JUKI贴片机错误代码集合.pdf - 第223页

E610221 “ X Linear scale alarm occurred ” “ 发生 X 线性刻度警报。 ” [Cause] An abnormal matter ha ppened to t he linear scale of X axis. [Treatment] Please turn off the power supply of your machine. If the error occurs even after…

100%1 / 464
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of YR axis with a new one.
E610218 YCNV Driver alarm occurred
发生 YCNV 驱动警报。
[Cause]
An abnormal matter happened to the servo driver on the right movable station of the PWB conveyor.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the servo driver on the right movable station of the PWB conveyor with
a new one.
E610219 X SLOW occurred
发生 X 轴低速。
[Cause]
Left and right heads got too close and the sensor got ON to prevent the left and right heads from
clashing with each other. Therefore, the axis was forced to stop travel slow.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, the following causes can be possible.
‧A light reflective sensor detects if the left and right heads get too close with each other or not.
Please make sure that there is nothing that the sensor reacts to.
‧The sensitivity of the sensor is too high. Please adjust the sensitivity control volume on the sensor
to make it that the sensor gets on when the distance between the heads gets less than 230mm.
‧The sensor is broken. It could be that a sensor cable came off the connector, that a cable got cut off,
or that the sensor itself is broken.
‧The MCM board in the sensor is broken.
E610220 X STOP occurred
发生 X 轴停止。
[Cause]
Left and right heads got too close and the sensor got ON to prevent the left and right heads from
clashing with each other. Therefore, the axis was forced to stop traveling.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, the following causes can be possible.
‧The sensor is broken. Please examine if the sensor cable came off the connector, the cable got cut
off, or the sensor itself is broken.
‧The MCM board in the sensor is broken.
E610221 X Linear scale alarm occurred
发生 X 线性刻度警报。
[Cause]
An abnormal matter happened to the linear scale of X axis.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the detecting part or the amplifier part of the Linear scale with a new
one.
E610222 XR Linear scale alarm occurred
发生 XR 线性刻度警报。
[Cause]
An abnormal matter happened to the linear scale of XR axis.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the detecting part or the amplifier part of the Linear scale with a new
one.
E610223 Y Linear scale alarm occurred
发生 YL 线性刻度警报。
[Cause]
An abnormal matter happened to the linear scale of YL axis.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the detecting part or the amplifier part of the Linear scale with a new
one.
E610224 YR Linear scale alarm occurred
发生 YR 线性刻度警报。
[Cause]
An abnormal matter happened to the linear scale of YR axis.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the detecting part or the amplifier part of the Linear scale with a new
one.
E610225 Fan stop error occurred
发生风扇被停止错误。
[Cause]
The cooking fan stopped.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the cooling fan with a new one.
E610226The air pressure decrease error occurred
发生气压下降错误。
[Cause]
The air pressure is decreasing.
[Treatment]
The following causes can be possible. Please deal with the error based on the cause you have.
‧The air supplied to the unit is decreasing. The air pressure that should be supplied is 0.5  
0.05Mpa, so please see if the proper amount of air pressure is supplied or not.
‧The enough amount of the air necessary for the unit is not being supplied. This error is likely to
occur when a pipe to the unit is too thin or the capacity of the air compressor is too small. These two
can be the cause of the error especially when large components are picked simultaneously. You
need to deal with the air by replacing the pipe to the unit with a larger one.
‧The air regulator is wrung toward its minimum limit too much. Please loosen the air regulator to
make it 0.5   0.05Mpa.
‧The set value for the air pressure detecting sensor is too low. Please reset the value of the sensor
that is installed next to the air combination to 0.45Mpa.
‧The air pressure detecting sensor is broken. Please examine if a connecting cable connects to the
connector properly. If the cable connects to the connector properly, the sensor itself is broken.
E610227 The error not forecast occurred
发生未知错误。
[Cause]
An undefined error occurred.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610228 LZ1 Driver alarm occurred
发生 LZ1 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head1.
[Treatment]