JUKI贴片机错误代码集合.pdf - 第69页
In 2030, Vacuum Calibration unit can be set only for R1 through R4. [Treatment] Please set to ATC of R1 through R4. E301051 “ Vacuum Cali bration can be et only for small-diameter nozzles. | (Setta ble ra nge : 1 - %d) ”…
E301045 “Vacuum Calibration can be set only for small-diameter nozzles.|(Settable range 1 - %d)”
“真空校准只对应小口径吸嘴。|(设置范围:1 - %d)”
E301046 “Only nozzle No. has been input. | Please specify nozzle types”
“只输入了吸嘴号。|请输入吸嘴种类。”
[Cause]
When you entered nozzle No. only, ATC nozzle allocation is not available.
[Treatment]
Please enter nozzle types.
E301047 “An error occurred while taking nozzles off. The process is discontinued”
“因取下吸嘴发生错误。|停止处理。”
[Cause]
This error occurs when the machine determines that a nozzle is still on the head despite that the
nozzle removal process took place.
[Treatment]
If the nozzle is not on the head, the laser might be too dirty to work properly. Please clean the laser.
Also, please check and see if the slide plate can slide properly or the sensor works properly with
Manual control. If the slide plate or the sensor does not work well, something might be broken. Please
take a note of the error No. and contact our technical service dept. for information.
E301048 “Vacuum Calibration unit position can not be measured”
“不能测量真空校准单元位置。”
[Cause]
The ATC which is set on the Vacuum Calibration unit can not be measured.
[Treatment]
When you need to measure the ATC, please UN-allocate then measure it.
E301049 “An error occurred while installing nozzles. | [Error occurs] %d| [Error No.] %d| [Error info] %d”
“安装吸嘴发生错误。|| [错误发生] %5d| [错误 No.] %5d| [错误详细] %5d||%s”
[Cause]
An error occurred while installing a nozzle when a nozzle change.
1): A code which tells where the error occurred.
2): Error code
3): Error details code
[Treatment]
Please take a note of the error No., and contact our technical service dept. for information.
E301050 “In 2030, Vacuum Calibration can be set for only R1 through R4”
“在 2030, 真空校准只对应从 R1 到 R4.”
[Cause]
In 2030, Vacuum Calibration unit can be set only for R1 through R4.
[Treatment]
Please set to ATC of R1 through R4.
E301051 “Vacuum Calibration can be et only for small-diameter nozzles. | (Settable range : 1 - %d)”
“对于该 ATC 不能设置真空校准。”
[Cause]
The Vacuum Calibration unit can not be set other ATC than the ATC of small nozzles.
|The maximum settable ATC number
[Treatment]
Please set the unit for the ATC of small nozzles.
E301052 “Any heads have not been specified”
“没有指定 Head。”
[Cause]
You did not specify a head to be measured.
[Treatment]
Please specify a head to measure.
E301053 “The Changer table can not be installed on the rear side since MTC/MTS have been selected”
“因 MTC/MTS 已被选择,不能把送料器台车安装在后侧。”
[Cause]
You can not use the changer table on the rear side when MTC or MTS is set to use.
[Treatment]
Please disable MTC or MTS when you use the changer table on the rear side.
E301054 “MTC/MTS can not be connected to 2000 series machines at the same time”
不能同时连接 MTC 和 MTS。”
[Cause]
MTC and MTS can not be set at the same time.
[Treatment]
Please disable one of them.
E301055 “An error on axes occurred”
“轴发生错误。”
[Cause]
An error occurred while axes were traveling.
[Treatment]
Please contact our technical service dept. for information.
E301056 “An error on XY axes occurred”
“XY 轴发生错误。”
[Cause]
An error occurred while XY axes were traveling.
[Treatment]
Please contact our technical service dept. for information.
E301057 “An error on Z axis occurred”
“Z 轴发生错误。”
[Cause]
An error occurred while Z axis was traveling.
[Treatment]
Please contact our technical service dept. for information.
E301058 “ Specified 508 nozzle has not been assigned yet. Please execute nozzle assignment”
”没有安装指定的 508 吸嘴。|请安装吸嘴。”
[Cause]
508 nozzle is necessary to auto-teach MTC shuttle pick position to the machine, but the 508 nozzle
has not been assigned yet..
[Treatment]
Please assign the 508 nozzle, then try auto-teaching.
E301059 “It was impossible to learn the height. | Please check out the vacuum value”
”不能取得高度。|请检查一下真空值。”
[Cause]
An abnormal matter happened while learning the height by vacuum.
[Treatment]
Please check and see if the vacuum pressure is correct.
E301060 “DTS/MTS can not be connected to 2000 series machines at the same time”
“不能同时连接 DTS 和 MTS。”
[Cause]
DTS and MTS can not be set at the same time.
[Treatment]
Please disable one of them.
E301061 “Feeder float detector can not be set only out position”
“传送带浮动传感器不能只安装在外侧。”
[Cause]
You can not use the outer feeder float detectors only.
[Treatment]
Please use the inner feeder float detectors only or use all the detectors at once.