JUKI贴片机错误代码集合.pdf - 第100页
cannot be executed .” “ 只有左 边站台,存在吸取位置, | 左边站台上没 有可用吸嘴, | 不能进行生产。 ” E500266 “ The adsorption position is only at a left station.|The use nozz le is not at a ri ght station.|Producti on cannot be executed .” “ 只有右 边站台,存在吸…
specification in the production program.)”
“在设置中,左站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定左 Head)。”
E500248 “It is a setup and a right station is unused.|Production cannot be executed.(There is Right head
specification in the production program.)”
“在设置中,右站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定右 Head)。”
E500250 “The head which can be used does not exist.|Production cannot be executed.”
“不存在可用 Head。|不能进行生产。”
E500251 “Because the OCC is unused, the mark recognition cannot be executed.|Production cannot be
executed.”
“因没使用 OCC,不能识别标记。|不能进行生产。”
E500252 “The station which can be used does not exist.(It is the setup data and both stations are
unused.)|Production cannot be executed.”
“不存在可用站台。(在设置中,没有使用两边站台) |不能进行生产。”
E500253 “The use nozzle is not in ATC.|Production cannot be executed.”
“在 ATC 上不存在要使用的吸嘴。|不能进行生产。”
E500260 “There is no adjustment in setting the use unit.|Production cannot be executed.”
“使用单元的设置不匹配。|不能进行生产。”
E500261 “The adsorption position is only at a left station.|(A left station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有左边站台上,存在吸取位置|(没有使用左边站台的(Head,OCC, 站台)),|不能进行
生产。”
E500262 “The adsorption position is only at a right station.|(A right station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有右边站台上,存在吸取位置|(没有使用右边站台的(Head,OCC, 站台)),|不能进行
生产。”
E500263 “The use nozzle is only at a left station.|(A left station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有左边站台,存在可用吸嘴|(没有使用左边站台(Head,OCC,站 台 )),|不能进行生产。”
E500264 “The use nozzle is only at a right station.|(A right station (head or OCC or station) is
unused.)|Production cannot be executed.”
“只有右边站台,存在可用吸嘴|(没有使用右边站台(Head,OCC, 站台)),|不能进行生产。”
E500265 “The adsorption position is only at a left station.|The use nozzle is not at a left station.|Production
cannot be executed.”
“只有左边站台,存在吸取位置,|左边站台上没有可用吸嘴,|不能进行生产。”
E500266 “The adsorption position is only at a left station.|The use nozzle is not at a right station.|Production
cannot be executed.”
“只有右边站台,存在吸取位置,|右边站台上没有可用吸嘴,|不能进行生产。”
E500270 “Smaller layer than the layer of the entrance side station exists in the installing data of the exit side
station.”
“出口侧站台的贴片数据上,存在比入口侧站台小的阶层。”
E500271 “It is the data which the exit side station installs earlier than the entrance side station.|Production
cannot be executed.”
“出口侧站台存在比入口侧站台先贴片的数据,|不能进行生产。”
E500272 “There is no adjustment in setting the adsorption position and the use unit.|Production cannot be
executed.”
“吸取位置或使用单元的设置不一致,|不能进行生产。”
E500300 “Origin retrieval has not yet been completed”
“尚未完成返回原点。”
[Cause]
You tried to resume the production without completing the Origin retrieval after an unexpected stop
such as Emergency stop.
[Treatment]
Please perform the Origin retrieval by pressing the ORIGIN button on the operation panel.
E500301 “Servo is turned OFF”
“伺服被关闭。”
[Cause]
The production can not be executed since the Servo is free.
[Treatment]
Please perform the Origin retrieval by pressing the ORIGIN button on the operation panel.
E500302 “Air was down”
“气压被下降。”
[Cause]
The air pressure is getting down.
[Treatment]
Please adjust the air pressure to its original level.
E500303 “Detected %s feeder float”
“发现%s 上传送带浮动。”
[Cause]
A matter that may interrupt the Feeder floatation sensor occurred.
where the matter occurred.
‧On the front side
‧On the rear side
‧On both sides
[Treatment]
Please remove the obstruction that may be interrupting the sensor.
E500304 “The servo power supply does not enter for the cover opening. |Please close the cover.”
“因机盖被打开,不能启动起动伺服。|请关闭机盖。”
E500305 “The servo power supply does not enter for the bank descent. |Please raise the bank.”
“因送料器台架被下降,不能启动伺服。|请台升送料器台架。”
E500400 “Machine was gone to abnormal state”
“机器有些不正常。”
E500401 “Input order Simple Opt. Error <%s>“ “建立进度表数据出错 |<%s>“
[Cause]
An error occurred while optimizing the pick positions by input orders.
The details of the error
1. There is no component corresponding to the feeder.
2. The head can not travel to the feeder/MTC position.
3. The head can not travel to the holder/MTS position.
4. There is no head available to place the component.
5. There is no head that meets the centering type.
6. An internal error of the Input order Simple Opt. Error process.
[Treatment]
1 and 6 are a program error. Please make a note of the cause of the error and the error code, then
contact our technical service Dept. for information.
In case of 2, 3, and 4, please go to the Production Program Editor and see the specified head(s) in the
Placement data.
In case of 5, please go to the Production Program Editor and see the centering type in the Component
data.
E500402 “An error occurred in the checking prior to the production. |<%s>“
“在生产开始之前的检测中发生错误。|<%s>“
E500403 “Machine was gone to abnormal state.|The process gets discontinued. |Please put the power supply