2 If the PWB overran the WAIT sta tion and got conveyed to t h e center station when the error occurred. The WAIT sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and then select [Contro…

100%1 / 464
the PWB when the error occurred.
1) If it is possible to change the stop position on the machine in the upper part of the line, please
make a modification not to make a PWB overrun to get detected by the IN sensor.
2) If it is not possible to change the stop position on the machine in the upper part of the line, please
move the IN sensor to the inner side of the machine so that a PWB will not get detected by the sensor
even if the board overruns.
2 The PWB had not been detected by the IN sensor when the error occurred (the PWB got to the
right position on the machine in the upper part of the line, and then the error occurred).
There is a possibility that the IN sensor is detecting something else if the IN sensor does not get OFF
even if the machine in the upper part of the line is conveying the PWB properly. Please select
[Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of IN sensor in the 'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor.
2) A If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came out of the connector part, that a contact pin of the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650224 PWB Conveying Error : PWB conveying time out error of Input buffer. The process is forcibly
terminated. Please remove on the conveying route
传送基板错误 :|入口缓冲区搬入基板超过时间。
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN and WAIT sensors when the error
occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB overran the WAIT station and got conveyed to the center station when the error
occurred.
The WAIT sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
WAIT sensor in the 'Status' frame.
1) There is a possibility that the WAIT sensor is broken. It could be that the wiring came out of the
connector part, that a contact pin of the connector part is broken, that wiring got cut off, or that sensor
itself is broken. Please examine the wiring and the connector. If any of them are broken, you need to
replace them with the new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650225 PWB Conveying Error :| Shutter time out error of IN buffer.”
传送基板错误 :|入口快门超时。
E650226 PWB Conveying Error :| IN buffer-Center buffer PWB movement IN sensor ON detection error. |
Please remove it.”
传送基板错误 :|基板在入口缓冲区~中心缓冲区移动时,发现入口传感器ON|请取下基
板。
E650227 PWB Conveying Error :| Timeout in detecting IN sensor's turning OFF.”
传送基板错误 :|口传感器OFF超时。
E650232 PWB Conveying Error :| STOP sensor OFF detection time out error.”
传送基板错误 :|STOP传感OFF超时。
E650233 PWB Conveying Error :| C.OUT sensor OFF detection time out error.”
传送基板错误 :|C.OUT传感器OFF超时。
E650234 PWB Conveying Error : PWB conveying time out error of the center station. The process is forcibly
terminated. Please remove on the conveying route
传送基板错误 :|基板从入口区到中心区移动超过时间。
[Cause]
When inletting a PWB from the Input buffer to the center station, STOP sensor did not get ON even
though a certain amount of time has passed since the WAIT sensor of the Input buffer got OFF.
Usually, this error occurs when a PWB can not go through the INPUT buffer for some reason.
[Treatment]
1 If the PWB was NOT on the position where it is detected by WAIT and STOP sensors when
the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧ A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
2 If the belt was moving for a while after the PWB touched the stopper when the error occurred.
The STOP sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
STOP sensor in the 'Status' frame.
1)The sensitivity of the STOP sensor may be too low. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650235 PWB Conveying Error :| C.OUT sensor ON detection time out error.”
传送基板错误 :|C.OUT传感器 ON超时。
E650236 PWB Conveying Error :| C.OUT sensor ON detection error at Center stopper ON.”
传送基板错误 :|中心STOP ON时,发现C.OUT传感器ON错误。
E650237 PWB Conveying Error :| STOP sensor ON detection error at Center stopper ON.”
传送基板错误 :|中心STOP ON时,发现STOP传感器ON错误。
E650238 PWB Conveying Error :| When the PWB Vacuume is controlled. | it is Vacuume Sensor ON
detection time out.”
传送基板错误 :|基板吸取被控制时,真空传感器 ON超时。
E650239 PWB Conveying Error :| When the PWB Vacuume is controlled. | it is Vacuume Sensor OFF
detection time out.”
传送基板错误 :|基板吸取被控制时,真空传感器 OFF超时。
E650240 PWB Conveying Error :| Setting the Vacuum Table use is defferent | from setting the machine
setup.”
传送基板错误 :|真空台使用设置与机器设置不同。
E650242 PWB Conveying Error : PWB conveying error of the center station on the Entrance side. The
process is forcibly terminated. Please remove on the conveying route
传送基板错误 :|STOP1传感器OFF超时。
[Cause]
This error occurs if the STOP sensor on the center station on the Entrance side got OFF then ON
again, but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Entrance side to the center station on the Exit side.