meter
accuracy
shall
be
such
that
the
voltage
value
is
mea¬
sured
accurately
within
5
percent.
4.2
Ammeter
The
meter
accuracy
shall
be
such
that
the
current
value
is
measured
accurately
within
5
percent.
4.3
Power
supply
capable
of
delivering
the
required
test
cur¬
rent.
Number
3.1
Subject
Contact
Resistance,
Connectors
Date
Revision
7/75
A
Originating
Task
Group
N/A
5.0
Procedure
5.1
The
contact
resistance
test
shall
be
conducted
using
a
circuit
as
shown
in
Figure
1
.
5.2
The
current
through
the
test
sample
shall
be
increased
to
the
value
specified
in
the
individual
contact
or
connector
specification
and
shall
be
maintained
until
temperature
stabili¬
zation
of
the
test
sample
at
that
current
is
attained.
Tempera¬
ture
stability
may
be
indicated
by
voltage
drop
stability.
5.3
The
voltage
drop
across
each
pair
of
mated
contacts
shall
be
measured
with
the
voltmeter
probes
(or
permanent
connection)
positioned
as
follows:
A.
Wire-Hole
On
the
contact
with
1/8
inch
of
insulator.
B.
Wrap-Post
On
the
wrap-post
adjacent
to
the
outer
turn
of
wire.
C.
Crimp
On
the
wire
(piercing
the
insulation)
within
1/8
inch
of
insulator.
NOTE:
IPC-TM-650
Page 2 of 2
Number
3.1
Subject
Contact
Resistance,
Connectors
Date
7/75
Revision
A
D.
Solder
Tab
On
the
printed
wiring
traces
as
close
to
the
termination
as
practicable.
E.
Press-Fit
On
the
pad
of
the
plated-through
hole
as
close
to
the
termination
as
practicable.
If
the
pad
of
the
printed
wiring
board
constitutes
one-half
of
the
mated
contact
pair,
the
voltmeter
probe
shall
be
posi¬
tioned
on
the
pad
immediately
adjacent
to,
but
not
touching,
the
mating
contact
(not
inside
the
insulator).
In
case
of
an
environment
resistant
(sealed)
connec¬
tor,
the
voltmeter
probes
shall
be
positioned
as
close
to
the
sealing
grommets
as
practicable.
5.4
The
contact
resistance
shall
be
calculated
by
dividing
the
voltage
drop
reading
by
the
current
reading.
The
value
thus
obtained
for
each
contact
shall
not
exceed
the
maximum
allowable
contact
resistance
as
defined
in
the
individual
con¬
tact
or
connector
specification.
5.5
For
voltage
drops
less
than
1.0
millivolt,
the
voltage
drop
across
each
pair
of
mated
contacts
with
the
current
succes¬
sively
in
both
directions
through
the
test
specimen
shall
be
measured.
The
contact
resistance
shall
be
calculated,
in
each
the
forward
and
reverse
directions,
by
dividing
the
voltage
drop
reading
by
the
current
reading.
The
average
of
the
two
resistance
values
thus
obtained
for
each
contact
shall
not
exceed
the
maximum
allowable
contact
resistance
as
defined
in
the
individual
contact
for
connector
specification.
6.0
Notes
6.1
Acceptance
criteria
shall
be
established
as
the
maxi¬
mum
level
at
which
stable
electrical
contact
is
maintained.
This
resistance
is
an
inherent
characteristic
of
any
given
con¬
nector
contact
design
and
is
(when
the
connector
is
properly
applied)
well
below
that
resistance
level
required
for
circuit
function.
NOTE:
NOTE:
Material in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
Page 1 of 1
ASSOCIATION
CONNECTING
/
ELECTRONICS
INDUSTRIES
221
5
Sanders
Road
Northbrook,
IL
60062-61
35
IPC-TM-650
TEST
METHODS
MANUAL
1
.0
Scope
1.1
To
determine
the
ability
of
electrical
contacts
to
with¬
stand
forces
tending
to
displace
them
from
their
proper
loca¬
tion
within
the
connector
insert
and
to
resist
contact
pull
out.
These
forces
may
be
the
result
of
(a)
loads
on
wire
connected
to
the
contact,
(b)
forces
required
to
restrict
contact
"push
through"
during
assembly
of
removable
type
contacts
into
connector
inserts,
during
assembly
of
removable
type
con¬
tacts
into
connector
inserts,
(c)
forces
produced
by
mating
of
contacts
during
connector
mating,
(d)
dynamic
forces
pro¬
duced
by
vibration
and
shock
during
normal
use
of
the
con¬
nectors,
and
(e)
forces
relating
to
bundling
strains
on
wire.
2
.0
Reference
Documents
2.1
Information
in
this
section
is
intended
to
parallel
the
test
method
described
in
EIA-RS-364/TP-29.
3
.0
Test
Specimen
3.1
A
plug
and/or
receptacle
with
a
full
complement
of
con¬
tacts.
4
.0
Apparatus
4.1
Force
gauge,
of
suitable
range
and
accuracy
to
provide
measured
values
accurate
within
2
percent.
4.2
Contact
removal
and
insertion
tools
as
required
by
the
connector
specification.
4.3
Steel
test
probes
to
adapt
the
force
gauge
plunger
to
the
front
or
wiring
end
of
the
particular
contact
(male,
female,
or
hermaphroditic)
under
test.
Number
3.2
Subject
Contact
Retention,
Connectors
Date
Revision
7/75
A
Originating
Task
Group
N/A
5
.0
Procedure
All
contact
positions
of
the
insert
shall
be
filled
during
this
test.
5.1
All
back
shell
hardware
and
compression
rings
shall
be
removed
to
expose
the
wire
side
of
the
connector.
5.2
If
possible,
the
test
shall
be
conducted
before
wires
have
been
attached
to
the
contacts.
5.3
The
un
mated
plug
or
receptacle
shall
be
mounted
such
that
an
axial
load
can
be
applied
by
the
force
gauge.
A
mini¬
mum
of
1/4
inch
clearance
shall
be
provided
on
the
opposite
side
of
the
insert
to
permit
any
"push
through”
that
might
occur.
The
direction(s)
in
which
the
test
is
to
be
conducted
shall
be
determined
from
the
individual
connector
specifica¬
tion.
If
two-directional
testing
is
required,
the
specified
number
of
samples
shall
be
divided
into
equal
groups
(one
group
for
each
test).
5.4
An
axial
load
shall
be
applied
to
the
contact
at
a
rate
of
approximately
one
pound
per
second
until
the
force
speci¬
fied
in
the
detail
specification
is
reached.
The
specified
force
shall
be
maintained
for
a
minimum
of
five
(5)
seconds.
6
.0
Notes
6.1
Acceptance
criteria
shall
be
established
in
terms
of
(a)
the
difference
in
contact
position
before
and
during
the
appli¬
cation
of
the
specified
axial
force
and/or
(b)
the
difference
in
contact
position
before
and
after
the
application
of
the
speci¬
fied
axial
force.
4.4
Device
for
applying
the
required
load.