The specifying of ATC position is abnormal. The data in the mac hine is broken or the versi on of the software that is installed on the machine is not correct. [Treatment] ‧Please turn off the power supply of your machi …

100%1 / 464
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
E610008 ATC(R) slide pate sensor is abnormal
ATC()滑板传感器异常。
[Cause]
The status of the slide plate ON sensor or OFF sensor of the right ATC slide plate is abnormal. The
slide plate ON sensor and OFF sensor got ON at the same time.
[Treatment]
Please select [Manual Control] from the menu bar, and then select [Control(C)] [Other(O)][ATC
Control(A)]. Set 'Control Unit' to 'right ATC', and select 'Slide plate Control(A)' from the 'Control
Item' frame' to open/close the slide plate. Please perform one of the treatments below according to the
result you get.
1. 'Slide plate ON sensor' and 'Slide plate OFF sensor' in the 'Status' displaying frame both get
ON/OFF.
‧Slide plate ON sensor or Slide plate OFF sensor, or both, is on the wrong position. There is a
possibility that the sensors are too close to each other, so widen the distance between the two.
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
2. Either one of 'Slide plate ON sensor' or 'Slide plate OFF sensor' in the 'Status' displaying frame is
always ON.
‧There is a possibility that the slide plate ON sensor or OFF sensor is broken. It could be that the
wiring came off the connector part, that a pin in the connector part is broken, that the wiring got cut
off, or the sensor itself is broken. Please examine the wiring and the connector. If any of them are
broken, you need to replace them with new ones.
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
E610009 Parameter for the head is not correct
Head 的参数不正确。
[Cause]
Head specifying is abnormal. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610010 The specified cylinder does not exist
指定圆筒不存在。
[Cause]
The specifying of ATC position is abnormal. The data in the machine is broken or the version of the
software that is installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610011 An error occurred when starting XY axes movement
XY 轴移动开始时发生错误
[Cause]
An error occurred when starting XY axes movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610012 An error occurred when starting X axis movement
X 轴移动开始时发生错误
[Cause]
An error occurred when starting X axis (left side) movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610013 An error occurred when starting XR axis movement
XR 轴移动开始时发生错误
[Cause]
An error occurred when starting X axis (right side) movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610014 An error occurred when starting Y axis movement
Y 轴移动开始时发生错误
[Cause]
An error occurred when starting Y axis movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610015 An error occurred when starting Z axis movement
Z 轴移动开始时发生错误
[Cause]
An error occurred when starting X axis (nozzle up-and-down axis) movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610016 An error occurred when starting Theta axis revolution
θ轴移动开始时发生错误。
[Cause]
An error occurred when starting Theta axis (nozzle revolving axis) revolution.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610017 An error occurred while XY axes are traveling
XY 轴移动时发生错误。
[Cause]
An error occurred while XY axes are traveling.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610018 An error occurred while X axis is traveling
X 轴移动时发生错误。
[Cause]
An error occurred while X axis (left side) is traveling.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610019 An error occurred while XR axis is traveling
XR 轴移动时发生错误。
[Cause]
An error occurred while X axis (right side) is traveling.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610020 An error occurred while Y axis is traveling
Y 轴移动时发生错误。
[Cause]
An error occurred while Y axis is traveling.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610021 An error occurred while Z axis is traveling
Z 轴移动时发生错误。
[Cause]